Затрудняетесь с выбором?
Оставьте ваш телефон, и наш специалист перезвонит вам

Артикул: RX7381

Все товары Bosch Rexroth

Directional spool valves, direct operated, with solenoid actuation WE 6 …E..XN

Доступно к заказу

Цена по запросу

Получи КП от 5 лучших поставщиков
С указанием цены, наличия, сроков поставки и скидок.
И выбери подходящего.

Description

  • Size 6
  • Component series 6X
  • Maximum operating pressure 350 bar
  • Maximum flow 80 l/min
  • Area of application in accordance with the Explosion Protection Directive 2014/34/EU: II 3G; II 3D
  • Area of application according to technical rules EAC TR CU 012/2011: II 3G; II 3D
  • Type of protection of the valve solenoids:
    – Ex ec IIC T3 Gc according to EN 60079-7
    – Ex tc IIIC T140°C Dc according to EN 60079-31

Features

  • 4/3-, 4/2- or 3/2-way version
  • Porting pattern according to ISO 4401-03-02-0-05
  • Wet-pin DC solenoids
  • Solenoid coil is rotatable by 90°
  • Electrical connection as individual connection
  • With concealed manual override

Product description

The directional valves of type WE are solenoid-actuated directional spool valves. They control the start, stop and direction of a flow.

The directional valves basically consist of the housing (1), one or two electronic solenoids (2), the control spool (3), and one or two return springs (4).

In the de-energized condition, the control spool (3) is held in the central position or in the initial position by the return springs (4) (except for version "O"). The control spool (3) is actuated by wet-pin electronic solenoids (2).

For perfect functioning, the hydraulic system must be bled properly.

The force of electronic solenoid (2) acts via the plunger (5) on the control spool (3) and pushes the latter from its rest position to the required end position. This enables the necessary direction of flow from P to A and B to T or P to B and A to T.

When the electronic solenoid (2) is de-excitated, the return spring (4) pushes the control spool (3) back to its rest position.

An optional manual override (6) allows the control spool (3) to be moved without solenoid energization.

Without spring return "O" (only possible with symbols A, C and D)

This version is a directional valve with two spool positions and two electronic solenoids without detent. The valve without spring return at the control spool (3) has no defined basic position in the de-energized condition.

Without spring return with "OF" detent (only possible with symbols A, C and D)

This version is a directional valve with two spool positions and two electronic solenoids with detent. The detents are used to lock the control spool (3) in the relevant spool position. During operation, continuous application of current to the electronic solenoid can thus be omitted which contributes to energy-efficient operation.

Notices:

Pressure peaks in the tank line to two or several valves can result in unintended movements of the control spool in the version with detent. We therefore recommend that separate return lines be provided or a check valve installed in the tank line.

Due to the design principle, internal leakage is inherent to the valves, which may increase over the life cycle.

Type 4WE 6 E6X/...E..XNK4...

Throttle insert "...B"

The use of a throttle insert is required when, due to prevailing operating conditions, flows occur during the switching processes, which exceed the performance limit of the valve.

1)Seal ring

Type code

01

02

03

04

05

06

07

08

09

10

11

12

13

WE

6

6X

/

E

G24

N9

XN

K4

/

01

3 main ports

3

4 main ports

4

02

Directional valve

WE

03

Size 6

6

04

Symbols; for the possible version, see "Symbols/Circuit diagrams"

05

Component series 60 … 69 (60 … 69: unchanged installation and connection dimensions)

6X

06

With spring return

no code

Without spring return

O

Without spring return with detent

OF

07

High-power solenoid, wet-pin, with detachable valve solenoid

E

08

Direct voltage 24 V

G24

09

With concealed manual override

N9

Explosion protection

10

"Not igniting", for details, please refer to the "information on explosion protection"

XN

Electrical connection

11

Solenoid without mating connector, see "Electrical connection"

K4

Throttle insert

12

Without throttle insert

no code

Throttle Ø 0.8 mm

B08

Throttle Ø 1.0 mm

B10

Throttle Ø 1.2 mm

B12

Use if flow > performance limit of the valve

Seal material (observe compatibility of seals with hydraulic fluid used, see "Technical data")

13

NBR seals

no code

FKM seals

V

Technical data

general

Size

6

Installation position

any

Ambient temperature range 1)

