Description
- Free movement is possible
Product description
Table part
On table parts with an integrated clamping unit, a standard air connection (1) is located opposite the lube nipples. Connection to an air connection is sufficient.

Clamping unit (LKPS)
The clamping unit is used exclusively for clamping linear axes (static holding)
Owing to the spring energy accumulator, it is closed in the deenergized condition (NC).
The clamping unit is usable as a proven component in connection with a suitable function test and in category 1 controls as per DIN EN ISO 13849-1:2006.
If the user risk assessment determines a Performance Level (see Appendix A, DIN EN ISO 13849-1:2006) requiring a higher category, further technical control measures are necessary for safe holding or for preventing startup from the immobile position.
For further instructions and information, please refer to documentation belonging to this product.
The clamping unit must only be used when the axis is at a standstill.
The clamping unit may not be used as a braking unit!
Use for the emergency braking of a moving weight is not permissible.
Clamping during movement may lead to the destruction of the clamping unit as well as he linear guide!
Technical data
Air pressure: 0 bar

Clamps with spring force
In the event of pressure drop, the clamping profiles are pressed onto the guide rail by a spring energy accumulator.
A quick-release valve for short reaction times is required.
Air pressure: 5.5 - 8 bar

Decompression with air pressure
The clamping profiles are held apart by the compressed air.
- Free movement is possible
Technische Daten
| Size | OBB-055 | OBB-085 | OBB-120 | |
| Holding force 1) | N | 400 | 750 | 1300 |
| Pressure min. (release pressure) | bar | 5.5 | ||
| Max. pressure | bar | 8 | ||
| Spring energy accumulator | ✓ | |||
| Clamping cycles 2) | up to 5 million (B10d-value) | |||
| Braking cycles | not allowed | |||
| Push-in fitting for hose | Ø 4 mm | |||
| Actuation | Pneumatic | |||
| theor. air consumption per cycle at 6 bar | cm³ | 23 | 54 | 74 |
| Air quality | lubricated air as per ISO 8573-1 class 4, filter mesh size 25 μm | |||
| 1) | Static holding of the omega module or frame for axial forces up to each specified value. |
| 2) | The B10d-value specifies the number of switching cycles until 10% of components fail dangerously. |