High-response directional valves, direct operated, with electrical position feedback and integrated electronics (OBE) 4WRPEH 6
Доступно к заказу
Цена по запросу
И выбери подходящего.
Description
- Size 6
- Component series 3X
- Maximum operating pressure 350 bar
- Nominal flow 4 … 40 l/min
- Digital interface IO-Link for I4.0
Features
- Reliable - proven and robust design
- Safe - fail-safe position of the control spool in switched-off condition
- Energy-efficient - no pilot oil demand
- High quality - control spool and sleeve in servo quality
- Flexible - suitable for position, velocity and pressure control
- Precise - high response sensitivity and little hysteresis
- IO-Link interface, optional
Product description
Valves type 4WRPEH are direct operated directional control valve with electrical position feedback and integrated electronics (OBE).
Set-up
The 4WRPEH high-response valve mainly consists of:
- Valve housing with control spool and sleeve in servo quality (1)
- Control solenoid with position transducer (2) (optional with electronics protection membrane (5))
- On-board electronics (OBE) (3) with analog or IO-Link interface (4) (optionally with damping plate (6))
Function
The integrated electronics (OBE) compares the specified command value to the position actual value. In case of control deviations, the stroke solenoid will be activated. Due to the changed solenoid force, the control spool is adjusted against the spring. Stroke/control spool crosssection is controlled proportionally to the command value. In case of a command value presetting of 0, the electronics adjusts the control spool against the spring to central position. In deactivated condition, the spring is untensioned to a maximum and the valve is in fail-safe position.
Control solenoid shut-off
In case of the following faults, the control solenoids are de-energized by the integrated electronics (OBE) and the control spool is set to fail-safe position:
- Falling below the minimum supply voltage
- Only at interface "F1":
- Falling below the minimum current command value of 2 mA (includes cable break of the command value line (current loop))
- Only at interface "L1":
- Enable inactive, communication interruption (watchdog)
- In case of internal IO-Link error
- Only at interface "C6":
- Additionally release inactive
Damping plate "D"
The damping plate reduces the acceleration amplitudes on the on-board electronics (frequencies >300 Hz).
Notice:
Use of the damping plate is not recommended for applications with mainly low-frequency excitation <300 Hz.
Electronics protection membrane "-967"
To prevent condensate formation in the housing of the integrated electronics (OBE), an electronics protection membrane (5) can be used.
Recommended for use outside industry-standard conditions with high ambient air humidity and significant cyclic temperature changes (e.g. outdoors).
Type code
01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | |||
4 | WRP | E | H | 6 | B | ‒ | 3X | / | / | 24 | * |
01 | 4 main ports | 4 | ||
02 | High-response directional valve, direct operated | WRP | ||
03 | With integrated electronics (OBE) | E | ||
04 | Control spool/sleeve | H | ||
05 | Size 6 | 6 | ||
06 | Symbols; for the possible version, see "Symbols/Circuit diagrams" | C3, C5, C4, C1, C | ||
07 | Installation side of the inductive position transducer | B | ||
Rated flow (Δp = 35 bar/control edge) | ||||
08 | Flow characteristic | |||
"L" | "P" | |||
4 l/min | ✔ | ✔ (inflection at 20 %) | 04 | |
12 l/min | ✔ | – | 12 | |
15 l/min | – | ✔ (inflection at 60 %) | 15 | |
24 l/min | ✔ | – | 24 | |
25 l/min | – | ✔ (inflection at 60 %) | 25 | |
40 l/min | ✔ | ✔ (inflection at 40 %) | 40 | |
Flow characteristic | ||||
09 | Linear | L | ||
Inflected characteristic curve, linear | P | |||
10 | Component series 30 … 39 (30 … 39: unchanged installation and connection dimensions) | 3X | ||
Seal material (observe compatibility of seals with hydraulic fluid used, see "Technical data") | ||||
11 | NBR seals | M | ||
FKM seals | V | |||
12 | Without damping plate | no code | ||
With damping plate | D | |||
13 | Supply voltage of the integrated electronics (OBE) 24 VDC | 24 | ||
Interfaces of the control electronics | ||||
14 | Command value input ±10 V | A1 | ||
Command value input 4 ... 20 mA | F1 | |||
IO-Link interface | L1 | |||
Command value ±10 mA, actual value 4 ... 20 mA, release (connector 6+PE) | C6 | |||
15 | Without electronics protection membrane | no code | ||
With electronics protection membrane | -967 | |||
16 | Further details in the plain text | * |
Technical data
(For applications outside these values, please consult us!)
