Directional control valves, direct operated, with electrical position feedback and integrated flow control (IFB Multi-Ethernet) 4WRPQ
Доступно к заказу
Цена по запросу
И выбери подходящего.
Description
- Size 10
- Component series 3X
- Maximum operating pressure 280 bar
- Nominal flow 80 l/min
Features
- Open
- Integrated, digital flow controller (IFB Multi-Ethernet)
- Bus connection/service interface (Sercos, EtherCAT, EtherNet/IP, PROFINET RT, POWERLINK, VARAN) - Safe
- Internal safety function (can be used up to category 4/PL e according to EN13849-1)
- CE conformity according to EMC Directive 2014/30/EU
Product description
General information
The IFB Multi-Ethernet valve (Integrated Fieldbus) is a digital directional control valve with integrated flow controller, load-independent.
The following operating modes are possible:
- Valve direct control
- Flow control
- Pressure/force control
- Pressure control/volume substitutional
- Torque/force control/flow
- Pressure control/valve direct control substitutional
- Substitutional control (flow – pressure/force); pQ function (flow-controlled)
Communication is done via the digital Multi-Ethernet interface (X7E1 or X7E2) only. The following data may be exchanged:
- Command values
- Actual values
- Configuration and setting of the system control parameters
- Status messages, faults or warnings
Set-up
The directional control valve with IFB Multi-Ethernet electronics mainly consists of:
- Main housing with control spool (1)
- Control electronics with integrated fieldbus (3)
- Connector, voltage supply, safety shut-down (XH1)
- Ethernet interfaces (X7E1, X7E2)
- Pressure sensor sandwich plate (4)
- Stroke solenoid (2.1)
- Control solenoid with electrical position feedback (2.2)
Flow control
The integrated electronics (OBE) enables load-independent control of the flow at positive command value by means of the two integrated pressure sensors in ports P and A. At negative command value, the flow is controlled from P to B.
Safety function (only symbol Q5-)
The integrated electronics (OBE) of the valve enable additional shut-off of a channel according to EN 13849-1 in both directions (depending on the symbol, the valve can be considered as safely shut-off).
When using symbol V, the valve cannot be used in a safety-relevant manner according to EN 13849-1 while enable acknowledgment always remains 0.
Thanks to the two control solenoids (enable pin D and E, low signal) at the connector (XH1), direction-dependent shut-off is enabled. The control spool of the valve is in spring-centered central position for this purpose (fail-safe position).
Enable acknowledgment pin C for solenoid A and pin F for solenoid B are "high". By connecting both control solenoids (enable pin D and E, high signal), the valve can be controlled by a command value presetting (command value positive, solenoid B or command value negative, solenoid A).
Enable acknowledgment pin C for solenoid A and pin F for solenoid B are "low".
Separate shut-off of solenoid A or solenoid B will moreover allow for the direction-dependent activation or shut-off of the drive.
Notice for safe shut-off according to EN 13849-1 (Enable acknowledgment)
The enable acknowledgment is not set (pin C and F):
- Regular operation, enable active:
- Enable at pin D clears enable acknowledgment at pin C, enable at pin E clears enable acknowledgment at pin F.
- For failure of supply voltage.
- In case of a cable break (the integrated electronics (OBE) will de-energize both control solenoids and the control spool will move to the spring-centered central position).
- If the control spool is not in a hydraulically safe position (insufficient safety overlap of the control spool or safe position is not reached).
Monitoring
The digital control electronics enable comprehensive monitoring functions/error detection including:
- Undervoltage
- Communication error
- Cable break for analog sensor inputs
- Monitoring of the microcontroller (watchdog)
- Temperature of the integrated electronics
IndraWorks DS PC program
To implement the project planning task and to parameterize the valve, the user may use the IndraWorks DS engineering tool (see accessories):
- Project planning
- Parameterization
- Commissioning
- Diagnosis
- Comfortable administration of all data on a PC
- PC operating systems: Windows 10
Notices:
- When using symbol V, the enable inputs (enable pin D and E) may only be activated and deactivated together.
- For all other symbols, a unilateral shut-off will cause reduced performance data.
- 4/3 directional control valves do not have a leakage-free basic locking when deactivated. Leakage must be considered when designing the drive.
