Артикул: RX7669
Proportional pressure reducing valve, pilot-operated 3DRE(M)
Доступно к заказу
Цена по запросу
И выбери подходящего.
Description
- Size 10, 16
- Component series 7X
- Maximum set pressure 315 bar
- Maximum flow 300 l/min
Features
- 3-way version
- Operation by means of proportional solenoid with rotatable coil
- For subplate mounting
- Porting pattern according to ISO 4401
- Maximum pressure limitation, optional
- Valve and control electronics from a single source
- External control electronics
- Linear command value pressure characteristic curve
Product description
Valves of type 3DRE(M) are electrically pilot-operated 3-way pressure reducing valves with pressure limitation of the actuator.
They are used for reduction (P to A) and limitation (A to T) of a system pressure.
Set-up
The valves consist of two main assemblies:
- Pilot control valve (1) with proportional solenoid (2), optionally with maximum pressure limitation (15)
- Main valve (3) with main control spool (4)
Function
- Command value-dependent setting of the pressure to be reduced in port A via the pilot control valve (1).
- With depressurized port P, the springs (5) and (6) hold the main control spool (4) in its central position. In this way, a start-up jump at the actuator is prevented.
- Pilot fluid flows from bore (7) via the flow controller (8), via the control chamber (11) to the throttle gap (9), via line (10) to port Y. This connection is to be led into the tank at zero pressure.
Pressure reduction
- Build-up of the pilot pressure in the control chamber (11) as function of the command value.
- Pressure build-up in the spring chamber (13) via nozzle (12) and movement of the main control spool (4) to the right. Hydraulic fluid flows from P to A.
- The actuator pressure in port A is available in the spring chamber (14).
- Increase in the pressure in port A to the set pressure of the pilot control valve (1) leads to the movement of the main spool (4) to the left. Pressure in port A is almost identical with the set pressure at the pilot control valve (1).
Pressure limitation
- If the pressure in port A exceeds the set pressure of the pilot control valve (1), the main control spool (4) is moved further to the left.
- This opens the connection from A to T and limits the pressure pending in port A to the set command value.
Type 3DREM
For hydraulic protection against an inadmissibly high electric control current at the proportional solenoid, which imperatively results in increased pressures in port A, you can optionally install a spring-loaded pressure relief valve as maximum pressure limitation (15). The maximum pressure limitation is pre-set, referred to the relevant pressure rating (see "Technical data").
Pilot oil supply
Size 10
Size 16
1 | Plug screw M6 according to DIN 906, wrench size 3 - Pilot oil return |
2 | Main valve |
3 | Cover |
Pilot oil supply | Pilot oil return | |
External | 1 closed | External |
Internal | 1 open |
Version "XY"
The pilot oil is supplied externally from a separate pilot circuit. The pilot oil return is implemented externally via port Y into the tank.
Version "Y"
The pilot oil supply is implemented internally from channel P of the main valve. The pilot oil return is implemented externally via port Y into the tank. In the subplate, port X is closed.
Type code
01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | ||
3DRE | P | – | 7X | / | G24 | K4 | * |
01 | Proportional pressure reducing valve in 3-way version, pilot-operated | 3DRE |
02 | Without maximum pressure limitation | no code |
With maximum pressure limitation | M | |
03 | Size 10 | 10 |
Size 16 | 16 | |
04 | Subplate mounting | P |
05 | Component series 70 … 79 (70 … 79: unchanged installation and mounting dimensions) | 7X |
Pressure rating | ||
06 | Up to 50 bar | 50 |
Up to 100 bar | 100 | |
Up to 200 bar | 200 | |
Up to 250 bar (NG16 only) | 250 | |
Up to 315 bar (NG10 only) | 315 | |
07 | Internal pilot oil supply, external pilot oil return | Y |
External pilot oil supply, external pilot oil return | XY | |
Power supply | ||
08 | Direct voltage 24 V | G24 |
Coil | ||
09 | 1600 mA | no code |
800 mA | -8 | |
Electrical connection | ||
