Description

  • Component series 1X
  • Analog, Euro-card format
  • For valves: 4WRE

Features

  • Differential inputs for voltage and current
  • Four callable command value inputs, input for ramp time
  • Digital inputs for enable, ramp, inverting and command value call-up
  • Model T5 with 5 ramps and quadrant recognition
  • Adjustable ramp times, step level and maximum solenoid current
  • Reverse polarity protection for the operating voltage
  • Switchable measuring socket with version T5
  • "Ready for operation" output
  • Power supply unit with DC/DC converter without raised zero point

Product description

By closing the jumper J3, the ramp times specified above can be increased tenfold.

Characteristic curve generator [11]

Using the adjustable characteristic curve generator, step level and maximum values for positive and negative signals can be set separately, adjusted to the hydraulic requirements. The actual development of the characteristic curve through the zero point is not stepped but linear.

Amplitude limiter [12]

The internal command value is limited to approx. ±110 % of the nominal range.

Oscillator [14]

The oscillator creates the control signal for the inductive position transducer.

Demodulator [15]

The demodulator supplies the actual value signal of the valve spool position from the position transducer signal. 100 % ≙ 10 V

Position controller [17]

The position controller is optimized in a valve-specific manner.

Power output stage [16]

The current output stage creates the clocked solenoid current for the proportional valve. The solenoid current is limited to 2.5 A to 2.8 A per output. The output stage outputs are short-circuit-proof. The output stages are de-energized in case of an internal fault signal or if the enable signal is missing.

Fault recognition [17]

The position transducer cable is monitored for cable break and short-circuits on the primary side as well as for over-currents at the output stage.

[ ] = Assignment to the block diagrams

There is no switch-over between current and voltage input. The inputs are permanently available (see block diagram).

Command value call-ups [4]

Four command value signals "w1" to "w4" can be called up. The external command value voltages (command value 1 to 4) are either defined directly by the regulated voltage outputs +10 V and –10 V or by external potentiometers. If these command value inputs are directly connected to the regulated voltages, the command values are set at the potentiometers "w1" to "w4". When using external potentiometers, the internal potentiometers will function as attenuators or limiters.

Only one call-up can be operated at a time. If several call-ups are operated simultaneously, call-up 1 has the lowest priority and call-up 4 has the highest priority.

The respective active call-up is indicated by a yellow LED on the front plate.

Command value inverting [7]

The command value created internally from the input signals, the command value call-ups and the zero point offset signal can be inverted by an external signal or jumper J1. Inverting is indicated by an LED "–1" on the front plate.

Enable function [8]

The enable function enables the current output stages and forwards the internal command value signal to the ramp generator. The enable signal is indicated by an LED on the front plate. If enable is connected, the internal command value is changed (with any kind of command value presetting) by the set ramp time. Thus, a controlled valve does not open abruptly.

Ramp generator [9]

The ramp generator limits the incline of the control output. The downstream step functions and amplitude attenuators do not extend or shorten the ramp time.

Using jumper J2, the ramp time is set to a minimum (<2 ms) (ramp off).

External ramp time setting:

Using an external potentiometer, the internally set ramp time can be extended. The setting can be verified by means of the measuring socket. In case of a cable break, the internal default setting will be valid automatically.

Table for setting and measurement of the ramp time:

Power supply unit [1]

The amplifier card has a power supply unit with making current limiter. This unit supplies all internally required positive and negative supply voltages.

Command value presetting

The internal command value signal is calculated from the total (summation [6]) of the external command value signal available at the differential input [2] and at the current input [3], the called-up signal [4] and the zero point offset [5] (zero point potentiometer "Zw").

The following applies:

Value at measuring socket
"t" (T1) / "v" (T5)

U/V

5

3

2

1

0.5

0.3

0.2

0.1

0.05

0.03

0.02

Current ramp time (±20 %)

t/ms

20

33

50

100

200

333

500

1000

2000

3333

5000

Standard values

Current input

Differential input

Command value socket

Solenoid

-100 %

4 mA

-10 V

-10 V

a

0 %

12 mA

0 V

0 V

+100 %

20 mA

+10 V

+10 V

b

If the current input is not wired-up or if the cable of the current command value is broken, the resulting internal command value signal is 0%.

