Артикул: RX8481
Linear Sets with Super Linear Bushings H, open-type, R1703 LSAHO-H-..-VD
Доступно к заказу
Цена по запросу
И выбери подходящего.
Description
- Precision housing (aluminum)
- Super Linear Bushing H
- Compensate for misalignments of up to 30 ft
- Fully sealed
- Secured with bolt
Features
- Relubricatable
Technical data
General technical data
| Ø d | mm | 20 | 25 | 30 | 40 | 50 | 60 |
| amax | m/s² | 150 | |||||
| vmax | m/s | 5 | |||||
| m | kg | 0.24 | 0.48 | 0.72 | 1.38 | 2.3 | 4.4 |
| FR 1) | N | 4 | 4.5 | 6 | 7.5 | 9 | 10.5 |
| Breakaway force | N | 7.5 | 10.5 | 13.5 | 18 | 22.5 | 27 |
| Shaft radial clearance h6 2) | µm | + 31 - 2 | + 35 - 3 | + 39 - 4 | |||
| Operating conditions | |||||||
| Permissible ambient temperature (min ... max) | -20 °C ... +80 °C | ||||||
| 1) | Frictional drags generated by Linear Bushings with integrated wiper seals on two sides when not under radial load. The frictional drags depend on speed and lubrication. |
| 2) | Clamped (fastened). |
Load capacities and load moments
| Ød | mm | 20 | 25 | 30 | 40 | 50 | 60 |
| C 1) | N | 2520 | 4430 | 6300 | 9680 | 16000 | 23500 |
| C0 1) | N | 1880 | 3360 | 5230 | 7600 | 12200 | 18700 |
| 1) | The load ratings apply for the main direction of loading. |
| The load ratings are based on a total travel of 100, 00 m. When based on 50 000 m, the values in the table need to be multiplied by 1.26. |
Legend
| Symbol | Description | Unit |
| Ød | Shaft diameters | mm |
| amax | Maximum acceleration travel | m/s2 |
| C | Dynamic load capacity | N |
| C0 | Static load capacity | N |
| FR | Friction force | N |
| m | Mass | kg |
| vmax | Maximum permissible speed | m/s |
See "Technical data – Load direction factors" and the diagrams/characteristic curves section for exact values for the 4 main directions of loading.
Refer to the "Load direction factor" diagrams for load in the direction of opening.
Effect of load direction on load rating

| a) | Closed |
| b) | Open |
Main direction of loading

Load direction factors
The load ratings C and C0 apply for the load direction ρ = 0°. For all other load directions, the load ratings must be multiplied by the factors fr (dynamic load rating C) or fρ0 (static load rating C0).
Load direction factor Super H
| Shaft | Load direction factor (dynamic load capacity) | |||||
| Ø d (mm) | ⇩ | ⇒⇐ | ⇑ | ⇩ | ⇒⇐ | ⇑ |
| 20 - 25 | 1 | 0,80 | 0,98 | 1 | 0,80 | 0,67 |
| 30 - 60 | 1 | 0,70 | 0,91 | 1 | 0,70 | 0,62 |
| Load direction factor (static load capacity) | ||||||
| 20 - 25 | 1 | 0,70 | 0,87 | 1 | 0,70 | 0,67 |
| 30 - 60 | 1 | 0,62 | 0,80 | 1 | 0,62 | 0,61 |
| | |||||
Reduced load capacity with short stroke
In case of short stroke, the service life of the shaft is less than that of the super Linear Bushing. The load ratings C specified in the tables must therefore be multiplied by the factor f.s .

| 1) | fs = factor |
| 2) | s = movement path |
Reduced load capacity with high load
The load rating is reduced under high load F. The dynamic load rating must be multiplied by the load factor f.F .

| 1) | fF = load factor |
Definition of dynamic load ratings
Tolerances and guide parallelism in operation for R1703 and R1704 Linear Sets and steel shaft with ready-mounted R1014 shaft support rail

| 1) | See "Tolerances" table for exact values. |
| 2) | P1 = parallelism P1 |
| 3) | L = guide length |
| a) | Single or combined shaft support rails |
Dimensioned drawing for tolerances and guide parallelism during operation for R1703 and R1704 Linear Sets and steel shaft with ready-mounted R1014 shaft support rail

Tolerances and guide parallelism during operation for R1703 and R1704 Linear Sets and steel shaft with ready-mounted R1014 shaft support rail
|
| Tolerance zone of the shaft | Shaft Ød (mm) | ||||||
| 20 | 25 | 30 | 40 | 50 | 60 | |||
| Tolerances (µm) 3) | H01)4) | h6 | +18 | +18 | +18 | +18 | +18 | +18 |
| -39 | -39 | -39 | -42 | -42 | -45 | |||
| h7 | +18 | +18 | +18 | +18 | +18 | +18 | ||
| -47 | -47 | -47 | -51 | -51 | -56 | |||
| Parallelism P1 2)4) | h6 | 30 | 30 | 30 | 32 | 32 | 33 | |
| h7 | 32 | 32 | 32 | 35 | 35 | 35 | ||
| 1) | Measured from center of housing. |
| 2) | With clamped and fastened guide. |
| 3) | The tolerances apply for the set with shaft and shaft support rail. |
| 4) | Single or combined shaft support rails |
Tolerances and guide parallelism in operation for R1703 and R1704 Linear Sets and steel shaft with ready-mounted R1016 shaft support rail

| 1) | See "Tolerances" table for exact values. |
| 2) | Shaft support rail consists of multiple parts of same type. |
| 3) | P1 = parallelism P1 |
| 4) | P2 = parallelism P2 |
| 5) | L = guide length |
| a) | Single shaft support rail |
| b) | Combined shaft support rails |
Dimensioned drawing for tolerances and guide parallelism during operation for R1703 and R1704 Linear Sets and steel shaft with ready-mounted R1016 shaft support rail