10 | Without mating connector; connector DIN EN 175301-803 | K4 |
Seal material (observe compatibility of seals with hydraulic fluid used, see "Technical data") | ||
11 | NBR seals | M |
FKM seals | V | |
12 | Further details in the plain text | * |
Technical data
general
Type | 3DRE(M) | ||
Size | 10 | 16 | |
Installation position | any, preferably horizontal | ||
Weight | kg | 7.5 | 10.3 |
Storage temperature range | °C | -20 … +80 | |
Ambient temperature range | °C | -20 … +70 |
hydraulic
Type | 3DRE(M) | |||
Size | 10 | 16 | ||
Maximum operating pressure | Port P | bar | 350 | 315 |
Anschluss A | bar | 315 | 250 | |
Port T | bar | 315 | 250 | |
Port X | bar | 350 | 315 | |
Port Y | separate and depressurized to the tank | |||
Maximum set pressure in port A | Pressure rating 50 bar | bar | 50 | |
Pressure rating 100 bar | bar | 100 | ||
Pressure rating 200 bar | bar | 200 | ||
Pressure rating 250 bar | bar | - | 250 | |
Pressure rating 315 bar | bar | 315 | - | |
Minimum set pressure 1) | bar | < 5 | < 4 | |
Maximum pressure limitation 2) | Pressure rating 50 bar | bar | 70 | |
Pressure rating 100 bar | bar | 130 | ||
Pressure rating 200 bar | bar | 230 | ||
Pressure rating 250 bar | bar | - | 270 | |
Pressure rating 315 bar | bar | 350 | - | |
Maximum flow | l/min | 125 | 300 | |
Pilot flow | l/min | 1.1 | ||
Hydraulic fluid | see table "Hydraulic fluid" | |||
Hydraulic fluid temperature range | °C | -20 … +80 | ||
Viscosity range | mm²/s | 15 … 380 | ||
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 3) | Class 20/18/15 | |||
Hysteresis 4) | % | ± 3 | ||
Repetition accuracy 4) | % | < ± 2 | ||
Linearity 4) | % | ± 3.5 | ||
Manufacturing tolerance of the command value pressure characteristic curve 5) | at command value 20 % | % | < ± 1.5 | |
at command value 100 % | % | < ± 5 | ||
Step response Tu + Tg 6) | 10 ... 90% | ms | < 140 |
1) | In channel A without flow, with command value 0 (see characteristic curves) |
2) | Continuously adjustable, set at the factory |
3) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
4) | Of the maximum set pressure |
5) | Of the maximum set pressure; related to the hysteresis characteristic curve; pressure increasing |
6) | Measured with standing hydraulic fluid column, 1.0 L at port A |
Hydraulic fluid | Classification | Suitable sealing materials | Standards | Data sheet | |
Mineral oils | HL, HLP, HLPD, HVLP, HVLPD | NBR, FKM | DIN 51524 | 90220 | |
Bio-degradable | Insoluble in water | HETG | NBR, FKM | ISO 15380 | 90221 |
HEES | FKM | ||||
Soluble in water | HEPG | FKM | ISO 15380 | ||
Flame-resistant | Water-free | HFDU (glycol base) | FKM | ISO 12922 | 90222 |
HFDU (ester base) | FKM | ||||
HFDR | FKM | ||||
Containing water | HFC (Fuchs: Hydrotherm 46M, Renosafe 500; | NBR | ISO 12922 | 90223 | |
Important information on hydraulic fluids:
|
electrical
Version | "G24" | "G24-8" | ||
Minimum solenoid current | mA | ≤ 100 | ||
Maximum solenoid current | mA | 1600 ±10 % | 800 ±5 % | |
Solenoid coil resistance | Cold value at 20 °C | Ω | 5.5 | 20.6 |
Solenoid coil resistance | Maximum hot value | Ω | 8.05 | 33 |
Duty cycle | % | 100 |
(For applications outside these values, please consult us!)
Diagrams/characteristic curves
(measured with HLP46, ϑOil = 40 ±5 °C)
Pressure in port A dependent on the command value (manufacturing tolerance); without flow
1) | In order to be able to adjust several valves to the same characteristic curve, the manufacturing tolerance can be changed at the external amplifier (see "Accessory") using the command value attenuator "G". In this connection, do not set the pressure higher than the maximum set pressure of the pressure rating with command value 100 %. |
Pressure in port P depending on the command value
– Comparison "G24" and "G24-8"; pressure rating 200 bar
(with amplifier VT-VSPA1-1-1X, 800 mA coil)
Pressure in port P depending on the command value
– Current drop with version "G24-8"
(increasing ambient temperature, 24 V, 100 % duty cycle)
Notices:
- Valve body and hydraulic fluid temperature-compensated; large temperature differences may lead to differing values.
- With version "G24-8", the solenoid current drops in case of increased temperature. Thus, the set pressure differs accordingly.