°C

-20 … +50

Storage temperature range

°C

+5 … +40

Maximum storage time

yrs

1

Weight

Valve with one solenoid

kg

2.3

Valve with two solenoids

kg

2.85

Surface protection

Galvanized
1)Maximum 40 °C when using the cable sets DS2513.

hydraulic

Size

6

Maximum operating pressure

Port P

bar

350

Port A

bar

350

Port B

bar

350

Port T 1)

bar

210

Maximum flow

l/min

80

Flow cross-section (spool position 0)

Symbol Q

approx. 6 % of nominal cross-section

Symbol W

approx. 3 % of nominal cross-section

Hydraulic fluid

see table "Hydraulic fluid"

Hydraulic fluid temperature range 2)

NBR seals

°C

-20 … +80

FKM seals

°C

-15 … +80

Viscosity range

mm²/s

2.8 … 500

Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 3)

Class 20/18/15
1)With symbols A and B, port T must be used as leakage oil connection if the operating pressure exceeds the admissible tank pressure.
2)Observe the "Special application conditions for safe application"
3)The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Data sheet

Mineral oils

HL, HLP, HLPD

NBR, FKM

DIN 51524

90220

Bio-degradable

Insoluble in water

HETG

FKM

ISO 15380

90221

HEES

FKM

Soluble in water

HEPG

FKM

ISO 15380

Important information on hydraulic fluids:

  • For more information and data on the use of other hydraulicfluids, please refer to the data sheets above or contact us.
  • There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.).
  • Ignition temperature > 190 °C
  • Flame-resistant – containing water:
    • Maximum pressure differential per control edge 50 bar
    • Pressure pre-loading at the tank port > 20 % of the pressure differential, otherwise increased cavitation
    • Life cycle as compared to operation with mineral oil HL, HLP 50 … 100%.

electrical

Voltage type

Direct voltage

Available voltages

V

24

Voltage tolerance (nominal voltage)

%

± 10

Admissible residual ripple

%

< 5

Duty cycle

100% (S1 according to VDE 0580)

Rated current

mA

950

Switching time according to ISO 6403 1)

ON

ms

​25 … ​45

OFF

ms

10 … 25

Maximum switching frequency

1/s

4.2

Maximum switch-off voltage peaks Solenoid 2)

V

500

Nominal power with ambient temperature 20 °C

W

23

Maximum power with 1.1 x nominal voltage and an ambient temperature of 20 °C

W

28.8

Protection class according to EN 60529 3)

IP65
1)The switching times were determined at a hydraulic fluid temperature of 40 °C and a viscosity of 46 mm2/s. Deviating hydraulic fluid temperatures can result in different switching times. Switching times change dependent on operating time and application conditions.
2)Suitable damping by user required
3)If a suitable mating connector and a correctly mounted electric connection are used.

Information on explosion protection – Directive 2014/34/EU

Area of application

II 3GII 3D

Type of protection valve

c (EN 13463-5)

Type of protection valve solenoid according to EN 60079-7 / EN 60079-31

Ex ec IIC T3 GcEx tc IIIC T140°C Dc X

Maximum surface temperature 1)

°C

140

Temperature class

T3

Type examination certificate solenoid

BVS 12 ATEX E 062 X

Requirements on the mating connector

Temperature rating 2)

°C

≥ 100

Area of application according to directive 2014/34/EU

II 3GII 3D
1)Surface temperature > 50 °C, provide contact protection.
2)Transfer temperature at the connector of the valve solenoid 85 °C at ambient temperature 40 °C.

Information on explosion protection – Technical rules EAC TR CU 012/2011

Area of application

II 3GII 3D

Type of protection marking of valve

2Ex nA II T3 Gc XEx tc IIIC T140°C Dc X

Maximum surface temperature 1)

°C

140

Temperature class

T3

Certificate of conformity

No TC RU C-DE.ГБ08.В.02161
1)Surface temperature > 50 °C, provide contact protection.