Type code

01

Valve amplifier for proportional flow control valves with electrical position feedback, analog, euro-card format

02

For valves: 4WRE 6...2X

For valves: 4WRE 10...2X

03

Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions)

04

Version: standard

05

Option: with one ramp time

Option: with five ramp times

06

Further details in the plain text

01

02

03

04

05

06

Technical data

Position transducer

Type / version

VT-VRPA2-1-1X...T1, VT-VRPA2-2-1X...T1VT-VRPA2-1-1X...T5, VT-VRPA2-2-1X...T5

Oscillator voltage

U

V

5 (I = 10 mA)

Oscillator frequency

f

kHz

5.6

Supplementary information

Type / version

VT-VRPA2-1-1X...T1, VT-VRPA2-2-1X...T1VT-VRPA2-1-1X...T5, VT-VRPA2-2-1X...T5

Reference voltage

Potentiometer supply

U

V

±10 ±2% (Imax = 25 mA, short-circuit-proof)

Anschlussart

48-pole male multipoint connector, DIN 41612, design F

Ambient temperature range

ϑ

°C

​0 … ​50

Storage temperature range

ϑ

°C

-25 … ​85

Weight

m

kg

0.17

Measuring sockets

Type / version

VT-VRPA2-1-1X...T1, VT-VRPA2-2-1X...T1VT-VRPA2-1-1X...T5, VT-VRPA2-2-1X...T5

Command value

"w"

Uw

V

0 ... ±10 ±2% (Imax = 2 mA)

Ramp time

"t"

Ut

V

0.02 ... 5

additional notices

See Function

Actual value

"x"

Ux

V

0 ... 10 ±2% (Imax = 2 mA)

Switchable

"v"

Uv

V

See Operating and display elements

Anzeigen

Type / version

VT-VRPA2-1-1X...T1, VT-VRPA2-2-1X...T1VT-VRPA2-1-1X...T5, VT-VRPA2-2-1X...T5

LED display

Green 1

Ready for operation

Yellow 1

Enable

Yellow 2

Inverter

Yellow 3

Ramp on

Yellow 4

4-quadrant operation

Adjustment options

Type / version

VT-VRPA2-1-1X...T1, VT-VRPA2-2-1X...T1VT-VRPA2-1-1X...T5, VT-VRPA2-2-1X...T5

Zero point calibration

%

± 30

Command value attenuator

Potentiometer input

%

0 ... 110

Amplitude attenuator 1)

for command value

%

0 ... 110

Ramp time up/down

Ramp 1

t

s

0.02 … 5

Ramp 2

t

s

0.2 … 50

Step-change height

%

0 ... 50
1)Applies to a step level setting of 0%

Solenoid outputs

Type / version

VT-VRPA2-1-1X...T1, VT-VRPA2-2-1X...T1VT-VRPA2-1-1X...T5, VT-VRPA2-2-1X...T5

Solenoid current

max.

Imax

A

2.5

Clock frequency

f

Hz

5 kHz

Solenoid output

Other properties

Short-circuit-proof, clocked

Analog outputs

Type / version

VT-VRPA2-1-1X...T1, VT-VRPA2-2-1X...T1VT-VRPA2-1-1X...T5, VT-VRPA2-2-1X...T5

Internal command value

0 ... ±10 ±2% (Imax = 2 mA)

Actual current value

0 ... 2.5 ±2% (mV ≙ mA), Imax = 2 mA

Measurement signal

0 ... ±10 ±2% (Imax = 2 mA)

Analog inputs

Type / version

VT-VRPA2-1-1X...T1, VT-VRPA2-2-1X...T1VT-VRPA2-1-1X...T5, VT-VRPA2-2-1X...T5

Command value

Voltage (differential input)

U

V

​0 ... ±10

Voltage (differential input)

Input resistance

R

≥ 50

Voltage 1)

Potentiometer input 1-4

U

V

​0 … ±10

Voltage

Input resistance

R

> 100

Current

I

mA

4 … 20

Current

Input resistance

R

Ω

100

Ramp time

extern 2)

V

0 … 10

extern

Input resistance

R

10
1)Reference potential is M0
2)Internally raised to +15 V, reference is M0

Voltage supply

Type / version

VT-VRPA2-1-1X...T1, VT-VRPA2-2-1X...T1VT-VRPA2-1-1X...T5, VT-VRPA2-2-1X...T5

Operating voltage

Nominal

U

V

24

Lower limit value

UB(t)min

V

18

Upper limit value

UB(t)max

V

35

Power consumption

max.

Smax

VA

24

Current consumption

max.