general
Type | 4WRPEH | ||
Size | 6 | ||
Component series | 3X | ||
Design | Directional spool valve, direct operated, with steel sleeve | ||
Type of actuation | Proportional solenoid with position control, OBE | ||
Type of connection | Plate connection, porting pattern according to ISO 4401 | ||
Installation position | Any | ||
Weight | kg | 2.9 | |
Ambient temperature range | °C | -20 … +60 | |
Transport temperature range | °C | -30 … +80 | |
Maximum storage time 1) | yrs | 1 | |
Sine test according to DIN EN 60068-2-6 | Without damping plate | 10 ... 2000 Hz / maximum 10 g / 10 cycles / 3 axes | |
With damping plate 2) | 10 ... 2000 Hz / maximum 10 g / 10 cycles / 3 axes | ||
Noise test according to DIN EN 60068-2-64 | Without damping plate | 20 ... 2000 Hz / 10 gRMS / 30 g peak / 30 min / 3 axes | |
With damping plate 2) | 20 ... 2000 Hz / 10 gRMS / 30 gpeak/24 h/3 axes | ||
Transport shock according to DIN EN 60068-2-27 | Without damping plate | 15 g / 11 ms / 3 shocks / 3 axes | |
With damping plate 2) | 15 g / 11 ms / 3 shocks / 3 axes | ||
Shock test according to DIN EN 60068-2-27 2) | With damping plate | 35 g / 6 ms / 1000 shocks / 3 axes | |
Maximum relative humidity 3) | % | 95 | |
Maximum solenoid surface temperature | °C | 150 | |
MTTFD values according to EN ISO 13849 4) | Years | 150 | |
Conformity | CE according to EMC directive 2014/30/EU tested according EN 61000-6-2 and EN 61000-6-3 RoHS directive 2015/65/EU REACH ordinance (EC) no. 1907/2006 |
1) | If the storage conditions are observed; refer to the operating instructions 07600-B |
2) | Not recommended for applications with mainly low-frequency excitation < 300 Hz |
3) | No condensation |
4) | For further details, see data sheet 08012 |
hydraulic
Type | 4WRPEH | ||
Size | 6 | ||
Maximum operating pressure | Port P | bar | 350 |
Anschluss A | bar | 350 | |
Port B | bar | 350 | |
Port T | bar | 250 | |
Hydraulic fluid | see table "Hydraulic fluid" | ||
Hydraulic fluid temperature range 1) | °C | -20 … +70 | |
Viscosity range | Maximum admissible | mm²/s | 10 … 800 |
Recommended | mm²/s | 20 … 100 | |
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 2) | Class 18/16/13 | ||
Hysteresis | % | < 0.1 | |
Response sensitivity | % | < 0.05 | |
Range of inversion | % | < 0.05 | |
Manufacturing tolerance | % | < 10 | |
Temperature drift 3) | Zero shift < 0.25 %/10 K | ||
Pressure drift | Zero shift < 0.15 %/100 bar |
1) | Flown-through |
2) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. |
3) | Temperature range 20 °C ... 80 °C |
hydraulic
Nominal flow 1) | l/min | 4 | 12 | 15 | 24, 25 | 40 | |
Limitation of use 2) | Symbols C, C3, C5 | bar | 350 | 160 | |||
Symbols C1, C4 | bar | 350 | 280 | 250 | 100 | ||
Leakage flow (at 100 bar) (1:1) | Linear characteristic curve “L” | l/min | < 0.18 | < 0.3 | - | < 0.5 | < 0.9 |
Inflected characteristic curve "P" | l/min | < 0.15 | - | < 0.18 | < 0.3 | < 0.45 |
1) | With Δp = 35 bar/control edge; flow for deviating Δp see formula. |
2) | (∆p) with regard to the transition to failsafe (values apply to summated edge) |
Hydraulic fluid | Classification | Suitable sealing materials | Standards | data sheet | |
Mineral oils | HL, HLP, HLPD, HVLP, HVLPD | NBR, FKM | DIN 51524 | 90220 | |
Bio-degradable | Insoluble in water | HETG | NBR, FKM | ISO 15380 | 90221 |
HEES | FKM | ||||
Soluble in water | HEPG | FKM | ISO 15380 | ||
Flame-resistant | Water-free | HFDU (glycol base) | FKM | ISO 12922 | 90222 |
HFDU (ester base) | FKM | ||||
HFDR | FKM | ||||
Containing water | HFC (Fuchs: Hydrotherm 46M, Renosafe 500; | NBR | ISO 12922 | 90223 | |
Important information on hydraulic fluids:
|
electrical, integrated electronics (OBE) – Interface "A1" and "F1"
Type | 4WRPEH | ||
Size | 6 | ||
Power supply | Nominal voltage | VDC | 24 |
Terminal A | VDC | min. 19 / max. 36 | |
Terminal B | VDC | 0 | |
Relative duty cycle 1) | % | 100 | |
Fuse protection, external | 2.5 AT (time-lag) | ||