Size 10
Pressure in port A dependent on the command value (flow = 0 l/min)
Pressure rating 50 bar
Pressure in port A dependent on the command value (flow = 0 l/min)
Pressure rating 100 bar
Pressure in port A dependent on the command value (flow = 0 l/min)
Pressure rating 200 bar
Pressure in port A dependent on the command value (flow = 0 l/min)
Pressure rating 315 bar
Δp-qV characteristic curves
Pressure in port A dependent on the flow
Minimum set pressure dependent on the flow (Command value 0)
Notice:
Valve body and hydraulic fluid temperature-compensated; large temperature differences may lead to differing values.
Size 16
Pressure in port A dependent on the command value (flow = 0 l/min)
Pressure rating 50 bar
Pressure in port A dependent on the command value (flow = 0 l/min)
Pressure rating 100 bar
Pressure in port A dependent on the command value (flow = 0 l/min)
Pressure rating 200 bar
Pressure in port A dependent on the command value (flow = 0 l/min)
Pressure rating 250 bar
Δp-qV characteristic curves
Pressure in port A dependent on the flow
Minimum set pressure dependent on the flow (Command value 0)
Notice:
Valve body and hydraulic fluid temperature-compensated; large temperature differences may lead to differing values.
Symbols/Circuit diagrams
"3DRE…Y…" | "3DREM…Y…" | "3DRE…XY…" | "3DREM…XY…" |
Electrical connection
load errorDimensions
load errorDownloads
Proportional pressure reducing valve, pilot-operated Data Sheet | RE29286 | 2020-01-01 | English | PDF | 984k Product Groups: Pilot operated Type 3DRE(M) and 3DRE(M)E |
Мы предлагаем следующие способы доставки товара:
Самовывоз из пункта выдачи
Самостоятельное получение заказа в пункте выдачи. Дата и время получения заранее согласуется с менеджером магазина.
Отгрузка товара юридическим лицам осуществляется только при наличии печати или правильно оформленной и заполненной доверенности, наличии паспорта получателя.
Курьерская доставка по Москве
Доставка по адресу покупателя или до пункта приема транспортной компании в г. Москве. Дата и время доставки заранее согласуется с менеджером магазина.
Доставка транспортной компанией по России
Доставка транспортной компанией по России до пункта выдачи транспортной компании или до конечного адреса покупателя.
Мы предлагаем следующие способы оплаты товара:
Оплата наличными
Оплата за наличный расчет для физических и юридических лиц. После внесения денежных средств Покупатель подписывает товаросопроводительные документы и получает кассовый чек.
Безналичная оплата
Мы работаем с физическими и юридическими лицами за безналичный расчёт со 100% предоплатой с оформлением всех предусмотренных законодательством документов. Счёт на оплату направляется Покупателю на электронную почту после запроса счета через форму на сайте либо по электронной почте. Цена на заказанный товар действительна в течение 2 дней с момента оформления Заказа.
Электронные способы
Оплата Заказа электронными способами, в т.ч. банковскими картами. Оплата Заказа данным способом доступна запросом ссылки на оплату у нашего менеджера.
Если у вас возникнут вопросы по оформлению заказа, вы можете обратиться к нам, позвонив по телефону +7 495 137-07-02 или связавшись по электронной почте sale@boschrexroth-russia.ru. Мы гарантируем оперативный ответ на ваш запрос и предоставление наилучших условий от официального поставщика Bosch Rexroth.
Мы предоставляем официальную гарантию на всю поставляемую продукцию Bosch Rexroth.
Гарантийный сервис включает в себя:
- Приемку продукции в сервисный центр для выполнения диагностики дефекта.
- Ремонт продукции.
- Доставку продукции до объекта заказчика.
- Телефон: +7 495 137-07-02
- E-mail: support@boschrexroth-russia.ru
Для расчета коммерческого предложения или получения счета на поставку оборудования и программного обеспечения Bosch Rexroth оставьте заявку в форме ниже или свяжитесь с отделом продаж по телефону +7 495 137-07-02 или электронной почте sale@boschrexroth-russia.ru. Мы гарантируем оперативный ответ на ваш запрос и предоставление наилучших условий от официального поставщика Bosch Rexroth.
Специалист по решениям Bosch Rexroth:
- Окажет профессиональную консультацию.
- Сообщит вашу цену на продукцию.
- Сообщит информацию об актуальных акциях и скидках.
- Подскажет ближайшее к вам отделение с наличием нужной продукции.
- Согласует с вами возможную дату и время доставки.
Нет отзывов об этом товаре.