Imax

A

2

Fuse

2 A medium time-lag, exchangeable

Digital outputs

Type / version

VT-VRPA2-1-1X...T1, VT-VRPA2-2-1X...T1VT-VRPA2-1-1X...T5, VT-VRPA2-2-1X...T5

Ready for operation

On (active) 1)

U

V

16 ... UB

Off (inactive)

U

V

0 ... 1
1)Imax = 50 mA, Ri = 10 kΩ

Digital inputs

Type / version

VT-VRPA2-1-1X...T1, VT-VRPA2-2-1X...T1VT-VRPA2-1-1X...T5, VT-VRPA2-2-1X...T5

Command value call-ups

On (active) 1)

U

V

8.5 ... UB

Off (inactive)

U

V

0 ... 6.5

Enable

On (active) 1)

U

V

8.5 ... UB

Off (inactive)

U

V

0 ... 6.5

Inverter

On (active) 1)

U

V

8.5 ... UB

Off (inactive)

U

V

0 ... 6.5

Ramp call-ups

On (active)

U

V

8.5 ... UB 1)

Off (inactive)

U

V

0 ... 6.5

4-quadrant operation

On (active)

U

V

8.5 ... UB 1)

Off (inactive)

U

V

0 ... 6.5
1)Re > 100 kΩ

General

Type / version

VT-VRPA2-1-1X...T1, VT-VRPA2-2-1X...T1VT-VRPA2-1-1X...T5, VT-VRPA2-2-1X...T5

Component series

1X

Type of electronics

Analog

Design

Euro-card

(For applications outside these values, please consult us!)

Notice:

For information on the environment simulation testing for the areas EMC (electro-magnetic compatibility), climate and mechanical load, see data sheet 30119-U.

Operating and display elements

For more information, refer to document 30119-B.

Zw

Zero point setting

w1

Attenuator command value 1

w2

Attenuator command value 2

w3

Attenuator command value 3

w4

Attenuator command value 4

t

Ramp time

Gw+

Amplitude attenuator for positive command values

Gw-

Amplitude attenuator for negative command values

S+

Step level for positive direction

S-

Step level for negative direction

The warranty expires if the sealed potentiometer is adjusted.

Actual value

Command value

Ramp time

Reference potential

Ready for operation (green)

Enable (yellow)

-1

External inverter

w1...w4

Command value call-ups

Jumper

Function

Jumper

Factory setting

Inverter

inverting

not inverting

Ramp

off

on

Ramp time

0.2 ... 50 s

0.02 ... 5 s

Step function

off

on

Measuring socket "v"

Signal designation

Measuring point selector switch

Measurement signal

Internal command value

0

±10 V ≙ ±100 %

Command value 1

1

±10 V ≙ ±100 %

Command value 2

2

±10 V ≙ ±100 %

Command value 3

3

±10 V ≙ ±100 %

Command value 4

4

±10 V ≙ ±100 %

Zero point command value

5

±3 V ≙ ±30 %

Sum of the command values

6

±10 V ≙ ±100 %

Ramp output signal

7

±10 V ≙ ±100 %

Zero point actual value

8

±10 V ≙ ±30 %

9

Ramp time 1

A

10 mV ... 10 V 1)

Ramp time 2

B

10 mV ... 10 V 1)

Ramp time 3

C

10 mV ... 10 V 1)

Ramp time 4

D

10 mV ... 10 V 1)

Ramp time 5

E

10 mV ... 10 V 1)

Current ramp time (±20 %)

F

10 mV ... 10 V 1)

1) The assignments between voltage and ramp time specified in the Function section apply.

Potentiometer

Zero point setting

Attenuator command value 1

Attenuator command value 2

Attenuator command value 3

Attenuator command value 4

Ramp time 1

Ramp time 2

Ramp time 3

Ramp time 4

Amplitude attenuator for positive command values

Amplitude attenuator for negative command values

Step level for positive direction

Step level for negative direction

The warranty expires if the sealed potentiometer is adjusted.

