Description
- Lightweight precision housing (aluminum)
- Super Linear Bushings SH
- Compensate for misalignments of up to 30 ft
- Fully sealed
- Secured with bolt
Features
- Relubricatable
Technical data
General technical data
| Ø d | mm | 20 | 25 | 30 | 40 | 50 |
| amax | m/s² | 150 | ||||
| vmax | m/s | 5 | ||||
| m | kg | 0.37 | 0.73 | 1.1 | 1.95 | 3.25 |
| FR 1) | N | 4 | 4.5 | 6 | 7.5 | 9 |
| Breakaway force | N | 7.5 | 10.5 | 13.5 | 18 | 22.5 |
| Radial clearance | Comes clamped to h5 shaft (lower limit) and set to zero clearance | |||||
| Operating conditions | ||||||
| Permissible ambient temperature (min ... max) | -20 °C ... +80 °C | |||||
| 1) | Frictional drags generated by Linear Bushings with integrated wiper seals on two sides when not under radial load. The frictional drags depend on speed and lubrication. |
Load capacities and load moments
| Ød | mm | 20 | 25 | 30 | 40 | 50 |
| C 1) | N | 3530 | 6190 | 8800 | 13500 | 22300 |
| C0 1) | N | 2530 | 4530 | 7180 | 10400 | 16800 |
| 1) | The load ratings apply for the main direction of loading. |
| The load ratings are based on a total travel of 100, 00 m. When based on 50 000 m, the values in the table need to be multiplied by 1.26. |
Legend
| Symbol | Description | Unit |
| Ød | Shaft diameters | mm |
| amax | Maximum acceleration travel | m/s2 |
| C | Dynamic load capacity | N |
| C0 | Static load capacity | N |
| FR | Friction force | N |
| m | Mass | kg |
| vmax | Maximum permissible speed | m/s |
See "Technical data – Load direction factors" and the diagrams/characteristic curves section for exact values for the 4 main directions of loading.
Refer to the "Load direction factor" diagrams for load in the direction of opening.

Effect of load direction on load rating

| a) | Closed |
| b) | Open |
Main direction of loading

Load direction factors
The load ratings C and C0 apply for the load direction ρ = 0°. For all other load directions, the load ratings must be multiplied by the factors fr (dynamic load rating C) or fρ0 (static load rating C0).
Load direction factor Super SH
| Shaft | Load direction factor (dynamic load capacity) | |||||
| Ø d (mm) | ⇩ | ⇒⇐ | ⇑ | ⇩ | ⇒⇐ | ⇑ |
| 20 - 25 | 1 | 0,79 | 1 | 1 | 0,79 | 0,52 |
| 30 - 60 | 1 | 0,86 | 1 | 1 | 0,86 | 0,59 |
| Load direction factor (static load capacity) | ||||||
| 20 - 25 | 1 | 0,68 | 1 | 1 | 0,68 | 0,50 |
| 30 - 60 | 1 | 0,83 | 1 | 1 | 0,83 | 0,55 |
| | |||||
Reduced load capacity with short stroke
In case of short stroke, the service life of the shaft is less than that of the super Linear Bushing. The load ratings C specified in the tables must therefore be multiplied by the factor f.s .

| 1) | fs = factor |
| 2) | s = movement path |
Reduced load capacity with high load
The load rating is reduced under high load F. The dynamic load rating must be multiplied by the load factor f.F .

| 1) | fF = load factor |
Tolerances and guide parallelism during operation for R1706 Linear Sets and steel shaft with ready-mounted R1015 shaft support rail

| 1) | See "Tolerances" table for exact values. |
| 2) | P1, P2 = parallelism P1 and P2 |
| 3) | L = guide length |
| a) | Single or combined shaft support rails |