Special application conditions for safe application

  • Connection lines must be passed in a pull-relieved way.
  • The valve is to be installed in a way that no impact stress > 4 J can become effective.
  • In order to avoid dangers caused by static charge, the base and/or subplate on which the valve is to be fitted must be electrically conductive and included in the equipotential bonding.
  • The valve must not be installed close to charge generating processes.
  • Dust layers with a thickness of > 50 mm are inadmissible.
  • Maximum hydraulic fluid temperature:
    In case of bank assembly, as long as only one solenoid is energized at a time and in case of individual assembly: +80 °C
    In case of bank assembly, if more than one solenoids are energized simultaneously: +65 °C
  • The maximum temperature of the surface of the valve jacket is 110 °C. This has to be considered when selecting the connection cable and/or contact of the connection cable with the surface of the jacket is to be prevented.

Diagrams/characteristic curves

(measured with HLP46, ϑOil = 40 ±5 °C)

Δp-qV characteristic curves

Symbol

Direction of flow

P – A

P – B

A – T

B – T

B – A

P – T

A, B

3

3

C46, C

1

1

3

1

D46, D, Y

5

5

3

3

E

3

3

1

1

F

1

3

1

1

T

10

10

9

9

8

H

2

4

2

2

9

J, Q

1

1

2

1

L

3

3

4

9

M

2

4

3

3

P

3

1

1

1

R

5

5

4

7

V

1

2

1

1

W

1

1

2

2

U

3

3

9

4

G

6

6

9

9

8

Performance limits

(measured with HLP46, ϑOil = 40 ±5 °C)

Notice:

The specified performance limits are valid for operation with two directions of flow (e.g. from P to A and simultaneous return flow from B to T).
Due to the flow forces acting within the valves, the possible performance limit may be considerably lower with only one direction of flow (e.g. from P to A while port B is blocked).
The performance limits were determined when the solenoids were at operating temperature, at 10% undervoltage and without tank preloading.

Symbol

Characteristic curve

A, B

1

J, L, U

2

V

3

D, C, Y

4

Q, W

5

A/0, A/0F

6

F, P

7

T

8

G

9

H

10

D/0F, C/0F

11

M, D/0, C/0

12

E1, R, E

13

Symbols/Circuit diagrams

1)Example:
Symbol E with spool position "a" → ordering code ..EA..
2)Symbol E1-: P – A/B pre-opening, Caution in conjunction with differential cylinders due to pressure intensification.

Notice:

Representation according to ISO 1219-1.

Hydraulic interim positions are shown by dashes.

Electrical connection

The type-examination tested valve solenoid of the valve is equipped with an electrical connection according to the following table. The electrical connection of the solenoid is polarity-independent.

Electrical connections and coil connection combinations

Ordering code connector

Top view

Circuit diagram

Pin

Connections, assignment

3-pole connector (2+PE) according to DIN EN 175301-803

K4

1

Solenoid coil, polarity-independent

2

Earthing

1)M3, max. tightening torque MA max = 1 Nm

Over-current fuse and switch-off voltage peaks

Voltage data in the valve type code

Nominal voltage valve solenoid

Rated current valve solenoid

Recommended pre-fuse characteristics medium time-lag according to DIN EN 60127-1

G24

24 V DC

0.95 A DC

1 A

Notice:

A fuse which corresponds to the rated current according to DIN 41571 and EN / IEC 60127 has to be connected upstream of every valve solenoid (max. 3 x Irated).

The shut-off threshold of the fuse has to match the prospective short-circuit current of the supply source.

The prospective short-circuit current of the supply source may amount to a maximum of 1500 A.

This fuse may only be installed outside the potentially explosive atmosphere or must be of an explosion-proof design.

When inductivities are switched off, voltage peaks result which may cause faults in the connected control electronics.

The voltage peak must be damped by a suitable external circuitry. We recommend a circuitry with a suppressor diode with a limitation voltage of approx. 50 V.

Dimensions

Dimensions in mm

Required surface quality of the valve contact surface

1

Name plate

2

Identical seal rings for ports A, B, P, T

3

Plug screw for valve with one solenoid

4

Mounting nut with double edge, wrench size 32

5

Plug-in connector according to EN 175301-803, design A (Cable sets, separate order, see "Accessories")

6

Porting pattern according to ISO 4401-03-02-0-05

7

Name plate sticker

8

Mating connector or cable set DS2513 for valves with connector "K4" (separate order, see "Accessories")

9

Space required to remove the cable set

10

Space required to remove the coil

Valve mounting screws (separate order)

Size

Quantity

Hexagon socket head cap screws

Material number

6

4

ISO 4762 - M5 x 50 - 10.9

(Friction coefficient μtotal = 0.09 … 0.14)

R913043758

Notice:

For reasons of stability, exclusively the specified valve mounting screws may be used.

