Directional spool valves, direct operated, with solenoid actuation WE 10.../H
Доступно к заказу
Цена по запросу
И выбери подходящего.
Description
- Size 10
- Component series 5X
- Maximum operating pressure 315 bar
- Maximum flow 135 l/min
Features
- 4/3-, 4/2- or 3/2-way version
- Porting pattern according to ISO 4401-05-04-0-05
- Standard solenoid
- Wet-pin DC solenoids with detachable coil
- Solenoid coil is rotatable by 90°
- The coil can be changed without having to open the pressure-tight chamber
- Electrical connection as individual connection
- With manual override
- Spool position monitoring, optional
Product description
The directional valves of type WE are solenoid-actuated directional spool valves that can be used as electro-hydraulic component. They control the start, stop and direction of a flow.
The directional valves basically consist of the housing (1), one or two electronic solenoids (2), the control spool (3), and the return springs (4).
In the de-energized condition, the control spool (3) is held in the central position or in the initial position by the return springs (4).
If the wet-pin electronic solenoid (2) is supplied with power, the control spool (3) moves out of its rest position into the required end position. In this way, the required direction of flow according to the selected symbol is released.
After the electronic solenoid (2) has been switched off, the control spool (3) is pushed back into its central position or into its initial position.
A manual override (5) allows for the manual switching of the valve without solenoid energization.
For unobjectionable functioning, the hydraulic system has to be bled properly.
Type code
| 01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | ||
| 4 | WE | 10 | 5X | / | H | G24 | N9 | K4 | / | M | * |
| 01 | 4 main ports | 4 |
| 02 | Directional valve | WE |
| 03 | Size 10 | 10 |
| 04 | Symbols; for the possible version, see "Symbols/Circuit diagrams" | e.g. C |
| 05 | Component series 50 … 59 (50 … 59: unchanged installation and connection dimensions) | 5X |
| 06 | Wet-pin solenoid with detachable coil | H |
| Electrical voltages | ||
| 07 | Direct voltage 24 V Connection to AC voltage mains via control with rectifier (see" Accessories") | G24 |
| Manual override 1) | ||
| 08 | With concealed manual override | N9 |
| Electrical connection | ||
| 09 | Individual connection | |
| Without mating connector, connector according to DIN EN 175301-803 | K4 2) | |
| Spool position monitoring (For more information, see data sheet 24836) | ||
| 10 | Without position switch | no code |
| Inductive position switch type QY | ||
| Monitored spool position "b" | QYBG24 | |
| Seal material (observe compatibility of seals with hydraulic fluid used, see "Technical data") | ||
| 11 | NBR seals | M |
| 12 | Further details in the plain text | * |
| 1) | The manual override cannot be allocated a safety function and may only be used up to a tank pressure of 50 bar. |
| 2) | Mating connectors, separate order, see "Accessories" and datasheet 08006. |
Technical data
general
| Size | 10 | ||
| Weight | Valve with one solenoid | kg | 3.6 |
| Valve with two solenoids | kg | 4.7 | |
| Installation position 1) | any | ||
| Ambient temperature range | °C | -20 … +50 | |
| Storage temperature range | °C | -20 … +50 | |
| 1) | With suspended installation, higher sensitivity to contamination. Horizontal installation is recommended. |
hydraulic
| Maximum operating pressure | Port P | bar | 315 |
| Port A | bar | 315 | |
| Port B | bar | 315 | |
| Port T | bar | 210 | |
| Maximum flow | l/min | 135 | |
| Hydraulic fluid | see table "Hydraulic fluid" | ||
| Hydraulic fluid temperature range | °C | -20 … +80 | |
| Viscosity range | mm²/s | 2.8 … 500 | |
| Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1) | Class 20/18/15 | ||
| 1) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. |
| Hydraulic fluid | Classification | Suitable sealing materials | Standards | Data sheet |
| Mineral oils | HL, HLP, HLPD, HVLP, HVLPD | NBR | DIN 51524 | 90220 |
|
Important information on hydraulic fluids:
| ||||
electrical
| Voltage type | Direct voltage | ||
| Nominal voltage according to VDE 0580 | V | 24 | |
| Voltage tolerance (nominal voltage) | % | ± 10 | |
| Nominal power according to VDE 0580 | W | 38 | |
| Duty cycle | % | 100 | |
| Switching time 1) | ON (pressure change 5 %) | ms | 65 … 150 |
| ON (pressure change 95 %) | ms | 100 … 220 | |
| OFF (pressure change 5 %) | ms | 12 … 50 | |
| OFF (pressure change 95 %) | ms | 48 … 104 | |
| Switching time according to ISO 6403 | ON | ms | 45 … 60 |
| OFF | ms | 20 … 30 | |
| Maximum switching frequency | 1/h | 15000 | |
| Maximum surface temperature of the coil 2) | °C | 120 | |
| Insulation class VDE 0580 | F | ||
| Protection class according to EN 60529 | IP65 (If a suitable and a correctly mounted mating connector are used.) | ||
| Protection class according to VDE 0580 | I | ||
| Electrical fuse protection | Every solenoid must be protected individually using a suitable fuse with tripping characteristics K (inductive loads). The valve must be installed on a surface that is included in the equipotential bonding. | ||
| 1) | Measured with flow, 80 % performance limit and horizontal installation position. |
| 2) | Surface temperature > 50 °C, provide contact protection. |
Notices:
- The solenoid coils must not be painted.
- Actuation of the manual override is only possible up to a tank pressure of approx. 50 bar. Avoid damage to the bore of the manual override. (Special tool for the operation, separate order, material no. R900024943). When the manual override is blocked, the operation of the solenoid must be prevented.
- Any simultaneous actuation of 2 solenoids of one valve must be ruled out.
- You have to use connection cables that have been approved of for a working temperature of more than 105 °C.
- If the standard environmental conditions according to VDE 0580 cannot be provided, the valve must be especially protected.
(For applications outside these values, please consult us!)
Diagrams/characteristic curves
(measured with HLP46, ϑOil = 40 ±5 °C)
Δp-qV characteristic curves

