High-response directional valve, direct operated, with integrated digital axis controller (IAC Multi Ethernet) 4WRPDH
Доступно к заказу
Цена по запросу
И выбери подходящего.
Description
- Size 6, 10
- Component series 2X
- Maximum operating pressure 350 bar
- Maximum flow 100 l/min
Features
Product description
Set-up
The directional control valve with IAC Multi Ethernet electronics mainly consists of:
- Direct operated directional control valve (1) with control spool and sleeve in servo quality
- Integrated digital axis controller (2) with:
- analog/digital interface (XH2)
- Ethernet interfaces (X7E1, X7E2)
- analog sensor interfaces (X2M1, X2M2)
- digital sensor interface (X8M)
- Integrated digital axis controller (2) with:
Directional control valve with integrated axis controller, analog interfaces (X2M1, X2M2), digital interfaces (XH2, X8M) and Ethernet interfaces (X7E1, X7E2)
Functional description
The IAC Multi Ethernet valve (Integrated Axis Controller based on directional control valves) is a digital directional control valve with integrated axis controller and the following functionalities:
- Position control
- Pressure/force control
- Closed-loop speed control
- Substitutional closed-loop control (position - pressure/force)
- Substitutional control (flow - pressure/force)
- pQ function (flow-controlled)
This enables, amongst others, the following operating modes:
- Valve direct control
- Drive-controlled position control
- Drive-controlled positioning
- Positioning block operation
- The command values are preset via the Ethernet interface (X7E1 or X7E2) or, alternatively, via the analog/digital interface (XH2)
- The feedback information of the actual value signals to the superior control system is provided optionally either via the Ethernet interface (X7E1 or X7E2) or the analog/digital interface (XH2)
- The controller parameters are set via the Ethernet interface (X7E1 or X7E2)
Monitoring
The digital control electronics enable comprehensive monitoring functions/error detection including:
- Undervoltage
- Communication error
- Cable break for analog sensor inputs and digital position measurement system
- Short-circuit monitoring for analog/digital outputs
- Monitoring of the microcontroller (watchdog)
- Temperature of the integrated electronics
IndraWorks DS PC program
To implement the project planning task and to parameterize the IAC Multi Ethernet valves, the user may use the IndraWorks DS engineering tool (see accessories):
- Project planning
- Parameterization
- Commissioning
- Diagnosis
- Comfortable management of all data on a PC
- PC operating systems: Windows XP (SP3), Windows 7
Safety function
The integrated control electronics of the valve enables the additional shut-off of a channel according to EN 13849-1 in the direction P to A (depending on the application, the fail-safe position must be adhered to).
For this purpose, a suitable control system must be provided to perform the plausibility check between the direction-dependent valve signals "enable input" and "enable acknowledgement" (signal fed back by the valve).
It is not possible to switch off direction P to B in a safety-relevant manner according to EN 13849-1 (depending on valve type).
Type code
01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | |||
4 | WRP | D | H | B | ‒ | 2X | / | / | 24 | D6 | * |
01 | 4 main ports | 4 | |||
02 | High-response directional valves | WRP | |||
03 | With integrated digital axis controller | D | |||
04 | Control spool/sleeve | H | |||
05 | Size 6 | 6 | |||
Size 10 | 10 | ||||
06 | Symbols; for the possible version, see "Symbols/Circuit diagrams" | ||||
07 | Installation side of the inductive position transducer | B | |||