- Valve type 4WRPQ (symbol Q5-) can be used as shut-off element cat. 3 or 4 (up to PL e according to EN 13849-1). For both categories, an additional shut-off element is required to achieve a two-channel shut-off. For further information on the safety application, see operating instructions 29391-B.
- At a flow command value of 0, the specified flow control tolerance also applies.
Type code
01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | |||
4 | WRP | Q | 10 | 80 | S | 3X | / | / | G | F | 24 | / | D9 | 0 | * |
01 | 4 main ports | 4 |
02 | High-response directional valve, direct operated | WRP |
03 | With integrated digital flow controller | Q |
04 | Size 10 | 10 |
05 | Symbols; for the possible version, see "Symbols/Circuit diagrams" | |
Rated flow (Δp = 5 bar/control edge) | ||
06 | 80 l/min | 80 |
Flow characteristic | ||
07 | Progressive | S |
08 | Component series 30 … 39 (30 … 39: unchanged installation and connection dimensions) | 3X |
Seal material (observe compatibility of seals with hydraulic fluid used, see "Technical data") | ||
09 | NBR seals | M |
FKM seals | V | |
Pressure sensor (pressure rating) | ||
10 | Pressure rating 280 bar | G |
Internal pressure sensor (position) | ||
11 | In port A, B and P | F |
12 | Supply voltage 24 V | 24 |
Ethernet interface | ||
13 | EtherNet/IP | E |
PROFINET RT | N | |
Sercos | S | |
EtherCAT (Profil CANopen) | T | |
POWERLINK (CANopen profile) | W | |
VARAN | V | |
Connector | ||
14 | Voltage supply, enable acknowledgement | D9 |
Pressure sensor interface | ||
15 | Without interface | 0 |
16 | Further details in the plain text | * |
Technical data
general
Size | 10 | |
Installation position | any | |
Earth | kg | 9.8 |
Storage temperature range 1) | °C | +10 … +40 |
Maximum storage time 2) | yrs | 1 |
Ambient temperature range | °C | -20 … +60 |
Sine test according to DIN EN 60068-2-6 | 10 ... 2000 Hz / maximum 10 g / 10 cycles / 3 axes | |
Noise test according to DIN EN 60068-2-64 | 20 ... 2000 Hz / 10 gRMS / 30 g peak / 30 min / 3 axes | |
Transport shock according to DIN EN 60068-2-27 | 15 g / 11 ms / 3 shocks / 3 axes | |
Maximum relative humidity 3) | % | 95 |
MTTFD values according to EN ISO 13849 4) | Years | 150 |
Conformity | CE according to EMC directive 2014/30/EU tested according EN 61000-6-2 and EN 61000-6-3 RoHS directive 2011/65/EU REACH ordinance (EC) no. 1907/2006 |
1) | With UV protection |
2) | If the storage conditions are observed; refer to the operating instructions 07600-B |
3) | No condensation |
4) | For further details, see data sheet 08012 |
hydraulic
Maximum operating pressure | Port P | bar | 280 |
Anschluss A | bar | 280 | |
Port B | bar | 280 | |
Port T | bar | 200 | |
Nominal flow 1) | l/min | 80 | |
Hydraulic fluid | see table "Hydraulic fluid" | ||
Hydraulic fluid temperature range 2) | °C | -20 … +70 | |
Viscosity range | Maximum admissible | mm²/s | 10 … 800 |
Recommended | mm²/s | 20 … 100 | |
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 3) | Class 18/16/13 |
1) | Δp = 5 bar/control edge; flow with deviating Δpsee formula. |
2) | Flown-through |
3) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. |
Notice:
The specified technical data were measured with HLP46 and ϑÖl = 40 ±5 °C.