Tolerances and guide parallelism during operation for R1703 and R1704 Linear Sets and steel shaft with ready-mounted R1016 shaft support rail
|
| Tolerance zone of the shaft | Shaft Ød (mm) | |||||
| 20 | 25 | 30 | 40 | 50 | |||
| Tolerances (µm) 3) | H01) Multiple shaft support rails | h6 | +28 | +28 | +28 | +28 | +28 |
| -69 | -69 | -69 | -72 | -72 | |||
| h7 | +28 | +28 | +28 | +28 | +28 | ||
| -77 | -77 | -77 | -81 | -81 | |||
| H01) Single shaft support rail | h6 | 57 | 57 | 57 | 60 | 60 | |
| h7 | 65 | 65 | 65 | 67 | 69 | ||
| Parallelism P1 2) Combined shaft support rails | h6 | 30 | 30 | 30 | 32 | 32 | |
| h7 | 32 | 32 | 32 | 35 | 35 | ||
| Parallelism P1 2) Single shaft support rail | h6 | 20 | 20 | 20 | 22 | 22 | |
| h7 | 22 | 22 | 22 | 25 | 25 | ||
| Parallelism P2 2) Combined shaft support rails | h6 | 45 | 45 | 45 | 46 | 46 | |
| h7 | 46 | 46 | 46 | 48 | 48 | ||
| Parallelism P2 2) Combined shaft support rails | h6 | 15 | 15 | 15 | 16 | 16 | |
| h7 | 16 | 16 | 16 | 18 | 18 | ||
| A31) | h6 | +30 | +30 | +30 | +30 | +30 | |
| -37 | -37 | -37 | -38 | -38 | |||
| h7 | +30 | +30 | +30 | +30 | +30 | ||
| -41 | -41 | -41 | -43 | -43 | |||
| 1) | Measured from center of housing. |
| 2) | With clamped and fastened guide. |
| 3) | The tolerances apply for the set with shaft and shaft support rail. |
| 4) | Single or combined shaft support rails |
Diagrams/characteristic curves
Load direction factors

| a) | Closed |
| b) | Open |
Super Linear Bushings can be installed in any location. Choose a location that ensures that the main direction of loading is always ρ = 0°.
Dimensions

| a) | Lubricating hole sealed with plastic cap |

| a) | Lubricating hole sealed with plastic cap |
Dimensions
| Ød | mm | 20 | 25 | 30 | 40 | 50 | 60 |
| D | mm | 32 | 40 | 47 | 62 | 75 | 90 |
| α | ° | 54 | 55 | 60 | 52 | 55 | |
| A | mm | 60 | 78 | 87 | 108 | 132 | 164 |
| E1 | 45 mm ±0.15 | 60 mm ±0.15 | 68 mm ±0.15 | 86 mm ±0.15 | 108 mm ±0.2 | 132 mm ±0.2 | |
| E2 | 32 mm ±0.15 | 40 mm ±0.15 | 45 mm ±0.15 | 58 mm ±0.15 | 50 mm ±0.2 | 65 mm ±0.2 | |
| E3 | mm | 50 | 64 | 72 | 90 | 108 | 132 |
| E4 | mm | 15 | 17 | 20 | 25 | 85 | 108 |
| H | mm | 25 | 30 | 35 | 45 | 50 | 60 |
| Tolerance for H 1) | µm | + 8 - 16 | |||||
| H1 | mm | 42 | 51 | 60 | 77 | 88 | 105 |
| H3 | mm | 10 | 11.5 | 14 | 12.5 | 15 | |
| H4 | mm | 3.5 | 4 | 6 | 5 | ||
| L | mm | 46 | 59 | 69 | 81 | 101 | 126 |
| L3 | mm | 16 | 21 | 26 | 30 | 39 | 50 |
| M 1) | 30 mm ±0.01 | 39 mm ±0.01 | 43.5 mm ±0.01 | 54 mm ±0.01 | 66 mm ±0.01 | 82 mm ±0.01 | |
| N1 | mm | 24 | 29 | 34 | 44 | 49 | 59 |
| N2 | mm | 18 | 22 | 26 | 34 | 42 | |
| S | mm | 6.6 | 8.4 | 10.5 | 13.5 | 17.5 | |
| S1 | M8 | M10 | M12 | M16 | M20 | ||
| S2 | mm | 5 | 6 | 8 | 10 | 12 | |
| SW | mm | 2.5 | 3 | 4 | 5 | 6 | |
| V | mm | 5 | 6.5 | 8 | 10 | 12 | 13 |
| W | mm | 9.5 | 12 | 12.8 | 16.8 | 22.1 | 27 |
| 1) | Clamped (fastened) in relation to Ø d. |
Legend
| Symbol | Description | Unit |
| Ød | Shaft diameters | mm |
| C/C0 | Main direction of loading |
Legend
| Symbol | Description | Unit |
| Ød | Shaft diameters | mm |
| C/C0 | Main direction of loading |
Project planning information
Life expectancy calculation
Mounting
General mounting instructions
Commissioning
load errorMaintenance
load errorCertification
load errorSafety Instructions
load errorDownloads
| Linear Bushings and Shafts Manual | R320103669 | 2005-07-01 | English, French, German, Italian | PDF | 3.6MB Product Groups: Linear Bushings and Shafts | |
| Linear Bushings Catalog | R999000488 | 2015-02-01 | English | PDF | 14.9MB Product Groups: Linear Bushings and Shafts |



Нет отзывов об этом товаре.