Артикул: RX7683
Proportional pressure reducing valve, pilot-operated Z3DRE 10, Z3DREE 10
Доступно к заказу
Цена по запросу
И выбери подходящего.
Description
- Size 10
- Component series 1X
- Max. operating pressure 350 bar
- Flow, max. 120 l/min
Features
- Operation by rotatable proportional solenoid
- Sandwich plate design
- Porting pattern according to ISO 4401-05-05-0-05
- 4 pressure ratings
- Valve and control electronics from a single source
- External control electronics for type Z3DRE
- Linear command value pressure characteristic curve
- Integrated electronics (OBE) with type Z3DREE with little manufacturing tolerance of the command value pressure characteristic curve
Product description
load errorType code
| 01 | 02 | 02 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | ||
| Z | 3 | DRE | 10 | V | P | 2 | - | 1X | / | G24 | * |
| 01 | Sandwich plate valve | Z |
| 02 | 3-way version | 3 |
| 03 | Proportional pressure reducing valve | DRE |
| 04 | External control electronics | no code |
| Integrated electronics (OBE) | E | |
| 05 | Size 10 | 10 |
| 06 | Pilot-operated | V |
| 07 | Pressure reduction in channel P➁ | P |
| Preferred position of the proportional solenoid | ||
| 08 | The mating connector can be brought to the desired position when the nut was loosened, see "Dimensions". | 2 |
| 09 | Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions) | 1X |
| Pressure rating | ||
| 10 | Up to 50 bar | 50 |
| Up to 100 bar | 100 | |
| Up to 200 bar | 200 | |
| Up to 315 bar | 315 | |
| Pilot oil flow | ||
| 11 | Pilot oil supply for the directional valve from port P②, pilot oil return external for directional valve and Z3DRE(E) | Y |
| Pilot oil supply external for directional valve, pilot oil return external for directional valve and Z3DRE(E) | XY | |
| Pilot oil supply for the directional valve from port P②, pilot oil return internal for directional valve and external for Z3DRE(E) | L | |
| Pilot oil supply external for directional valve, pilot oil return internal for directional valve and external for Z3DRE(E); Directional valve without pilot oil supply | XL | |
| Pressure measuring port G1/4 | ||
| 12 | Without pressure measuring port | no code |
| With pressure measuring port (secondary pressure) | MS | |
| 13 | Direct voltage 24 V | G24 |
| Electrical connection | ||
| 14 | External control electronics: connector DIN EN 175301-803 | K4 2) |
| Integrated electronics: connector DIN EN 175301-804 | K31 2) | |
| Electrical interface | ||
| 15 | External control electronics | no code |
| Integrated electronics (OBE) | ||
| Command value 0 … 10 V | A1 | |
| Command value 4 … 20 mA | F1 | |
| Seal material (observe compatibility of seals with hydraulic fluid used, see "Technical data") | ||
| 16 | NBR seals | M |
| FKM seals | V | |
| 17 | Further details in the plain text | * |
| 1) | Valve contact surface (seal ring recess in the housing) |
| 2) | Mating connectors, separate order, see "Accessories" |
Technical data
general
| Type | Z3DRE | Z3DREE | |
| Size | 10 | ||
| Component series | 1X | ||
| Installation position | Preferred position of the proportional solenoid downward or horizontal | ||
| Weight | kg | 3.3 | 3.4 |
| Storage temperature range | °C | -20 … +80 | |
| Ambient temperature range | °C | -20 … +70 | -20 … +50 |
| Sine test according to DIN EN 60068-2-6 | 10 ... 2000 ... 10 Hz / maximum 10 g / 10 cycles | ||
| Noise test according to DIN EN 60068-2-64 | 20...2000 Hz, 10 gRMS, 24 h | ||
| Transport shock according to DIN EN 60068-2-27 | 15 g / 11 ms | ||
| MTTFD values according to EN ISO 13849 1) | Years | 150 | |
| 1) | Switch off "OBE" voltage supply. For further details, see data sheet 08012 |
hydraulic
| Type | Z3DRE | Z3DREE | ||
| Size | 10 | |||
| Maximum operating pressure | Port P① | bar | 350 | |
| Port P② | bar | 350 | ||
| Anschluss A | bar | 350 | ||
| Port B | bar | 350 | ||
| Port T | bar | 250 | ||
| Port X | bar | 350 | ||
| Port Y | separate and depressurized to the tank | |||
| Port L | separate and depressurized to the tank | |||
| Maximum set pressure in port P① | Pressure rating 50 bar | bar | 50 | |
| Pressure rating 100 bar | bar | 100 | ||
| Pressure rating 200 bar | bar | 200 | ||
| Pressure rating 315 bar | bar | 315 | ||
| Minimum set pressure 1) | bar | 12 | ||
| Maximum flow | l/min | 120 | ||
| Pilot flow range | l/min | 0.4 … 0.9 | ||
| Hydraulic fluid | see table "Hydraulic fluid" | |||
| Hydraulic fluid temperature range | °C | -20 … +80 | ||
| Viscosity range | mm²/s | 15 … 380 | ||
| Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 2) | Class 20/18/15 | |||
| Hysteresis 3) | % | < 6 | ||
| Repetition accuracy 3) | % | < ± 2 | ||
| Linearity 3) | % | ± 3.5 | ||
| Manufacturing tolerance of the command value pressure characteristic curve, related to the hysteresis characteristic curve | % | ± 5 3) | ± 1.5 4) | |
| Step response 5) | 10 ... 90% | ms | ≈ 140 | |
| 90 ... 10% | ms | ≈ 140 | ||
| 1) | In channel P① with command value zero |
| 2) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
| 3) | Of the maximum set pressure |
| 4) | Of the maximum set pressure, zero point calibration at the factory |
| 5) | Measured with 5 liters standing hydraulic fluid column at port P① |
| Hydraulic fluid | Classification | Suitable sealing materials | Standards | Data sheet | |
| Mineral oils | HL, HLP | NBR, FKM | DIN 51524 | 90220 | |
| Bio-degradable | Insoluble in water | HETG | NBR, FKM | ISO 15380 | 90221 |
| HEES | FKM | ||||
| Soluble in water | HEPG | FKM | ISO 15380 | ||
| Flame-resistant | Water-free | HFDU (glycol base) | FKM | ISO 12922 | 90222 |
| HFDU (ester base) | FKM | ||||
| HFDR | FKM | ||||
| Containing water | HFC (Fuchs: Hydrotherm 46M, Renosafe 500; | NBR | ISO 12922 | 90223 | |
| Important information on hydraulic fluids:
| |||||
electrical
| Type | Z3DRE | Z3DREE | ||
| Minimum solenoid current | mA | 100 | ||
| Maximum solenoid current | mA | 1600 | ||
| Solenoid coil resistance | Cold value at 20 °C | Ω | 5.5 | |
| Maximum hot value | Ω | 8.05 | ||
| Duty cycle | % | 100 | ||
| Power supply | Nominal voltage | VDC | 24 | |
| Lower limit value | VDC | 21 | ||
| Upper limit value | VDC | 35 | ||
| Current consumption | A | < 1.5 | ||
| Required fuse protection | 2, time-lag | |||
| Inputs | Voltage | V | 0 … 10 | |
| Current | mA | 4 … 20 | ||
| Outlet | Actual current value | 1 mV ≙ 1 mA | ||
| Protection class according to DIN EN 60529 | IP65 (If a suitable and a correctly mounted mating connector are used.) | |||
(For applications outside these values, please consult us!)
Diagrams/characteristic curves
(measured with HLP46, ϑOil = 40 ±5 °C)
Reduced pressure at port P① dependent on the command value (manufacturing tolerance)