Rated flow (Δp = 35 bar/control edge) | |||||
08 | Flow characteristic | ||||
„L" | "P" (inflection 40 %) | "P" (inflection 60 %) | |||
Size 6 | |||||
2 l/min | ✔ | ‒ | ‒ | 02 | |
4 l/min | ✔ | ✔ | ‒ | 04 | |
12 l/min | ✔ | ‒ | ‒ | 12 | |
15 l/min | ‒ | ‒ | ✔ | 15 | |
24 l/min | ✔ | ‒ | ‒ | 24 | |
25 l/min | ‒ | ‒ | ✔ | 25 | |
40 l/min | ✔ | ✔ | ‒ | 40 | |
Size 10 | |||||
50 l/min | ✔ | ✔ | ‒ | 50 | |
100 l/min | ✔ | ✔ | ‒ | 100 | |
Flow characteristic | |||||
09 | Linear | L | |||
Inflected characteristic curve (inflection 60 % for NG6 with rated flows "15" and "25", otherwise inflection 40 %) | P | ||||
10 | Component series 20 ... 29 (20 ... 29: unchanged installation and connection dimensions) - Size 6 | 2X | |||
Seal material (observe compatibility of seals with hydraulic fluid used, see "Technical data") | |||||
11 | NBR seals | M | |||
FKM seals | V | ||||
12 | Supply voltage 24 V | 24 | |||
Ethernet interface | |||||
13 | EtherNet/IP | E | |||
PROFINET RT | N | ||||
Sercos | S | ||||
EtherCAT (Profil CANopen) | T | ||||
POWERLINK (CANopen profile) | W | ||||
VARAN | V | ||||
Electrical interface | |||||
14 | ±10 VDC or 4 … 20 mA | D6 | |||
Sensor interfaces | |||||
15 | 0 … 10 V / 4 … 20 mA / EnDat 2.2 | S | |||
0 … 10 V / 4 … 20 mA / SSI | T | ||||
0 … 10 V / 4 … 20 mA / 1Vpp | U | ||||
16 | Further details in the plain text | * |
Technical data
(For applications outside these values, please consult us!)
general
Size | 6 | 10 | ||
Earth | kg | 3.2 | 7.2 | |
Installation position | Any | |||
Storage temperature range | °C | +5 … +40 | ||
Ambient temperature range | °C | -20 … +60 | ||
Sine test according to DIN EN 60068-2-6 | 10 ... 2000 Hz / maximum 10 g / 10 cycles / 3 axes | |||
Noise test according to DIN EN 60068-2-64 | 20 ... 2000 Hz / 10 gRMS / 30 g peak / 30 min / 3 axes | |||
Transport shock according to DIN EN 60068-2-27 | 15 g / 11 ms / 3 axes | |||
Maximum relative humidity 1) | % | 95 | ||
Maximum surface temperature | °C | 150 | ||
MTTFD values according to EN ISO 13849 2) | Hydraulic (category 1) | Years | 150 |
1) | No condensation |
2) | For further details, please refer to operating instructions 29391-B |
hydraulic
Size | 6 | 10 | ||
Maximum operating pressure | Port P | bar | 350 | 315 |
Anschluss A | bar | 350 | 315 | |
Port B | bar | 350 | 315 | |
Port T | bar | 250 | ||
Maximum flow | l/min | 100 | ||
Hydraulic fluid | see table "Hydraulic fluid" | |||
Hydraulic fluid temperature range | °C | -20 … +60 | ||
Viscosity range | Maximum admissible | mm²/s | 10 … 800 | |
Recommended | mm²/s | 20 … 100 | ||
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1) | Class 18/16/13 |
1) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. |
hydraulic
Size | 6 | 10 | ||||||||||
Nominal flow 1) | l/min | 2 | 4 | 12 | 15 | 24 | 25 | 40 | 50 | 100 | ||
Limitation of use | Symbols C3, C5 | bar | 350 | 160 | 315 | 160 | ||||||
Symbols C1, C4 | bar | 350 | 280 | 250 | 100 | 250 | 100 | |||||
Leakage flow (at 100 bar) | Linear characteristic curve “L” | l/min | < 150 | < 180 | < 300 | - | < 500 | < 900 | < 1200 | < 1500 | ||
Inflected characteristic curve "P" | l/min | - | < 180 | < 300 | < 450 | < 600 2) | < 500 3) | < 600 |
1) | With Δp = 35 bar/control edge; flow for deviating Δp see formula. |
2) | 1:1 |
3) | 2:1 |
Hydraulic fluid | Classification | Suitable sealing materials | Standards | Data sheet | |
Mineral oils | HL, HLP, HLPD, HVLP, HVLPD | NBR, FKM | DIN 51524 | 90220 | |
Bio-degradable | Insoluble in water | HETG | NBR, FKM | ISO 15380 | 90221 |
HEES | FKM | ||||
Soluble in water | HEPG | FKM | ISO 15380 | ||
Flame-resistant | Water-free | HFDU (glycol base) | FKM | ISO 12922 | 90222 |
HFDU (ester base) | FKM | ||||
HFDR | FKM | ||||
