Description

  • With axial piston variable displacement pump A10VSO.../32
  • Size 45 … 180
  • Component series 3X
  • Maximum operating pressure 280 bar
  • Function: Swivel angle control, Pressure control,Torque limitation, Master-Slave
  • Communication: Sercos, PROFINET, EtherCAT, EtherNET/IP, POWERLINK, VARAN, analog

Features

  • The control system is used for the electro-hydraulic control of swivel angle, pressure and power (partially optional) of an axial piston variable displacement pump.
    It consists of the following components:
  • Axial piston variable displacement pump A10VSO.../32
  • Proportional directional valve type VT-DFP. with inductive position transducer as pilot control valve. The electronics for controlling the system is included.
  • Position transducer for sensing the swivel angle
  • Pressure transducer with suitable signal level and dynamics
  • Preload valve with integrated pressure relief function SYDZ (optional)

Product description

1

Swash plate

2

Pilot control valve

3

Counter piston

4

Actuating piston

5

Spring

6

Inductive position transducer for valve position

7

Swivel angle position sensor

8

Proportional solenoid

9

Valve spool

10

Spring

11

Pre-compression volume PCV

12

Integrated electronics

14

Drive shaft

17

Connection flange

18

Through-drive "U.." closed with cover

19

Connector XH4

20

Multi Ethernet interface X7E1

21

Multi Ethernet interface X7E2

22

Configurable sensor interface X2M1

23

Configurable sensor interface X2M2

24

Reserved, X2N

25

Actual swivel angle value input X8A

Type code

01

02

03

04

05

06

07

08

09

10

11

12

13

14

15

16

17

SYDFED

3X

/

R

V

B

A

*

Pump of the control system

Series

01

Control system with internal digital electronics (Ethernet-based bus systems)

SYDFED

Pump combinations (see below)

SY2DFED
SY3DFED

02

Component series 30 … 39 (30 … 39: unchanged installation and connection dimensions)

3X

Size

045

071

100

140

180

03

Displacement cm³

45

71

100

140

180

e.g. 071

Direction of rotation looking at the drive shaft

04

Right

R

Hydraulic fluid

05

Mineral oil (HLP) according to DIN 51524

V

Drive shaft variant

06

Splined shaft profile SAE J 744

1)​

1 1/2"

1 3/4"

1 3/4"

S

Splined shaft profile SAE J 744 (higher through-drive torque)

1"

1 1/4"

R

Connection flange (Ø centering in mm)

07

ISO 4-hole

125

160

180

180

180

B

Subplate design

08

Without shock and vibration absorption (standard)

22U99-

– 2)

22U00-

Without shock and vibration absorption (high-speed)

22U99S

22U00S

With shock and vibration absorption (standard)

32U99-

32U00-

With shock and vibration absorption (high-speed)

– 2)

– 2)

32U99S

32U00S

Base pump variant

09

Standard (internal pilot oil)

0000

External supply

✔ 3)

0479

Regenerative operation with external supply

4)

0487

Regenerative operation without external supply

4)

0541

1)ANSI B92.1a-1976, 30° pressure angle, flat root, side fit, tolerance class 5.
2)Upon request
3)Not with version "22U99-"
4)Only version "22U99-"

Pilot control and preload valve

Control spool design

10

Standard

A

Installation orientation of the integrated electronics (see below and "Dimensions")

11

Radially to the pump axis

0

folded 90° in the direction of the subplate

2

Additional functions: Closed-loop control

12

Standard

A

For variable-speed drive

1)

N

Fieldbus interface

13

Sercos III

S

EtherCAT (Profil CANopen)

T

VARAN (servo drive profile)

V

EtherNet/IP

E

PROFINET RT

N

Powerlink

W

Actual pressure value input (freely configurable); Parameter setting upon delivery (see "Electrical connections")

14

Voltage input 0 … 10 V

Port XH4

V

Voltage input 0.5 … 5 V

Port X2M1

F

Pressure transducer

15

HM 20-2X/315-F-C13-0.5, measurement range 315 bar (0.5 ... 5 V) with connection cable 0.5 m for direct connection to X2M1 (only version "F")

L

Without pressure transducer

X

Preload valve with integrated pressure limitation

16

Pressure limitation 200 bar (tolerance ± 8 bar)

2)

1

Pressure limitation 250 bar (tolerance ± 10 bar)

2)

2

Pressure limitation 300 bar (tolerance ± 12 bar)

2; 3)

3

Without preload valve

X

17

Further details in the plain text

*

1)Upon request
2)The pressure limiting function of the preload valve is designed for a maximum speed of 1800 rpm for NG140 and for a maximum speed of 1500 rpm for NG180. Higher speeds are available on request. The pressure limiting function is not suitable for continuous operation.
3)Observe nominal pressure of pump system.