Tolerances and guide parallelism during operation for R1703 and R1704 Linear Sets and steel shaft with ready-mounted R1016 shaft support rail
|
| Tolerance zone of the shaft | Shaft Ød (mm) | |||||
| 20 | 25 | 30 | 40 | 50 | |||
| Tolerances (µm) 3) | H01) 4) | h6 | +20 | +20 | +20 | +20 | +20 |
| -35 | -35 | -35 | -36 | -36 | |||
| h7 | +20 | +20 | +20 | +20 | +20 | ||
| -39 | -39 | -39 | -41 | -41 | |||
| A31) | h6 | +20 | +20 | +20 | +21 | +21 | |
| -33 | -33 | -33 | -37 | -37 | |||
| h7 | +20 | +20 | +20 | +20 | +20 | ||
| -41 | -41 | -41 | -46 | -46 | |||
| Parallelism P1 2)4) | h6 | 29 | 29 | 29 | 30 | 30 | |
| h7 | 30 | 30 | 30 | 32 | 32 | ||
| Parallelism P2 2)4) | h6 | 29 | 29 | 29 | 34 | 34 | |
| h7 | 31 | 31 | 31 | 37 | 37 | ||
| 1) | Measured from center of housing. |
| 2) | With clamped and fastened guide. |
| 3) | The tolerances apply for the set with shaft and shaft support rail. |
| 4) | Single or combined shaft support rails |
Definition of dynamic load ratings
Diagrams/characteristic curves
Load direction factors

| a) | Closed |
| b) | Open |
Super Linear Bushings can be installed in any location. Choose a location that ensures that the main direction of loading is always ρ = 0°.
Dimensions

| a) | Lubricating hole M8 x 1 sealed with plastic cap |

| a) | Lubricating hole M8 x 1 sealed with plastic cap |
Dimensions
| Ød | mm | 20 | 25 | 30 | 40 | 50 |
| D | mm | 32 | 40 | 47 | 62 | 75 |
| α | ° | 54 | 55 | 60 | 52 | |
| A | mm | 60 | 75 | 86 | 110 | 127 |
| E1 | 22 mm ±0.15 | 28 mm ±0.15 | 34 mm ±0.15 | 43 mm ±0.15 | 50 mm ±0.15 | |
| E2 | 30 mm ±0.15 | 36 mm ±0.15 | 42 mm ±0.15 | 48 mm ±0.15 | 62 mm ±0.15 | |
| E3 | mm | 35 | 42 | 52 | 65 | 75 |
| E4 | mm | 35 | 45 | 52 | 60 | 75 |
| H | mm | 30 | 35 | 40 | 45 | 50 |
| Tolerance for H 1) | µm | + 8 - 16 | ||||
| H1 | mm | 60 | 72 | 82 | 100 | 115 |
| H4 | mm | 22 | 26 | 30 | 38 | 45 |
| L | mm | 47 | 59 | 69 | 81 | 101 |
| L2 | mm | 17.5 | 22 | 27 | 31 | 39 |
| M 1) | 17 mm ±0.01 | 21 mm ±0.01 | 25 mm ±0.01 | 32 mm ±0.01 | 38 mm ±0.01 | |
| N1 | mm | 42 | 50 | 55 | 67 | 78 |
| N2 | mm | 15 | 18 | 24 | 30 | |
| S | mm | 8.4 | 10.5 | 13.5 | 15.5 | 17.5 |
| S1 | M10 | M12 | M16 | M20 | ||
| S2 | mm | 6 | 8 | 10 | 12 | |
| SW | mm | 2.5 | 3 | 4 | 5 | |
| V | mm | 5 | 6.5 | 8 | 10 | 12 |
| W | mm | 9.5 | 12 | 12.8 | 16.8 | 22.1 |
| 1) | Clamped (fastened) in relation to Ø d. |
Legend
| Symbol | Description | Unit |
| Ød | Shaft diameters | mm |
| C/C0 | Main direction of loading |
Legend
| Symbol | Description | Unit |
| Ød | Shaft diameters | mm |
| C/C0 | Main direction of loading |
Project planning information
Life expectancy calculation
Mounting
General mounting instructions
Commissioning
Linear sets with Super SH Linear Bushings do not come with initial lubrication. Grease the Linear Bushings before use. Service life data is based on initial lubrication and relubricated Linear Bushings.
Maintenance
Lubrication
Certification
load errorSafety Instructions
load errorDownloads
| Linear Bushings and Shafts Manual | R320103669 | 2005-07-01 | English, French, German, Italian | PDF | 3.6MB Product Groups: Linear Bushings and Shafts | |
| Linear Bushings Catalog | R999000488 | 2015-02-01 | English | PDF | 14.9MB Product Groups: Linear Bushings and Shafts |



Нет отзывов об этом товаре.