Subplates (separate order) with porting pattern according to ISO 4401-03-02-0-05, see data sheet 45100.

Notices:

  • Subplates are no components in the sense of directive 2014/34/EU and can be used after the manufacturer of the overall system has conducted an assessment of the risk of ignition. The "G...J3" versions are free from aluminum and/or magnesium and galvanized.
  • The dimensions are nominal dimensions which are subject to tolerances.

Installation conditions

(Dimensions in mm)

Individual assembly

Bank assembly

Subplate dimensions

Minimum dimensions:
Length ≥ 64, width ≥ 58, height ≥ 25

Minimum cross-section:
Height ≥ 60, width ≥ 85

Thermal conductivity of the subplate (EN-GJS-500-7)

≥ 38 W/mK

Minimum distance between the longitudinal valve axes

≥ 55

Notice:

With respect to the hydraulic fluid temperature, please observe the “Special conditions for safe use” in chapter "Technical data".

Accessories

Mating connectors for valves with connector “K4”, without circuitry, standard, with assembled connection line (ATEX)

DS2513...ATEX

Mating connectors for valves with connector “K4”, without circuitry, standard, with assembled connection line (ATEX)

DS2513...ATEX

  • For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector”
  • Mating connectors for valves with one or two solenoids (individual connection)

Downloads

Directional spool valves, direct operated, with solenoid actuation
Data Sheet | RE23178-XN | 2021-04-01 | English, United States | PDF | 596k

Product Groups: Directional spool valves
Type WE …XN
Directional spool valves, direct operated, with solenoid actuation
Manual | RE23178-XN-B | 2021-03-01 | English | PDF | 3.3MB

Product Groups: Industrial Hydraulics
Type WE6..6X/...XN...
Explosion-protected hydraulic products for industrial and mobile applications
Brochure | R999000373 | 2017-03-01 | English | PDF | 5.8MB

Product Groups: Pumps, CD - single rod cylinder, Proportional, high-response and servo valves, Axial piston pumps, Mobile controls
Product overview

Мы предлагаем следующие способы доставки товара:

Самовывоз из пункта выдачи

Самостоятельное получение заказа в пункте выдачи. Дата и время получения заранее согласуется с менеджером магазина.
Отгрузка товара юридическим лицам осуществляется только при наличии печати или правильно оформленной и заполненной доверенности, наличии паспорта получателя.


Курьерская доставка по Москве

Доставка по адресу покупателя или до пункта приема транспортной компании в г. Москве. Дата и время доставки заранее согласуется с менеджером магазина.

Доставка транспортной компанией по России

Доставка транспортной компанией по России до пункта выдачи транспортной компании или до конечного адреса покупателя. 
 

Для расчета коммерческого предложения или получения счета на поставку оборудования и программного обеспечения Bosch Rexroth оставьте заявку в форме ниже или свяжитесь с отделом продаж по телефону +7 495 137-07-02 или электронной почте sale@boschrexroth-russia.ru. Мы гарантируем оперативный ответ на ваш запрос и предоставление наилучших условий от официального поставщика Bosch Rexroth. 

Специалист по решениям Bosch Rexroth:

  • Окажет профессиональную консультацию.
  • Сообщит вашу цену на продукцию.
  • Сообщит информацию об актуальных акциях и скидках.
  • Подскажет ближайшее к вам отделение с наличием нужной продукции.
  • Согласует с вами возможную дату и время доставки.

Запрос цены или КП

Запрос цен, наличия или консультация
Пришлем актуальную информацию по ценам, скидкам, наличию товара на складе и срокам поставки
НовостиВсе новости
Bosch Rexroth A4FO: надежность в условиях высокого давления

Гидравлическое оборудование остается важной частью современных промышленных и строительных систем. Аксиально-поршневой насос Bosch Rexroth A4FO демонстрирует, как сочетание универсальности, долговечности и инженерной точности помогает решать сложные задачи, связанные с подачей гидравлической жидкост..