Δp-qV characteristic curves

| Symbol | Direction of flow | |||
| P –A | P – B | A – T | B – T | |
| A | 4 | 4 | – | – |
| A1 | 5 | 10 | – | – |
| B | 4 | 4 | – | – |
| C | 1 | 2 | 3 | 3 |
| D | 1 | 3 | 3 | 3 |
| E | 2 | 2 | 4 | 5 |
| E171 | 14 | 14 | 5 | 15 |
| G | 6 | 6 | 5 | 7 |
| H | 8 | 8 | 3 | 4 |
| J | 2 | 2 | 4 | 5 |
| L | 2 | 2 | 4 | 5 |
| M | 1 | 1 | 3 | 5 |
| T | 4 | 4 | 7 | 9 |
| U | 2 | 2 | 4 | 5 |
| Y | 2 | 1 | 1 | 4 |
| Y11 | 2 | 1 | 1 | 4 |
Central position
| Symbol | Direction of flow | |||||
| P – A | P – B | A – T | B – T | A – P | B – P | |
| J2 | 11 | 11 | 12 | 12 | 1 | 1 |
Performance limits
(measured with HLP46, ϑOil = 40 ±5 °C)
Notice:
The specified performance limits are valid for operation with two directions of flow (e.g. from P to A and simultaneous return flow from B to T).
Due to the flow forces acting within the valves, the possible performance limit may be considerably lower with only one direction of flow (e.g. from P to A while port B is blocked).
The performance limits were determined when the solenoids were at operating temperature, at 10% undervoltage and without tank preloading.


| Characteristic curve | Symbol |
| 1 | U |
| 2 | C; D; Y; Y11 |
| 3 | G |
| 4 | M |
| 5 | L |
| 6 | H |
| 7 | J2 |
| 8 | E |
| 9 | J |
| 10 | T |
| 11 | A |
| 12 | A1 |
| 13 | B |
| 14 | E171 |
Symbols/Circuit diagrams

| 1) | Example: – Symbol E with spool position “a” ordering code ..EA.. – Symbol E with spool position “b” ordering code ..EB.. |
Notice:
Representation according to ISO 1219-1.
Hydraulic interim positions are shown by dashes.
Electrical connection
Over-current fuse and switch-off voltage peaks
| Voltage data in the valve type code | Nominal voltage valve solenoid | Rated current valve solenoid | Rated current for external miniature fuse: Medium time-lag (M) according to DIN 41571 and EN/IEC 60127 |
| G24 | 24 VDC | 1.5 ADC | 1600 mA |
Notices:
Corresponding to the rated current, a fuse according to DIN 41571 and EN/IEC 60127 has to be connected upstream of every valve solenoid (max. 3 x Irated).
The shut-off threshold of the fuse has to match the prospective short-circuit current of the supply source.
The short-circuit current of the supply source to be expected may amount to a maximum of 1500 A.
Dimensions
load errorAccessories
Connector switching amplifier with pulse width modulation (PWM)
VT-SSBA1-PWM

Connector switching amplifier with pulse width modulation (PWM)
VT-SSBA1-PWM
- Component series 1X
Mating connectors for valves with connector “K4”, without circuitry, standard
3P Z4

Mating connectors for valves with connector “K4”, without circuitry, standard
3P Z4
- For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector”
- Mating connectors for valves with one or two solenoids (individual connection)
Mating connectors for valves with connector “K4”, with indicator light
3P Z5L

Mating connectors for valves with connector “K4”, with indicator light
3P Z5L
- For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector”
- Mating connectors for valves with one or two solenoids (individual connection)
Mating connectors for valves with connector “K4”, without circuitry, standard
3P Z45

Mating connectors for valves with connector “K4”, without circuitry, standard
3P Z45
- For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector”
- Mating connectors for valves with one or two solenoids (individual connection)
Mating connectors for valves with connector “K4”, with indicator light and Zener diode suppression circuit
3P Z5L1

Mating connectors for valves with connector “K4”, with indicator light and Zener diode suppression circuit
3P Z5L1
- For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector”
- Mating connectors for valves with one or two solenoids (individual connection)
Mating connectors for valves with connector “K4”, with indicator light
3P Z55L

Mating connectors for valves with connector “K4”, with indicator light
3P Z55L
- For valves with connector “K4” according to EN 175301-803 and ISO 4400, 2-pole + PE, “large cubic connector”
- Mating connectors for valves with one or two solenoids (individual connection)
Downloads
| Directional spool valves, direct operated, with solenoid actuation Data Sheet | RE23343 | 2021-03-01 | English, United States | PDF | 475k Product Groups: Direct operated Type WE…/H |