Hydraulic fluid | Classification | Suitable sealing materials | Standards | Data sheet | |
Mineral oils | HL, HLP, HLPD, HVLP, HVLPD | NBR, FKM | DIN 51524 | 90220 | |
Bio-degradable | Insoluble in water | HETG | FKM | ISO 15380 | 90221 |
HEES | FKM | ||||
Soluble in water | HEPG | FKM | ISO 15380 | ||
Flame-resistant | Water-free | HFDU (glycol base) | FKM | ISO 12922 | 90222 |
HFDU (ester base) | FKM | ||||
HFDR | FKM | ||||
Containing water | HFC (Fuchs: Hydrotherm 46M, Renosafe 500; | NBR | ISO 12922 | 90223 | |
Important information on hydraulic fluids:
|
static / dynamic (direct valve control)
Hysteresis | % | < 0.25 |
Response sensitivity | % | < 0.05 |
Range of inversion | % | < 0.05 |
Manufacturing tolerance | % | < 10 |
Temperature drift 1) | %/10 K | Zero shift <0.25 |
Pressure drift | %/100 bar | Zero shift <0.2 |
Zero point calibration (set in the plant) | % | ± 1 |
1) | Temperature range 20 °C ... 80 °C |
static / dynamic (flow control)
Flow accuracy 1) | l/min | 180±9 |
1) | Accuracy tolerance of controlled flow/recommended maximum flow |
electrical
Power supply 1) | Nominal voltage | VDC | 24 |
Lower limit value | VDC | 18 | |
Upper limit value | VDC | 36 | |
Maximum admissible residual ripple 2) | Vpp | 2.5 | |
Relative duty cycle 3) | % | 100 | |
Current consumption | Maximum 4) | A | 2.8 |
Impulse current | A | 4 | |
Required fuse protection | A | 4, time-lag | |
Maximum power consumption | W | 65 | |
Protection class according to EN 60529 | IP65 (If a suitable and a correctly mounted mating connector are used.) | ||
AD/DA resolution | Analog inputs | bits | 12 |
Protective earthing conductor and screening | See connector pin assignment (CE-compliant installation), "Electrical connection" | ||
Adjustment | Calibrated in the plant | ||
Parameterization interface | Ethernet | ||
Scan time pressure and force controller (minimum) | ms | 0.5 | |
Booting time | s | < 15 | |
Conformity | CE according to EMC directive 2014/30/EU tested according EN 61000-6-2 and EN 61000-6-3 |
1) | Voltage limit values must be observed directly at the connector of the valve (observe line length and cable cross-section). |
2) | Observe the absolute limit values of the supply voltage. |
3) | Continuous operation |
4) | The maximum current consumption will increase when using the sensor inputs or the switching output according to the external load |
electrical, integrated electronics (OBE)
Switching input Enable XH1 | Quantity |
| 2 |
Low level | V | -3 ... +5 | |
High level | V | 15 ... UB | |
Current consumption at high level | mA | <15 | |
Reference potential |
| Pin B | |
Switching output Enable acknowledgment XH1 | Quantity |
| 2 |
Low level | V | 0 ... 3 | |
High level | V | 15 ... UB | |
Maximum current carrying capacity | mA | 50 (short-circuit-proof) | |
Signal delay time | ms | see operating instructions 29391-B | |
Reference potential |
| Pin B |
(For applications outside these values, please consult us!)
Diagrams/characteristic curves
(measured with HLP46, ϑOil = 40 ±5 °C)
Direct valve control
Pressure-signal characteristic curve
Symbol V
Flow/signal function (nominal flow 80 l/min at Δp = 5 bar/control edge)
Symbol V
Flow/signal function (nominal flow 80 l/min at Δp = 5 bar/control edge)
Symbol Q5-
Transition function with stepped electric input signals
Symbol V
Transition function with stepped electric input signals
Symbol Q5-
Frequency response
Symbol V
Frequency response
Symbol Q5-
Flow/load function with maximum valve opening (tolerance ±10 %)
Rated flow 80 l/min, summated edge
Notice:
Typical characteristic curves which are subject to tolerance variation.
Flow control
Flow deviation (tolerance ±4 l/min)
Single edge (supply flow edge qV command = 180 l/min)
Accuracy tolerance of controlled flow/recommended maximum flow
Default value 180 l/min
Notices:
- The maximum possible flow is specified in parameter "maximum flow" (P-0-2875.0.3). The default value is defined by the performance data of the valve (see parameter description 30330-PA).
- Observe the limitations of use of the valve under "Flow/load function with maximum valve opening".
Symbols/Circuit diagrams
Notice:
Representation according to ISO 1219-1.
Hydraulic interim positions are shown by dashes.
Electrical connection
Block diagram / pin assignment
1) | Not with "VARAN" |
2) | Safe deactivation with simultaneous use of enable acknowledgment |
Detailed description of the safety function:
After both enable signals have been removed, both output stages, and thus the solenoid A and B of the valve, are internally separated from the available supply voltage. The enable acknowledgment will only be activated for shut-off of A and B separately after the safe valve spool position has been achieved.
For a detailed description of the safety function, refer to the operating instructions 29391-B.