Input, version "A1" | Differential amplifier, Ri = 100 kΩ | ||
Terminal D (UE) | VDC | 0 … ±10 | |
Terminal E | VDC | 0 | |
Input, version "F1" | Load, Rsh = 200 Ω | ||
Terminal D (ID-E) | mA | 4 … 20 | |
Terminal E (ID-E) | Current loop ID-E return | ||
Maximum voltage for the differential inputs compared to 0 V | D → B; E → B (max. 18 V) | ||
Test signal, version "A1" | LVDT | ||
Terminal F (UTest) | VDC | 0 … ±10 | |
Terminal C | Reference 0 V | ||
Test signal, version "F1" | LVDT signal 4 … 20 mA on external load 200 … 500 Ω maximum | ||
Terminal F (IF-C) | mA | 4 … 20 | |
Terminal C (IF-C) | Current loop IF-C return | ||
Maximum admissible residual ripple | Vpp | 2.5 | |
Maximum power consumption | VA | 40 | |
Functional earth and screening | see pin assignment under "Electrical connection" (CE-compliant installation) | ||
Adjustment | Calibrated in the plant | ||
Protection class according to EN 60529 | IP65 with mounted and locked plug-in connectors |
1) | Continuous operation |
electrical, integrated electronics (OBE) – Interface "L1"
Power supply | Valve amplifiers | VDC | 24 |
Pin 2 | VDC | min. 18 / max. 30 | |
Pin 5 | VDC | 0 | |
IO-Link interface | VDC VDC | 24 | |
Pin 1 | VDC | min. 18 / max. 30 | |
Pin 3 | VDC | 0 | |
Relative duty cycle 1) | % | 100 | |
Protection class according to EN 60529 | IP65 with mounted and locked plug-in connectors | ||
Maximum current consumption | Valve amplifiers | A | 2 |
IO-Link interface | mA | 50 | |
Maximum admissible residual ripple | Vpp | 1.3 | |
Minimal process cycle time | ms | 0.6 | |
Bit rate COM3 | kBit/s | 230.4 | |
Required master port class | Class B | ||
Resolution | A/D transformer | 12 (110% valve opening) | |
D/A transformer | 12 (110% valve opening) | ||
Adjustment | Calibrated in the plant | ||
Directive | IO-Link Interface and System Specification Version 1.1.2 |
1) | Continuous operation |
electrical, integrated electronics (OBE) – Interface "C6"
Power supply | VDC | 24 | |
Terminal A | VDC | min. 19 / max. 36 | |
Terminal B | VDC | 0 | |
Relative duty cycle 1) | % | 100 | |
Fuse protection, external | 2.5 time-lag | ||
Inlet | Load, Rsh = 200 Ω | ||
Terminal D (ID-E) | mA | 0 … 10 | |
Terminal E (ID-E) | Current loop ID-E return | ||
Test signal | LVDT signal 4 … 20 mA on external load 200 … 500 Ω maximum | ||
Terminal F (IF-C) | mA | 4 … 20 | |
Terminal B (IF-C) | Current loop IF-C return | ||
Maximum power consumption | VA | 40 | |
Functional earth and screening | see pin assignment under "Electrical connection" (CE-compliant installation) | ||
Adjustment | Calibrated in the plant, see "characteristic curves" | ||
Protection class according to EN 60529 | IP65 with mounted and locked plug-in connectors |
1) | Continuous operation |
Diagrams/characteristic curves
Pressure-signal characteristic curve
Pressure-signal characteristic curve
Transition function with stepped electric input signals
Frequency response
Flow / load function with maximum valve opening
Flow characteristic "L"
(measured with HLP46, ϑOil = 40 ±5 °C; Δp = 35 bar/control edge)
Flow/signal function
Symbol C, C3 and C4 – Version "04"
Flow/signal function
Symbol C, C3 and C4 – Version "12"
Flow/signal function
Symbol C, C3 and C4 – Version "24"
Flow/signal function
Symbol C, C3 and C4 – Version "40"
Flow/signal function
Symbol C1 and C5 – Version "04"
Flow/signal function
Symbol C1 and C5 – Version "12"
Flow/signal function
Symbol C1 and C5 – Version "24"
Flow/signal function
Symbol C1 and C5 – Version "40"
Flow characteristic "P"
(measured with HLP46, ϑOil = 40 ±5 °C; Δp = 35 bar/control edge)
Flow/signal function
Symbol C, C3 and C4 – Version "04"
Flow/signal function
Symbol C, C3 and C4 – Version "15"
Flow/signal function
Symbol C, C3 and C4 – Version "25"
Flow/signal function
Symbol C, C3 and C4 – Version "40"
Flow/signal function
Symbol C1 and C5 – Version "40"
Symbols/Circuit diagrams
Symbols
Notice:
Representation according to ISO 1219-1.