17 Января, 2025
Bosh Rexroth: Эффективность и надежность в одном решении

Синхронные моментные двигатели MBT130, представляющие серию MST130+MRT130 от Bosh Rexroth, выделяются рядом особенностей, которые могут быть важны для самых различных применений в автоматизации и промышленности. Кратко о характеристиках: - Максимальный крутящий момент до 180 Нм, что позвол..

14 Декабря, 2024
Bosh Rexroth HED 5-3X: Надежный контроллер для современных систем

Гидроэлектрические реле давления поршневого типа HED 5-3X от производителя Bosh Rexroth завоевали признание среди специалистов благодаря своим выдающимся характеристикам и функциональности. Эти устройства обеспечивают надежный контроль давления в различных промышленных системах. Серия компонентов..

16 Ноября, 2024
Bosch Rexroth - новая эра измерения давления в гидравлических системах

В условиях современного производства всегда важно обеспечивать стабильность и безопасность работы гидравлических систем. Преобразователь давления HM20-2X становится эффективным решением для этой задачи. Среди ключевых характеристик HM20-2X стоит выделить следующие - Серия компонент..

14 Октября, 2024
Boschrexroth Датчик давления HED 8 OA-2X/100K14: надежность и точность в контроле давления

Датчик давления Boschrexroth HED 8 OA-2X/100K14 (арт. R901102706) используется в различных промышленных приложениях, обеспечивая высокую точность и надежность измерений давления. Он способен функционировать в строгих условиях, что делает его незаменимым инструментом для автоматизации и управления пр..

13 Сентября, 2024
Bosh Rexort - аккумуляторы HAD оптимизируют энергосистемы

В мире гидропневматических систем появилась новинка, которая уже привлекла внимание специалистов. Гидропневматические аккумуляторы серии HAD демонстрируют инновационный подход к управлению энергией и стабилизации давления в различных системах, как мобильных, так и стационарных. Высокая эффективно..

23 Августа, 2024
Bosh Rexort представило двухходовой патронный клапан!

Двухходовой патронный клапан с активным управлением LC2A Bosch Rexroth представляет собой прецизионное гидравлическое устройство, разработанное для контроля и регулирования потока рабочей жидкости в системах гидравлики. Этот клапан работает по принципу двухпозиционного управления потоком, обеспечива..

17 Июля, 2024
Bosch Rexroth - надежный партнер для вашего бизнеса в области гидравлики!

Компания Bosch Rexroth предлагает широкий спектр продукции, включая гидронасосы, гидромоторы, гидроклапана, гидроцилиндры, пневмоцилиндры, клапаны, регуляторы, датчики и многое другое. Благодаря высокому качеству продукции и многолетнему опыту работы в отрасли, Bosch Rexroth является предпочтит..

20 Июня, 2024
Как правильно выбрать насос от BOSCH REXROTH?

В мире мобильной и промышленной гидравлики, где надежность и качество стоят на первом месте, насосы Bosch Rexroth выделяются как эталон долговечности и технического совершенства. Эти изделия, зарекомендовавшие себя в России и за её пределами, стали символом немецкого качества и профессионального под..

30 Мая, 2024
Bosch Rexroth – гидравлические шестерённые насосы серии AZPF

Гидравлические шестерённые насосы серии AZPF - это оборудование, которое обеспечивает преобразование механической энергии в гидравлическую с высоким КПД. Они обладают длительным сроком службы благодаря уплотнению зазоров и высокоточной технологии производства. Приводные валы в соответствии с межд..

8 Апреля, 2024
Bosch Rexroth на выставке LogiMAT

На выставке LogiMAT компания Bosch Rexroth представила передовые компоненты, подсистемы и системные решения для автоматизации и оптимизации логистики. Среди предложений компании - практические решения для трансмиссии и рабочих функций промышленных грузовиков и автономных мобильных роботов (AMR), вкл..

22 Марта, 2024
Bosch Rexroth открывает новые возможности в управлении машинами и подключении к IoT

Bosch Rexroth предлагает одну из самых производительных систем ЧПУ на рынке. Компания является лидером в области автоматизации и устанавливают стандарты в этой области. От датчиков и сервоприводов до революционной новой платформы, Bosch Rexroth предлагает широкий спектр решений для автоматизации. ..

16 Февраля, 2024

Нет отзывов об этом товаре.

Написать отзыв

Рейтинг