Connector pin assignment XH1, 6-pole + PE according to DIN 43563
Pin | Assignment of interface D9 |
A | 24 VDC supply voltage 1) |
B | GND (reference for pin A, C, D, E, F) |
C | Enable acknowledgment 24 VDC (Imax 50 mA; high ≥ 15 V; low < 2 V); Flow from P→A 2) |
D | Enable input 24 VDC (high ≥ 15 V; low < 2 V); Flow from P→A |
E | Enable input 24 VDC (high ≥ 15 V; low < 2 V); Flow from P→B |
F | Enable acknowledgment 24 VDC (Imax 50 mA; high > 15 V; low < 2 V); Flow from P→B 2) |
PE | Functional ground (directly connected to the valve housing) |
1) | A load increases the current consumption on pin A |
2) | Enable acknowledgement is issued only if the valve has safely switched off according to EN 13849-1, see operating instructions 29391-B. |
Connector pin assignment: M12 x 1, 4-pole, coding D, socket (for Ethernet interfaces "X7E1" and "X7E2")
Pin | Assignment |
1 | TxD + |
2 | RxD + |
3 | TxD - |
4 | RxD - |
5 | Not assigned |
Notices:
- Reference potential for all signals : GND
- We recommend connecting the shields on both sides via the metal housings of the plug-in connectors.
LED displays
LED | Interface | Sercos | EtherNet/IP | EtherCAT | PROFINET RT | POWERLINK | VARAN |
MS | Electronic module | Module Status | Module Status | Module Status | Module Status | Module Status | Module Status |
NS | S | Network status and others | Network status and others | Network status and others | Status/Error | Network status and others | |
L1 | X7E1 | Link and others | Link and others | Link/Activity | Link and others | Link/Data Activity | Link and others |
S1 | Activity and others | Activity and others | not used | Activity and others | not used | Activity and others | |
L2 | X7E2 | Link and others | Link and others | Link/Activity | Link and others | Link/Data Activity | not used |
S2 | Activity and others | Activity and others | not used | Activity and others | not used | not used | |
PWR | XH1 | Power | Power | Power | Power | Power | Power |
Displays of the Status LEDs
Module status (LED MS) | Display status |
Off | No voltage supply |
Green-red, flashing | Initialization |
Green, flashing | Drive ready for operation |
Green | Drive active |
Orange, flashing | Warning |
Red, flashing | Error |
Green, rapidly flashing | Firmware must be loaded |
Power LED (LED PWR) | Display status |
Off | No voltage supply |
Green | Operation |
Link-LED (LED L1) | Display status |
Permanently lit | Cable plugged in, connection established |
Activity-LED (LED S1) | Display status |
Flashing | Data sent/received |
Notices:
- For the connection to the M12 sockets, we recommend using self-locking mating connectors.
- Module status LED MS relates to the electronics module.
- The network status LED NS indicates the status of the control communication, see application description 30338-FK.
- LEDs L1, S1, L2 and S2 relate to interfaces "X7E1" and "X7E2"
- For a detailed description of the diagnosis LEDs, please refer to the functional description "Rexroth HydraulicDrive HDx".
- Function is only available after start-up of the electronics.
Dimensions
Dimensions in mm
Required surface quality of the valve contact surface |
1 | Name plate |
2 | Valve housing |
3 | Integrated digital control electronics |
4 | Identical seal rings for ports A, B, P and T (T1) |
5 | Control solenoid with position transducer |
6 | Machined valve contact surface; Porting pattern according to ISO 4401-05-04-0-05 |
7 | Stroke solenoid |
8 | Mating connectors, separate order, see "Accessories" and datasheet 08006. |
9 | Space required to remove plug-in connector |
10 | Multi Ethernet interface X7E1 |
11 | Multi Ethernet interface X7E2 |
Notice:
The dimensions are nominal dimensions which are subject to tolerances.
Valve mounting screws (separate order)
Size | Quantity | Hexagon socket head cap screws | Material number |
10 | 4 | ISO 4762 - M6 x 80 - 10.9-CM-Fe-ZnNi-5-Cn-T0-H-B (Friction coefficient μtotal = 0.09 … 0.14) Tightening torque MA = 13 Nm ±10 % | R913049927 |
or | |||
4 | ISO 4762 - M6 x 80 - 10.9 Tightening torque MA = 13 Nm ±10 % | Not included in the Rexroth delivery range |
Notice:
The tightening torque of the hexagon socket head cap screws refers to the maximum operating pressure.
