Description
- Size 7 … 210
- Displacement 1256 … 13200 cm³/rev
- Specific torque 20 … 210 Nm/bar
- Maximum operating pressure 350 bar
Technical data
| Type / version | CA 50 | CA 70 | CA 100 | CA 140 | CA 210 | ||||||||||||||||||
| Size | 7 | 25 | 32 | 40 | 50 | 40 | 50 | 60 | 70 | 40 | 50 | 64 | 80 | 100 | 80 | 100 | 120 | 140 | 160 | 180 | 210 | ||
| Displacement | Vg | cm³/rev | 1256 | 1570 | 2010 | 2512 | 3140 | 2512 | 3140 | 3771 | 4400 | 2512 | 3140 | 4020 | 5024 | 6280 | 5024 | 6280 | 7543 | 8800 | 10051 | 11314 | 13200 |
| Max. operating pressure | pmax | bar | 350 | ||||||||||||||||||||
| Rotational speed | nmax | rpm | 400 | 350 | 280 | 400 | 320 | 275 | 240 | 400 | 390 | 310 | 270 | 340 | 275 | 245 | 220 | 150 | 135 | 115 | |||
| Specific torque | TS | Nm/bar | 20 | 25 | 32 | 40 | 50 | 40 | 50 | 60 | 70 | 40 | 50 | 64 | 80 | 100 | 80 | 100 | 120 | 140 | 160 | 180 | 210 |
Accessories
Hydraulic quick stop valve
Hägglunds VQCB 800

Hydraulic quick stop valve
Hägglunds VQCB 800
- Valid for Hägglunds CA, CB, CBP, CBM
- Maximum flow 800 l/min
- Fast response time, i.e. 100 ... 150 ms
- Maximum pressure 350 bar
- Open and closed loop
Cross-over valve
Hägglunds COCB 700, COCB 1000
Includes valves for ATEX environment

Cross-over valve
Hägglunds COCB 700, COCB 1000
Includes valves for ATEX environment
- Valid for: Hägglunds motor CA, CB, CBM
- Maximum flow 700 l/min, 1000 l/min
- Maximum pressure 350 bar
- Open and closed loop hydraulic system
Counter balance valve
Hägglunds VCBCA 480

Counter balance valve
Hägglunds VCBCA 480
- Valid for: Hägglunds motors CA, CB
- Maximum flow 480 l/min
- Maximum pressure 350 bar
Counter balance valve
Hägglunds VCBCA 1000

Counter balance valve
Hägglunds VCBCA 1000
- Valid for: Hägglunds motor CA, CB, CBM
- Maximum flow 1000 l/min
- Maximum pressure 350 bar
Freewheeling valve
Hägglunds VFWCB 600
Includes valves for ATEX environment

Freewheeling valve
Hägglunds VFWCB 600
Includes valves for ATEX environment
- Valid for: Hägglunds motor CA, CB, CBM
- Maximum flow 1000 l/min
- Nominal flow 600 l/min
- For closed and open loop hydraulic system
Free circulation valve
Hägglunds VFCCA 1000
Includes valves for ATEX environment

Free circulation valve
Hägglunds VFCCA 1000
Includes valves for ATEX environment
- Valid for: Hägglunds motor CA, CB, CBM
- Maximum flow 1000 l/min
- Maximum pressure 350 bar
- Open and closed loop hydraulic system
Four-way valve including counter balance on load line
Hägglunds V4WCA 1000

Four-way valve including counter balance on load line
Hägglunds V4WCA 1000
- Valid for: Hägglunds motor CA, CB, CBM
- Maximum flow 1000 l/min
- Maximum pressure 350 bar
2-speed valve
Hägglunds VTCA 600
Includes valves for ATEX environment

2-speed valve
Hägglunds VTCA 600
Includes valves for ATEX environment
- Valid for: Hägglunds motors CA
- Maximum flow 600 l/min
- For closed and open loop hydraulic system
Downloads
| Hägglunds CA Installation and Maintenance Manual Manual | RE15305-WA | 2019-11-06 | English | PDF | 6.5MB Product Groups: Hägglunds CA Hägglunds CA | |
| Product catalog Hägglunds CA Catalog | RE15305-01 | 2019-03-21 | English | PDF | 6.5MB Product Groups: Radial piston motors |