Артикул: RX7382
Directional spool valves, direct operated, with solenoid actuation WE 6...H (7X)
Доступно к заказу
Цена по запросу
И выбери подходящего.
Description
- Size 6
- Component series 7X
- Maximum operating pressure 315 bar
- Maximum flow 60 l/min
Features
- 4/3-, 4/2- or 3/2-way version
- Standard version
- Porting pattern according to DIN 24340, form A
- Wet-pin DC solenoids
- Solenoid coil can be rotated
- The coil can be changed without having to open the pressure-tight chamber
- Electrical connection as individual connection
- Concealed manual override
Product description
Directional valves of type WE are solenoid-actuated directional spool valves. They control the start, stop and direction of a flow.
The directional valves basically consist of the housing (1), one or two solenoids (2), the control spool (3), and one or two return springs (4). In the de-energized condition, control spool (3) is held in the central position or in the initial position by the return springs (4). The control spool (3) is actuated by wet-pin solenoids (2).
To ensure proper functioning, make sure that the pressure chamber of the solenoid is filled with oil!
The force of the solenoid (2) acts via the plunger (5) on the control spool (3) and pushes the latter from its rest position to the required end position. In this way, the required direction of flow according to the symbol is released. After de-excitation of the solenoid (2), the return spring (4) pushes the control spool (3) back to its rest position.
The manual override (6) allows control spool (3) to be moved without solenoid energization.
Type 4WE 6 E7X/H…
Type code
01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | ||
WE | 6 | 7X | / | H | N9 | / | * |
01 | 3 main ports | 3 |
4 main ports | 4 | |
02 | Directional valve | WE |
03 | Size 6 | 6 |
04 | Symbols e. g. D, E etc.; possible design see Symbols | |
05 | Component series 70 … 79 (70 … 79: unchanged installation and connection dimensions) | 7X |
06 | With spring return | no code |
Without spring return with detent | OF1) | |
07 | Standard solenoid wet (wet-pin) | H |
08 | Direct voltage 12 V | G12 |
Direct voltage 24 V | G24 | |
09 | With concealed manual override | N9 |
Electrical connection | ||
10 | Individual connection | |
Without mating connector, with connector DIN EN 175301-803 | K42) | |
Without mating connector, with connector AMP Junior-Timer | C4Z 2) | |
Seal material | ||
11 | NBR seals | no code |
Observe compatibility of seals with hydraulic fluid used. (Other seals upon request) | ||
12 | Further details in the plain text | * |
1) Only symbol D | |
2) Mating connectors, separate order, see data sheet 08006. |
Preferred types and standard units arecontained in the EPS (standard price list).
Technical data
general
Size | 6 | ||
Weight (approx.) | Valve with one solenoid | kg | 1.25 |
Valve with two solenoids | kg | 1.6 | |
Installation position | any | ||
Ambient temperature range | °C | -30 … +50 |
hydraulic
Size | 6 | ||
Maximum operating pressure | Port P | bar | 315 |
Port A | bar | 315 | |
Port B | bar | 315 | |
Port T 1) | bar | 160 | |
Maximum flow | l/min | 60 | |
Hydraulic fluid | see table | ||
Hydraulic fluid temperature range | °C | -30 … +80 | |
Viscosity range | mm²/s | 2.8 … 500 | |
Maximum admissible degree of contamination of the hydraulic fluid 2) | Class 20/18/15 according to ISO 4406 (c) |
1) | With symbols A and B, port T must be used as leakage oil connection if the operating pressure exceeds the admissible tank pressure. |
2) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. |
Hydraulic fluid | Classification | Suitable sealing materials | Standards | |
Mineral oils | HL, HLP, HLPD, HVLP, HVLPD | NBR, FKM | DIN 51524 | |
Bio-degradable | Insoluble in water | HETG | NBR, FKM | VDMA 24568 |
HEES | FKM | |||
Soluble in water | HEPG | FKM | VDMA 24568 | |
Containing water | Water-free | HFDU, HFDR | FKM | ISO 12922 |
Containing water | HFC (Fuchs Hydrotherm 46M, Petrofer Ultra Safe 620 ) | NBR, HNBR | ISO 12922 | |
Important information on hydraulic fluids! For further information and data on the use of other hydraulic fluids, please refer to data sheet 90220 or contact us! There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.)! The flash point of the hydraulic fluid used must be 40 K higher than the maximum solenoid surface temperature. Flame-resistant – containing water: Maximum pressure differential per control edge 50 bar. Pressure pre-loading at the tank port >20% of the pressure differential; otherwise, increased cavitation Life cycle compared to operation with mineral oil HL, HLP 50 to 100 % Bio-degradable: When using bio-degradable hydraulic fluids that are zinc-solving, zinc may accumulate in the fluid (700 mg zinc per pole tube) |
Notices!