Containing water | HFC (Fuchs: Hydrotherm 46M, Renosafe 500; | NBR | ISO 12922 | 90223 | |
Important information on hydraulic fluids:
|
static / dynamic
Hysteresis | % | ≤ 0.2 |
Manufacturing tolerance | % | ≤ 10 |
Temperature drift | %/10 K | Zero shift < 0.25 |
Pressure drift | %/100 bar | Zero shift < 0.15 |
Zero point calibration (set in the plant) | % | ± 1 |
electrical
Size | 6 | 10 | ||
Power supply | Nominal voltage 1) | VDC | 24 | |
Lower limit value | VDC | 18 | ||
Upper limit value | VDC | 36 | ||
Maximum residual ripple 2) | Vpp | 2.5 | ||
Relative duty cycle 3) | % | 100 | ||
Current consumption | Maximum 4) | A | 2.5 | |
Impulse current | A | 4 | ||
Required fuse protection, external | A | 4, time-lag | ||
Maximum power consumption | W | 40 | 60 | |
Protection class according to EN 60529 | IP65 (If a suitable and a correctly mounted mating connector are used.) | |||
AD/DA resolution | Analog inputs | bits | 12 | |
Analog outputs | bits | 10 | ||
Protective earthing conductor and screening | see pin assignment under "Electrical connection" (CE-compliant installation) | |||
Adjustment | Calibrated in the plant, see "characteristic curves" | |||
Parameterization interface | Ethernet | |||
Scan time pressure and force controller (minimum) | ms | 0.5 | ||
Scan time position controller (minimum) | ms | 1 | ||
Booting time | s | < 15 | ||
Conformity | CE according to EMC Directive 2004/108/EC tested according to EN 61000-6-2 and EN 61000-6-3 |
1) | Supply voltage is used directly for sensor connections X2M1, X2M2 and X8M (no internal voltage limitation). Voltage limit values must be observed directly at the connector of the valve (observe line length and cable cross-section). |
2) | Observe the absolute limit values of the supply voltage. |
3) | Continuous operation |
4) | The maximum current consumption will increase when using the sensor inputs or the switching output according to the external load |
electrical, integrated electronics (OBE)
Digital inputs XH2 | Quantity |
| optionally up to 2, configurable (analog inputs are no longer required) |
Low level | V | -3 ... +5 | |
High level | V | 15 ... UB | |
Current consumption at high level | mA | < 1 | |
Reference potential |
| Pin 5 | |
Digital outputs XH2 | Quantity |
| 1 |
Low level | V | 0 ... 3 | |
High level | V | 15 ... UB | |
Maximum current carrying capacity | A | 1.5 (short-circuit-proof) | |
Signal delay time | ms | < 2 (depending on set scan time) | |
Reference potential |
| GND | |
Analog inputs XH2 | Number (current and voltage input parameterizable) |
| optionally up to 2, configurable (digital inputs are no longer required) |
AD resolution | bit | 12 | |
Voltage inputs (differential inputs) | |||
Measurement range | V | -10 ... +10 | |
Input resistance | kΩ | 80 + 10 % | |
Temperature drift | mV/10 K | <14 | |
Current inputs (reference to AGND) | |||
Input current | mA | 4 ... 20 (0 ... 20 physically) | |
Input resistance | Ω | 200, measuring resistance plus FET | |
Temperature drift | μA/10 K | <25 | |
Analog outputs XH2 | Number (current and voltage input parameterizable) |
| 1 |
DA resolution | bit | 14 | |
Voltage outputs | |||
Output range | V | -10 ... + 10 (0 ... 10 durch Software) | |
Minimum load impedance | kΩ | 10 | |
Temperature drift | mV/10 K | <5 | |
Current outputs | |||
Output range | mA | 0 ... 20 (4 … 20 by software) | |
Maximum load | Ω | 200 | |
Analog sensors X2M1, X2M2 | Number (current and voltage input parameterizable) |
| 1 pro Stecker |
Power supply | V | 24 (corresponding to supply voltage applied to XH2) | |
Maximum supply current | mA | 350 (total X2M1, X2M2, X8M) | |
AD resolution | bit | 12 | |
Voltage inputs | |||
Measurement range | V | 0 ... 10 | |