Installation orientation of the valve electronics

Clockwise direction of rotation

Installation orientation "0"

Installation orientation "2"

Pump combinations

(Material numbers or type designations are to be connected by means of "+")

01

02

03

04

05

06

SY2DFED

3X

/

/

+

01

Two-way pump

SY2DFED

02

Component series 30 … 39 (30 … 39: unchanged installation and connection dimensions)

3X

03

Size of the main pump

04

Size of the attachment pump or pump abbreviation if the attachment pump is not SYDFE (e.g. PGF)

05

Material number without "R9" for the main pump or type designation if material number is not known

06

Material number without "R9" for the attachment pump or type designation if material number is not known

01

02

03

04

05

SY3DFED

3X

/

+

+

01

Three-way pump

SY3DFED

02

Component series 30 … 39 (30 … 39: unchanged installation and connection dimensions)

3X

03

Material number without "R9" for the main pump or type designation if material number is not known

04

Material number without "R9" for the attachment pump or type designation if material number is not known

05

Material number without "R9" for the attachment pump or type designation if material number is not known

Example of name plate (single pump)

1

Material short text

2

Production order number

3

Designation of origin

4

Fabrication number

5

Word mark

6

Material number, serial number underneath

7

Date of production

8

Plant

9

Indication of direction of rotation

10

Production location

Notice:

Für Rückfragen zum Regelsystem sind Material-Nummer, Fertigungsauftragsnummer, Seriennummer und Fertigungsdatum notwendig.

Technical data

mechanisch und hydraulisch

Size

4571100140180

Displacement

cm³

4571100140180

Maximum speed

Standard

rpm

1800 1)1800 2)

High-speed 2)

rpm

3000255023002050-

Minimum speed

rpm

250

Maximum flow (displacement)

Maximum speed (standard)

l/min

-128180252324

Maximum speed (high-speed)

l/min

135181230308-

with nE = 1500 min-1

l/min

67.5106.7150210270

Maximum power (Δp = 280 bar)

Maximum speed (standard)

kW

-59.784118151

Maximum speed (high-speed)

kW

62.885107144-

with nE = 1500 min-1

kW

31507098125

Maximum torque (Δp = 280 bar, n0 max)

Nm

200317446624802

Maximum drive torque

Splined shaft "S" overall torque

Nm

-11041620

Maximum through-drive torque

Nm

-7781266

Splined shaft "R" overall torque

Nm

400644-

Maximum through-drive torque

Nm

365548-

Drive shaft load

Maximum axial force

N

1500240040004800800

Maximum radial force 3)

N

15001900230028002300

Weight

Pump without through-drive (incl. pilot control valve)

kg

3249717580

Additional preload valve

kg

3.36.3

In addition, in case of external supply

kg

2

Moment of inertia around drive axis

kg·m²

0.00350.00870.01850.02760.033

Filling quantity of the housing

l

11.62.232.7

Nominal pressure

bar

280

Maximum operating pressure 4)

bar

350

Operating pressure, min. (without load)

With preload valve

bar

≥ 1

Without preload valve

bar

≥ 20

External supply (20 bar) 5)

bar

> 10

Admissible inlet pressure

Standard

bar

0.8 ... 10

High-speed

bar

1 ... 10

Hydraulic fluid

Mineral oil (HLP) according to DIN 51524

Hydraulic fluid temperature range 6)

°C

-20 … +70

Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c)

Class 18/16/13 (for particle size ≤ 4/6/14 μm)
1)The values are applicable at an absolute pressure of 0.8 bar at suction opening S.
2)The value is applicable at an absolute pressure of 1.0 bar at suction opening S.
3)In case of higher radial forces, please consult us
4)See also data sheet 92714
5)In continuous operation; in case of operation below 10 bar see "Important notes on external supply".
6)For version "32U..S" 30 … 60 °C. Mineral oil HLP/HLPD 32/46 according to DIN 51524 must be used.

elektrisch

Supply voltage 1)

Nominal voltage

VDC

24

Lower limit value

VDC

18

Upper limit value

VDC

36

Maximum residual ripple 1)

Vpp

2.5

Maximum power consumption

W

40

Required fuse protection, external

4, time-lag

AD/DA resolution

Analog inputs

bits

12

Analog outputs 2)

bits

10

Actual pressure value input XH4; pin 10 and 11

Analog voltage

V

0 … 10

Analog current 3)

mA

0 … 20

Ambient temperature range at the pump

°C

​0 … +60

Storage temperature range (pump + electronics)

°C

+5 … +40

Electronics design

Integrated at pilot control valve (OBE)

Protection class according to EN 60529

Pump incl. pilot control valve

IP65 (with correctly installed electrical connection)IP65 with mounted and locked plug-in connectors
1)Supply voltage is used directly for sensor connections X2M1, X2M2 and X8M (no internal voltage limitation)
2)The outputs are parameterizable. For the condition as supplied, see "Electrical connection".
3)Maximum admissible input current 30 mA for configuration on current input.