- Only actuate the manual override using a rounded tool (Ø3+1 mm) or special tool (separate order, material no. R900024943)!
- Actuation of the manual override only up to a tank pressure 50 bar.
- When the manual override is blocked, the actuation of the solenoid must be prevented!
- The simultaneous actuation of the solenoids must be prevented!
In the electrical connection, the protective earthing conductor (PE, grounded) is to be connected in accordance with the stipulations.
electrical
Voltage type | Direct voltage | ||
Available voltages | V | 12 / 24 | |
Voltage tolerance (nominal voltage) | % | ± 10 | |
Power consumption | W | 26 | |
Duty cycle | % | 100 | |
Maximum coil temperature 1) | °C | 150 | |
Switching time according to ISO 6403 | ON | ms | 20 … 45 |
OFF | ms | 10 … 25 | |
Maximum switching frequency | 1/h | 15000 | |
Protection class according to EN 60529 | IP65 (If a suitable and a correctly mounted mating connector are used.) | ||
Insulation class VDE 0580 | F |
1) | Due to the high surface temperatures of the solenoid coils >50 °C, the standards ISO 13732-1 and ISO 4413 must be adhered and the coils must be equipped with contact protection, if required. |
(For applications outside these values, please consult us!)
Diagrams/characteristic curves
(measured with HLP46, ϑOil = 40 ±5 °C)
Δp-qV characteristic curves
7 | Symbol "H" in central position P – T |
8 | Symbol "G" in central position P – T |
Symbol | Direction of flow | |||
P-A | P-B | A-T | B-T | |
A, B | 3 | 3 | – | – |
C | 1 | 1 | 3 | 1 |
D, Y | 4 | 4 | 3 | 3 |
E | 3 | 3 | 1 | 1 |
J | 1 | 1 | 2 | 1 |
G | 6 | 6 | 7 | 7 |
H | 2 | 5 | 2 | 2 |
Switching power limits (measured with HLP46, ϑOil = 40 ±5 °C)
Notice!
The specified switching power limits are valid for use with two directions of flow (e. g. from P to A and simultaneous return flow from B to T).
Due to the flow forces acting within the valves, the admissible switching power limits may be considerably lower with only one direction of flow (e. g. from P to A while port B is blocked)!
In such use cases, please consult us!
The switching power limit was established while the solenoids were at operating temperature, at 10 % undervoltage and without tank preloading.
DC solenoid | |
Characteristic curve | Symbol |
1 | A, B |
2 | C, Y |
3 | E |
4 | J |
5 | D |
6 | G, H |
7 | D/OF |
Symbols/Circuit diagrams
1) | Only symbol D |
2)Example: Symbol E with switching position "a" Ordering code ..EA.. |
Dimensions
Version "K4"
Dimensions in mm
Required surface quality of the valve contact surface |
1.1 | Solenoid “a” |
1.2 | Solenoid “b” |
2 | Mating connector without circuitry (separate order) |
3 | Mating connector with circuitry (separate order) |
4 | Name plate |
5 | Space required to remove the mating connector |
6 | Space required to remove the coil |
7 | Mounting nut, MA = 4+1 Nm |
8 | Plug screw for valve with one solenoid |
9 | Identical seal rings for ports A, B, P, T |
10 | Porting pattern according to DIN 24340 form A |
Version "C4Z"
Dimensions in mm
Required surface quality of the valve contact surface |
1.1 | Solenoid “a” |
1.2 | Solenoid “b” |
4 | Name plate |
5 | Space required to remove the mating connector |
6 | Space required to remove the coil |
7 | Mounting nut, MA = 4+1 Nm |
8 | Plug screw for valve with one solenoid |
9 | Identical seal rings for ports A, B, P, T |
10 | Porting pattern according to DIN 24340 form A |
11 | Mating connector "Junior Timer", straight (separate order, see data sheet 08006) |
12 | Mating connector "Junior Timer", angled (separate order, see data sheet 08006) |
Subplates according to data sheet 45052 (separate order)
G 341/01 (G1/4)
G 342/01 (G3/8)
G 502/01 (G1/2)
Valve mounting screws (separate order)
- 4 hexagon socket head cap screws ISO 4762 - M5 x 50 - 10.9-flZn-240h-L
(friction coefficient μtotal = 0.09 to 0.14);
tightening torque MA = 7 Nm ± 10 %,
material no. R913000064
or
- 4 hexagon socket head cap screws ISO 4762 - M5 x 50 - 10.9
with friction coefficient μtotal = 0.12 to 0.17 a
tightening torque MA = 8.1 Nm ± 10 % results
(not included in the Rexroth delivery range)
Accessories
Mating connectors for valves with connector “K4”, without circuitry, standard