| 1) | In order to be able to adjust several valves to the same characteristic curve, the manufacturing tolerance can - with version "Z3DRE" - be changed at the external amplifier (see "Accessories") using the command value attenuator "G". In this connection, do not set the pressure higher than the maximum set pressure of the pressure rating with command value 100%. |
Pressure at port P① dependent on the command value (with a flow of 0 l/min)
Pressure rating 50 bar

Pressure rating 100 bar

Pressure rating 200 bar

Pressure rating 315 bar

Pressure at port P① dependent on the flow
Pressure rating 50 bar

Pressure rating 100 bar

Pressure rating 200 bar

Pressure rating 315 bar

Minimum set pressure dependent on the flow with command value zero

Δp-qV characteristic curves

Symbols/Circuit diagrams
External control electronics "Z3DRE"
Version “XY"

Version “XL"

| 1) | Pressure measuring port "MS" as example for all types |
Version “Y”

Version “L”

Integrated electronics (OBE) "Z3DREE"
Version “XY"

Version “XL"

Version “Y”

Version “L”

| ① | component side |
| ② | plate side |
Notices:
- Representation according to DIN ISO 1219-1.
- Deviating from ISO 4401, port T is in this data sheet called TA, port T1 is called TB.
Electrical connection
load errorDimensions
load errorDownloads
| Proportional pressure reducing valve, pilot-operated Data Sheet | RE29282 | 2019-02-01 | English | PDF | 869k Product Groups: Pilot operated Type Z3DRE and Z3DREE |