Measuring sockets

Actual value

Command value

Switchable measuring points

Reference potential

LED displays

Ready for operation (green)

Enable (yellow)

-1

External inverter

4Q

4-quadrant operation

T

reserved

w1...w4

Command value call-ups

t1...t4

Ramp time call-ups

Symbols/Circuit diagrams

Power supply unit

Differential input

Current input

Command value selection logics

Zero point setting

Summing device

Command value inversion

Enable

Ramp generator

Characteristic curve generator

Amplitude limiter

Command value output

Oscillator

Demodulator

Actual value output

Position controller

Power output stage

Fault recognition

Power supply unit

Differential input

Current input

Command value selection logics

Zero point setting

Command value summation

Command value inversion

Enable

Ramp generator

Ramp time selection logics

Characteristic curve generator

Amplitude limiter

Command value output

Oscillator

Demodulator

Actual value output

Position controller

Power output stage

Fault recognition

Measuring point switch-over

Dimensions

Type M-.SMR…

Dimensions in mm

Dimensions in mm

Downloads

Analoge Verstärkerkarte VT-VRPA2-.-1X/V0/T., Inbetriebnahmeanleitung
Manual | RD30119-B | 2004-03-01 | German | PDF | 616k

Product Groups: Valve amplifiers
Analog Amplifier Card VT-VRPA2-.-1X/V0/T. Commissioning instructions
Manual | RE30119-B | 2004-03-01 | English | PDF | 664k

Product Groups: Valve amplifiers
方向制御弁用ユーロカード形アナログアンプ
Data Sheet | RJ30119 | 2013-04-30 | Japanese | PDF | 265k

Product Groups: Valve amplifiers
VT-VRPA2
Ventilverstärker für Proportional-Wegeventile
Data Sheet | RD30119 | 2013-04-23 | German | PDF | 253k

Product Groups: Valve amplifiers
VT-VRPA2-...1X
Valve amplifier for proportional directional valves
Data Sheet | RE30119 | 2013-04-25 | English | PDF | 259k

Product Groups: Valve amplifiers
VT-VRPA2
Amplificateur de valve pour distributeurs proportionnels
Data Sheet | RF30119 | 2013-04-25 | French | PDF | 257k

Product Groups: Valve amplifiers
VT-VRPA2
Amplificador de válvula para válvulas proporcionales direccionales
Data Sheet | RS30119 | 2013-04-25 | Spanish | PDF | 262k

Product Groups: Valve amplifiers
VT-VRPA2
用于比例方向阀的阀放大器
Data Sheet | RC30119 | 2013-04-30 | Chinese | PDF | 572k

Product Groups: Valve amplifiers
VT-VRPA2-.-1X/…
Declaration on environmental compatibility in the fields of EMC, climate and mechanical stress
Data Sheet | RE30119-U | 2004-11-01 | English | PDF | 89k

Product Groups: Valve amplifiers
Type VT-VRPA2-,-1X/...
Erklärung zur Umweltverträglichkeit für die Bereiche EMV, Klima und mechanischer Belastung
Data Sheet | RD30119-U | 2004-11-01 | German | PDF | 89k

Product Groups: Valve amplifiers
Typ VT-VRPA2-,-1X/...

Мы предлагаем следующие способы доставки товара:

Самовывоз из пункта выдачи

Самостоятельное получение заказа в пункте выдачи. Дата и время получения заранее согласуется с менеджером магазина.
Отгрузка товара юридическим лицам осуществляется только при наличии печати или правильно оформленной и заполненной доверенности, наличии паспорта получателя.


Курьерская доставка по Москве

Доставка по адресу покупателя или до пункта приема транспортной компании в г. Москве. Дата и время доставки заранее согласуется с менеджером магазина.

Доставка транспортной компанией по России

Доставка транспортной компанией по России до пункта выдачи транспортной компании или до конечного адреса покупателя. 
 

Для расчета коммерческого предложения или получения счета на поставку оборудования и программного обеспечения Bosch Rexroth оставьте заявку в форме ниже или свяжитесь с отделом продаж по телефону +7 495 137-07-02 или электронной почте sale@boschrexroth-russia.ru. Мы гарантируем оперативный ответ на ваш запрос и предоставление наилучших условий от официального поставщика Bosch Rexroth. 

Специалист по решениям Bosch Rexroth:

  • Окажет профессиональную консультацию.
  • Сообщит вашу цену на продукцию.
  • Сообщит информацию об актуальных акциях и скидках.
  • Подскажет ближайшее к вам отделение с наличием нужной продукции.
  • Согласует с вами возможную дату и время доставки.

Запрос цены или КП

Запрос цен, наличия или консультация
Пришлем актуальную информацию по ценам, скидкам, наличию товара на складе и срокам поставки
НовостиВсе новости
Bosch Rexroth A4FO: надежность в условиях высокого давления

Гидравлическое оборудование остается важной частью современных промышленных и строительных систем. Аксиально-поршневой насос Bosch Rexroth A4FO демонстрирует, как сочетание универсальности, долговечности и инженерной точности помогает решать сложные задачи, связанные с подачей гидравлической жидкост..

