Доступно к заказу
Цена по запросу
И выбери подходящего.
Description
- Component series 2X
- Analog, Euro-card format
- For valves: 4WRPH 10…L-2X
Features
- Double card for simultaneous operation of two high-response valves
- Controlled output stage
- Enable input
- Short-circuit-proof outputs
- Adjustable zero point
- Cable break detection for actual value cable
Product description
Applications
2-axis control in presses, forming machines and machine tools.
Plug-in connections
2 x DIN 41612, 32-pole, for low-power signals (command value, enable, etc.).
Screw-plug-in connection to the valve and for supply voltage on handle side (ST 4, 5 and ST 9, 10) included in the scope of delivery.
Test points
IC base on handle side for control measurements and signal inputs.
Displays
For cable break, enable and undervoltage.
Direct voltage controller (DC/DC converter)
For the supply of command value encoders, position transducers and internal supply together for both channels.
Type code
| 01 | Valve amplifiers for control valves, analog, Euro-card format | VT-KRRA2 |
| 02 | For valves: 4WRPH 10…L-2X | 537 |
| 03 | Component series 20 ... 29 (20 ... 29: unchanged technical data and pin assignment) | 2X |
| 04 | Version: standard | V0 |
| 05 | 2-channel variant | 2CH |
| 01 | 02 | 03 | 04 | 05 | ||||
| VT-KRRA2 | ‒ | 537 | ‒ | 2X | / | V0 | / | 2CH |
Technical data
General
| Component series | 2X | ||
| Material number | Data sheet | 1819929052 | |
| Type of electronics | Analog | ||
| Design | Double euro-card | ||
Voltage supply
| Operating voltage | Nominal | U | V | 24 |
| Lower limit value | UB(t)min | V | 21 | |
| Upper limit value | UB(t)max | V | 40 | |
| Ripple 1) | % | < 10 | ||
| Power consumption | P | VA | 55 | |
| Current consumption | max. | Imax | A | 2.7 |
| 1) | In case of ripple > 10 %, an upstream smoothing capacitor is required (recommendation: capacitor module VT 11110) |
Analog inputs
| Command value source | External electronic control system, internal reference voltage | ||||
| Command value | Voltage | Differential input | U | V | 0 ... ±10 |
| Input resistance | R | kΩ | ≥ 100 | ||
| position value 1) | Voltage | U | V | 0 … ±10 | |
| 1) | RL > 10 kΩ |
Digital inputs
| Enable 1) | On (active) | U | V | 8.5 ... 40 |
| 1) | RE = 100 kΩ |
Digital outputs
| Cable break error message | No error 1) | UB | V | 24 |
| Error | UB | V | 0 |
| 1) | Imax = 100 mA |
Solenoid outputs
| Solenoid current | max. | Imax | A | 3.7 |
Position transducer
| Position transducer supply 1) | U | V | ±15 |
| 1) | Imax = 200 mA, short-circuit-proof |
Displays
| LED display | Green 1 | Enable | |
| Yellow 1 | Cable break actual value | ||
| Red | UB too low |
Other information
| Reference voltage | Potentiometer supply | U | V | ±10 (Imax = 10 mA) |
| Anschlussart | Connector DIN 41612, design D, as well screw-plug-in connection on handle side | |||
| Ambient temperature range | ϑ | °C | 0 … 70 | |
| Storage temperature range | ϑ | °C | -20 … 70 | |
| Weight | m | kg | 0.54 | |
(For applications outside these values, please consult us!)
Symbols/Circuit diagrams
Dimensions
Dimensions in mm

Dimensions in mm
Project planning information
The amplifier card may only be unplugged and plugged when de-energized.
The distance to aerial lines, radios, and radar systems has to be at least 1 m.
Do not lay solenoid and signal lines near power cables.
For signal lines and solenoid conductors, we recommend using shielded cables.
The cable shield must be connected to the control cabinet extensively and as short as possible.
The valve solenoid must not be connected to free-wheeling diodes or other protection circuits.
The cable lengths and cross-sections specified in the technical data must be complied with.
Mounting
Wiring information
Power zero and control zero c14/c12 must be bridged.
If the distance to the power supply unit is <1 m, directly onto the DIN connector at c2/c4.
With larger distances, lead the control separately to the ground.
Connect the supply voltage to connectors ST 4 and ST 9.
Downloads
| 电气放大器 Data Sheet | RC30049 | 2014-07-11 | Chinese | PDF | 2.6MB Product Groups: Valve amplifiers VT-KRRA2-5...-2X/... | |
| Amplificateurs électriques Data Sheet | RF30049 | 2014-07-11 | French | PDF | 2.1MB Product Groups: Valve amplifiers VT-KRRA2-5...-2X/... | |
| Amplificador eléctricos Data Sheet | RS30049 | 2014-07-11 | Spanish | PDF | 2.1MB Product Groups: Valve amplifiers VT-KRRA2-5...-2X/... | |
| Elektrische Verstärker Data Sheet | RD30049 | 2014-07-11 | German | PDF | 1.8MB Product Groups: Valve amplifiers VT-KRRA2-5...-2X/... | |
| Electric amplifiers Data Sheet | RE30049 | 2014-07-11 | English | PDF | 2.1MB Product Groups: Valve amplifiers VT-KRRA2-5...-2X/... |



Нет отзывов об этом товаре.