3P Z4
Mating connectors for valves with connector “K4”, without circuitry, standard
3P Z4
- For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector”
- Mating connectors for valves with one or two solenoids (individual connection)
Mating connectors for valves with connector “K4”, with indicator light
3P Z5L
Mating connectors for valves with connector “K4”, with indicator light
3P Z5L
- For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector”
- Mating connectors for valves with one or two solenoids (individual connection)
Mating connectors for valves with connector “K4”, with indicator light and Zener diode suppression circuit
3P Z5L1
Mating connectors for valves with connector “K4”, with indicator light and Zener diode suppression circuit
3P Z5L1
- For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector”
- Mating connectors for valves with one or two solenoids (individual connection)
Mating connectors for valves with connector “K4”, with rectifier
3P RZ5
Mating connectors for valves with connector “K4”, with rectifier
3P RZ5
- For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector”
- Mating connectors for valves with one or two solenoids (individual connection)
Downloads
Directional spool valves, direct operated, with solenoid actuation Data Sheet | RE23164 | 2013-01-01 | English | PDF | 576k Product Groups: Direct operated Type WE |
Мы предлагаем следующие способы доставки товара:
Самовывоз из пункта выдачи
Самостоятельное получение заказа в пункте выдачи. Дата и время получения заранее согласуется с менеджером магазина.
Отгрузка товара юридическим лицам осуществляется только при наличии печати или правильно оформленной и заполненной доверенности, наличии паспорта получателя.
Курьерская доставка по Москве
Доставка по адресу покупателя или до пункта приема транспортной компании в г. Москве. Дата и время доставки заранее согласуется с менеджером магазина.
Доставка транспортной компанией по России
Доставка транспортной компанией по России до пункта выдачи транспортной компании или до конечного адреса покупателя.
Мы предлагаем следующие способы оплаты товара:
Оплата наличными
Оплата за наличный расчет для физических и юридических лиц. После внесения денежных средств Покупатель подписывает товаросопроводительные документы и получает кассовый чек.
Безналичная оплата
Мы работаем с физическими и юридическими лицами за безналичный расчёт со 100% предоплатой с оформлением всех предусмотренных законодательством документов. Счёт на оплату направляется Покупателю на электронную почту после запроса счета через форму на сайте либо по электронной почте. Цена на заказанный товар действительна в течение 2 дней с момента оформления Заказа.
Электронные способы
Оплата Заказа электронными способами, в т.ч. банковскими картами. Оплата Заказа данным способом доступна запросом ссылки на оплату у нашего менеджера.
Если у вас возникнут вопросы по оформлению заказа, вы можете обратиться к нам, позвонив по телефону +7 495 137-07-02 или связавшись по электронной почте sale@boschrexroth-russia.ru. Мы гарантируем оперативный ответ на ваш запрос и предоставление наилучших условий от официального поставщика Bosch Rexroth.
Мы предоставляем официальную гарантию на всю поставляемую продукцию Bosch Rexroth.
Гарантийный сервис включает в себя:
- Приемку продукции в сервисный центр для выполнения диагностики дефекта.
- Ремонт продукции.
- Доставку продукции до объекта заказчика.
- Телефон: +7 495 137-07-02
- E-mail: support@boschrexroth-russia.ru
Для расчета коммерческого предложения или получения счета на поставку оборудования и программного обеспечения Bosch Rexroth оставьте заявку в форме ниже или свяжитесь с отделом продаж по телефону +7 495 137-07-02 или электронной почте sale@boschrexroth-russia.ru. Мы гарантируем оперативный ответ на ваш запрос и предоставление наилучших условий от официального поставщика Bosch Rexroth.
Специалист по решениям Bosch Rexroth:
- Окажет профессиональную консультацию.
- Сообщит вашу цену на продукцию.
- Сообщит информацию об актуальных акциях и скидках.
- Подскажет ближайшее к вам отделение с наличием нужной продукции.
- Согласует с вами возможную дату и время доставки.
Нет отзывов об этом товаре.