17 Января, 2025
Bosh Rexroth: Эффективность и надежность в одном решении

Синхронные моментные двигатели MBT130, представляющие серию MST130+MRT130 от Bosh Rexroth, выделяются рядом особенностей, которые могут быть важны для самых различных применений в автоматизации и промышленности. Кратко о характеристиках: - Максимальный крутящий момент до 180 Нм, что позвол..

14 Декабря, 2024
Bosh Rexroth HED 5-3X: Надежный контроллер для современных систем

Гидроэлектрические реле давления поршневого типа HED 5-3X от производителя Bosh Rexroth завоевали признание среди специалистов благодаря своим выдающимся характеристикам и функциональности. Эти устройства обеспечивают надежный контроль давления в различных промышленных системах. Серия компонентов..

16 Ноября, 2024
Bosch Rexroth - новая эра измерения давления в гидравлических системах

В условиях современного производства всегда важно обеспечивать стабильность и безопасность работы гидравлических систем. Преобразователь давления HM20-2X становится эффективным решением для этой задачи. Среди ключевых характеристик HM20-2X стоит выделить следующие - Серия компонент..

14 Октября, 2024
Boschrexroth Датчик давления HED 8 OA-2X/100K14: надежность и точность в контроле давления

Датчик давления Boschrexroth HED 8 OA-2X/100K14 (арт. R901102706) используется в различных промышленных приложениях, обеспечивая высокую точность и надежность измерений давления. Он способен функционировать в строгих условиях, что делает его незаменимым инструментом для автоматизации и управления пр..

13 Сентября, 2024
Bosh Rexort - аккумуляторы HAD оптимизируют энергосистемы

В мире гидропневматических систем появилась новинка, которая уже привлекла внимание специалистов. Гидропневматические аккумуляторы серии HAD демонстрируют инновационный подход к управлению энергией и стабилизации давления в различных системах, как мобильных, так и стационарных. Высокая эффективно..

23 Августа, 2024
Bosh Rexort представило двухходовой патронный клапан!

Двухходовой патронный клапан с активным управлением LC2A Bosch Rexroth представляет собой прецизионное гидравлическое устройство, разработанное для контроля и регулирования потока рабочей жидкости в системах гидравлики. Этот клапан работает по принципу двухпозиционного управления потоком, обеспечива..

17 Июля, 2024
Bosch Rexroth - надежный партнер для вашего бизнеса в области гидравлики!

Компания Bosch Rexroth предлагает широкий спектр продукции, включая гидронасосы, гидромоторы, гидроклапана, гидроцилиндры, пневмоцилиндры, клапаны, регуляторы, датчики и многое другое. Благодаря высокому качеству продукции и многолетнему опыту работы в отрасли, Bosch Rexroth является предпочтит..

20 Июня, 2024
Как правильно выбрать насос от BOSCH REXROTH?

В мире мобильной и промышленной гидравлики, где надежность и качество стоят на первом месте, насосы Bosch Rexroth выделяются как эталон долговечности и технического совершенства. Эти изделия, зарекомендовавшие себя в России и за её пределами, стали символом немецкого качества и профессионального под..

30 Мая, 2024
Bosch Rexroth – гидравлические шестерённые насосы серии AZPF

Гидравлические шестерённые насосы серии AZPF - это оборудование, которое обеспечивает преобразование механической энергии в гидравлическую с высоким КПД. Они обладают длительным сроком службы благодаря уплотнению зазоров и высокоточной технологии производства. Приводные валы в соответствии с межд..

8 Апреля, 2024
Bosch Rexroth на выставке LogiMAT

На выставке LogiMAT компания Bosch Rexroth представила передовые компоненты, подсистемы и системные решения для автоматизации и оптимизации логистики. Среди предложений компании - практические решения для трансмиссии и рабочих функций промышленных грузовиков и автономных мобильных роботов (AMR), вкл..

22 Марта, 2024
Bosch Rexroth открывает новые возможности в управлении машинами и подключении к IoT

Bosch Rexroth предлагает одну из самых производительных систем ЧПУ на рынке. Компания является лидером в области автоматизации и устанавливают стандарты в этой области. От датчиков и сервоприводов до революционной новой платформы, Bosch Rexroth предлагает широкий спектр решений для автоматизации. ..

16 Февраля, 2024

Нет отзывов об этом товаре.

Написать отзыв

Рейтинг