Input resistance | kΩ | 80 +10 % | |
Temperature drift | mV/10 K | <15 | |
Current inputs (reference to AGND) | |||
Input current | mA | 4 ... 20 (0 ... 20 physically) | |
Input resistance | Ω | 200, measuring resistance plus PTC | |
Temperature drift | μA/10 K | <10 | |
Digital sensor X8M | Power supply | V | 24 or 5 |
Maximum supply current at - 24 V | mA | 350 (total X2M1, X2M2, X8M) | |
Maximum supply current at - 5 V | mA | 250 | |
SSI-Aufnehmer | |||
Coding |
| Gray | |
Data width | Bit | 12 ... 28 | |
Transfer frequency |
| 80 kHz ... 1 MHz | |
Line receiver/driver |
| RS485 | |
Endat encoder | 2.2 | ||
Line receiver/driver |
| RS485 | |
Resolution |
| minimum 10 nm and multiple | |
1 Vpp encoder | |||
Transfer frequency | kHz | 250 |
Diagrams/characteristic curves
Symbols/Circuit diagrams
Electrical connection
Dimensions
Project planning information
Information
Downloads
Мы предлагаем следующие способы доставки товара:
Самовывоз из пункта выдачи
Самостоятельное получение заказа в пункте выдачи. Дата и время получения заранее согласуется с менеджером магазина.
Отгрузка товара юридическим лицам осуществляется только при наличии печати или правильно оформленной и заполненной доверенности, наличии паспорта получателя.
Курьерская доставка по Москве
Доставка по адресу покупателя или до пункта приема транспортной компании в г. Москве. Дата и время доставки заранее согласуется с менеджером магазина.
Доставка транспортной компанией по России
Доставка транспортной компанией по России до пункта выдачи транспортной компании или до конечного адреса покупателя.
Мы предлагаем следующие способы оплаты товара:
Оплата наличными
Оплата за наличный расчет для физических и юридических лиц. После внесения денежных средств Покупатель подписывает товаросопроводительные документы и получает кассовый чек.
Безналичная оплата
Мы работаем с физическими и юридическими лицами за безналичный расчёт со 100% предоплатой с оформлением всех предусмотренных законодательством документов. Счёт на оплату направляется Покупателю на электронную почту после запроса счета через форму на сайте либо по электронной почте. Цена на заказанный товар действительна в течение 2 дней с момента оформления Заказа.
Электронные способы
Оплата Заказа электронными способами, в т.ч. банковскими картами. Оплата Заказа данным способом доступна запросом ссылки на оплату у нашего менеджера.
Если у вас возникнут вопросы по оформлению заказа, вы можете обратиться к нам, позвонив по телефону +7 495 137-07-02 или связавшись по электронной почте sale@boschrexroth-russia.ru. Мы гарантируем оперативный ответ на ваш запрос и предоставление наилучших условий от официального поставщика Bosch Rexroth.
Мы предоставляем официальную гарантию на всю поставляемую продукцию Bosch Rexroth.
Гарантийный сервис включает в себя:
- Приемку продукции в сервисный центр для выполнения диагностики дефекта.
- Ремонт продукции.
- Доставку продукции до объекта заказчика.
- Телефон: +7 495 137-07-02
- E-mail: support@boschrexroth-russia.ru
Для расчета коммерческого предложения или получения счета на поставку оборудования и программного обеспечения Bosch Rexroth оставьте заявку в форме ниже или свяжитесь с отделом продаж по телефону +7 495 137-07-02 или электронной почте sale@boschrexroth-russia.ru. Мы гарантируем оперативный ответ на ваш запрос и предоставление наилучших условий от официального поставщика Bosch Rexroth.
Специалист по решениям Bosch Rexroth:
- Окажет профессиональную консультацию.
- Сообщит вашу цену на продукцию.
- Сообщит информацию об актуальных акциях и скидках.
- Подскажет ближайшее к вам отделение с наличием нужной продукции.
- Согласует с вами возможную дату и время доставки.
Нет отзывов об этом товаре.