Hydraulic interim positions are shown by dashes.
With control symbol C1 and C5, the following applies: | |
P → A: qv nom | B → T: qvnom/2 |
P → B: qvnom/2 | A → T: qv nom |
qV nom 2:1 in connection with flow characteristics "P" for rated flow 40 l/min only (version "40") |
Flow characteristic
Symbol | Linear characteristic curve (version "L") | Inflected characteristic curve (version "P") | ||
Inflection 60 % (qV nom = 15, 25 l/min) | Inflection 40 % | Inflection 20 % | ||
C3, C5 C4, C1 | ||||
C |
Fail-safe position:
Flow/leakage flow
Electrical connection
load errorDimensions
load errorDownloads
Мы предлагаем следующие способы доставки товара:
Самовывоз из пункта выдачи
Самостоятельное получение заказа в пункте выдачи. Дата и время получения заранее согласуется с менеджером магазина.
Отгрузка товара юридическим лицам осуществляется только при наличии печати или правильно оформленной и заполненной доверенности, наличии паспорта получателя.
Курьерская доставка по Москве
Доставка по адресу покупателя или до пункта приема транспортной компании в г. Москве. Дата и время доставки заранее согласуется с менеджером магазина.
Доставка транспортной компанией по России
Доставка транспортной компанией по России до пункта выдачи транспортной компании или до конечного адреса покупателя.
Мы предлагаем следующие способы оплаты товара:
Оплата наличными
Оплата за наличный расчет для физических и юридических лиц. После внесения денежных средств Покупатель подписывает товаросопроводительные документы и получает кассовый чек.
Безналичная оплата
Мы работаем с физическими и юридическими лицами за безналичный расчёт со 100% предоплатой с оформлением всех предусмотренных законодательством документов. Счёт на оплату направляется Покупателю на электронную почту после запроса счета через форму на сайте либо по электронной почте. Цена на заказанный товар действительна в течение 2 дней с момента оформления Заказа.
Электронные способы
Оплата Заказа электронными способами, в т.ч. банковскими картами. Оплата Заказа данным способом доступна запросом ссылки на оплату у нашего менеджера.
Если у вас возникнут вопросы по оформлению заказа, вы можете обратиться к нам, позвонив по телефону +7 495 137-07-02 или связавшись по электронной почте sale@boschrexroth-russia.ru. Мы гарантируем оперативный ответ на ваш запрос и предоставление наилучших условий от официального поставщика Bosch Rexroth.
Мы предоставляем официальную гарантию на всю поставляемую продукцию Bosch Rexroth.
Гарантийный сервис включает в себя:
- Приемку продукции в сервисный центр для выполнения диагностики дефекта.
- Ремонт продукции.
- Доставку продукции до объекта заказчика.
- Телефон: +7 495 137-07-02
- E-mail: support@boschrexroth-russia.ru
Для расчета коммерческого предложения или получения счета на поставку оборудования и программного обеспечения Bosch Rexroth оставьте заявку в форме ниже или свяжитесь с отделом продаж по телефону +7 495 137-07-02 или электронной почте sale@boschrexroth-russia.ru. Мы гарантируем оперативный ответ на ваш запрос и предоставление наилучших условий от официального поставщика Bosch Rexroth.
Специалист по решениям Bosch Rexroth:
- Окажет профессиональную консультацию.
- Сообщит вашу цену на продукцию.
- Сообщит информацию об актуальных акциях и скидках.
- Подскажет ближайшее к вам отделение с наличием нужной продукции.
- Согласует с вами возможную дату и время доставки.
Нет отзывов об этом товаре.