Subplates (separate order) with porting pattern according to ISO 4401-05-04-0-05, see data sheet 45100.
Project planning information
Project planning and maintenance instructions
- The supply voltage must be permanently connected, as otherwise bus communication is not possible.
- If electro-magnetic interference is to be anticipated, suitable measures must be taken to ensure the function (depending on the application, e.g. shielding, filtration).
- The devices have been tested in the plant and are supplied with default settings.
- Only complete devices can be repaired. Repaired devices are returned with default settings. User-specific settings will not be applied. The machine end-user will have to retransfer the corresponding user parameters.
Accessories
Protective cap
Denomination | Material number | |
Protective cap | R901075563 |
Mating connectors for valves with round connector, 6-pole + PE
7P Z31
Mating connectors for valves with round connector, 6-pole + PE
7P Z31
- For valves with round connector according to EN 175201-804, 6-pole + PE as well as 6-pole, compatible with VG 95328
Mating connectors for valves with round connector, 6-pole + PE, shielded, with assembled connection line
7P Z31 +
Mating connectors for valves with round connector, 6-pole + PE, shielded, with assembled connection line
7P Z31 +
- For valves with round connector according to EN 175201-804, 6-pole + PE as well as 6-pole, compatible with VG 95328
Ordering codes
Currently 'Generic Selector' is not available. Please try again later.Downloads
Мы предлагаем следующие способы доставки товара:
Самовывоз из пункта выдачи
Самостоятельное получение заказа в пункте выдачи. Дата и время получения заранее согласуется с менеджером магазина.
Отгрузка товара юридическим лицам осуществляется только при наличии печати или правильно оформленной и заполненной доверенности, наличии паспорта получателя.
Курьерская доставка по Москве
Доставка по адресу покупателя или до пункта приема транспортной компании в г. Москве. Дата и время доставки заранее согласуется с менеджером магазина.
Доставка транспортной компанией по России
Доставка транспортной компанией по России до пункта выдачи транспортной компании или до конечного адреса покупателя.
Мы предлагаем следующие способы оплаты товара:
Оплата наличными
Оплата за наличный расчет для физических и юридических лиц. После внесения денежных средств Покупатель подписывает товаросопроводительные документы и получает кассовый чек.
Безналичная оплата
Мы работаем с физическими и юридическими лицами за безналичный расчёт со 100% предоплатой с оформлением всех предусмотренных законодательством документов. Счёт на оплату направляется Покупателю на электронную почту после запроса счета через форму на сайте либо по электронной почте. Цена на заказанный товар действительна в течение 2 дней с момента оформления Заказа.
Электронные способы
Оплата Заказа электронными способами, в т.ч. банковскими картами. Оплата Заказа данным способом доступна запросом ссылки на оплату у нашего менеджера.
Если у вас возникнут вопросы по оформлению заказа, вы можете обратиться к нам, позвонив по телефону +7 495 137-07-02 или связавшись по электронной почте sale@boschrexroth-russia.ru. Мы гарантируем оперативный ответ на ваш запрос и предоставление наилучших условий от официального поставщика Bosch Rexroth.
Мы предоставляем официальную гарантию на всю поставляемую продукцию Bosch Rexroth.
Гарантийный сервис включает в себя:
- Приемку продукции в сервисный центр для выполнения диагностики дефекта.
- Ремонт продукции.
- Доставку продукции до объекта заказчика.
- Телефон: +7 495 137-07-02
- E-mail: support@boschrexroth-russia.ru
Для расчета коммерческого предложения или получения счета на поставку оборудования и программного обеспечения Bosch Rexroth оставьте заявку в форме ниже или свяжитесь с отделом продаж по телефону +7 495 137-07-02 или электронной почте sale@boschrexroth-russia.ru. Мы гарантируем оперативный ответ на ваш запрос и предоставление наилучших условий от официального поставщика Bosch Rexroth.
Специалист по решениям Bosch Rexroth:
- Окажет профессиональную консультацию.
- Сообщит вашу цену на продукцию.
- Сообщит информацию об актуальных акциях и скидках.
- Подскажет ближайшее к вам отделение с наличием нужной продукции.
- Согласует с вами возможную дату и время доставки.
Нет отзывов об этом товаре.