Notices:

  • For information on the environment simulation testing for the areas EMC (electromagnetic compatibility), climate and mechanical load see data sheet 29016 (declarations on environmental compatibility).
  • With system versions with attached hoses ("0479" and "0487") please observe the information in the operating instructions, chapter "Maintenance".

Control loop quality

Swivel angle control

Pressure control

1)

Linearity tolerance

≤1.0 %

≤1.5 % (≤1.0 % 2))

Temperature error

≤0.5 % / 10 K

≤0.5 % / 10 K

Hysteresis

≤0.2 %

≤0.2 %

Repetition accuracy

≤0.2 %

≤0.2 %

1)Without considering the pump pulsation.
2)Using the integrated calibration function.

Notices:

  • ●The specified values are only valid when using the system-related components (see "Accessories").
  • At pressures <20 bar, higher tolerances have to be anticipated due to lower actuating forces.

(For applications outside these values, please consult us!)

Diagrams/characteristic curves

Transition function for pressure command value step (control spool version "A")

T95% in ms with a connected hydraulic fluid volume (lines and actuators)

Hydraulic fluid volume in l

T95% in ms

<​5

150

5 … 10

200

15 … 25

250

Notices:

  • For pressures up to 40 bar, the values of the response times are greater.
  • The specified curve shapes and control times refer to a drive speed of 1500 rpm and are only reached with an optimization of the pressure controller.

Transition function with swivel angle command value step (control spool version "A")

NG45, 71 (p = 50 bar)

Size 100 (p = 50 bar)

Size 140(p = 50 bar)

NG180 (p = 50 bar)

Symbols/Circuit diagrams

Schematic diagram : Actuating system supplied internally

1)– Using the pressure transducer HM 20 cable version:
Installation in P (pump) or MP1 (preload valve) in connection with actual pressure value input "F".
– Using an external pressure transducer:
Installation in the P1 line (preferably close to the actuator) and electrical connection via the central connector.
Using a preload valve:
Connection of the pressure transducer to P1 or MP1.

Schematic diagram : Actuating system supplied externally

1)The use of an anti-cavitation valve (check valve with 0.2 bar spring) is essential in order to prevent dry-running in the error case.
2)Pressure transducer (see table)
3)Maximum pressure limitation must be provided by the customer.
4)Observe upper limit for external pilot oil pressure (see operating instructions); recommendation 20 bar absolute.

Pressure transducer

Mounting options

Comment

HM 20-2X/315-F-C13-0.5 (cable version)

P

Only in connection with actual pressure value input "F"

HM 20-2X/...-.-K35 (connector version)

P1

Preferably close to the actuator

Important notes on external supply:

  • In the case of an actuating system with external supply, the pump adjustment will - in case of voltage failure - not switch to zero stroke but to the negative stop (displacement of 100 % flow from the system to the tank).
  • With an active fault message, it is imperative that the machine control reacts (e. g. switching off the drive motor of the pump, interrupting the external supply of the actuating system).
  • The command values for pressure and flow must always be greater than zero (pcommand ≥ 3 bar, αcommand ≥ 5 %) as due to drift or tolerances, there is no exact "zero" pressure or "zero" swivel angle. Under unfavorable conditions, smaller command value presettings can lead to cavitation.
  • The actual pressure value must not be less than 10 bar for more than 10 minutes (lubrication).

Electrical connection

XH4, central connection

Assignment of connector or mating connector and cable set

Pin

Signal

Description

Signal direction

Type of signal

Allocation in the cable set (accessories)

1

+ UB

Voltage supply

IN

24 VDC

1

Supply line 3 x 1.0 mm2

2

0 V = L0

Reference potential for the voltage supply

2

PE

Earth

Earthing connection for the electronics

green/yellow

3

DO

Switching output 24 V max. 1.5 A
Factory setting: Error signal

OUT

logic 24 V

white

Supply line 10 x 0.14 mm2 shielded (one end of the shield must be connected to the control)

4

M0

Reference potential for analog signals

yellow

5

AI2

Analog input 2
(or digital input, configuration via software)

IN

analog ±10 V (digital 24 V)

green

6

AO2

Analog output 2
Factory setting: Actual swivel angle value, normalized

OUT

analog ±10 V
or 0 ... 20 mA

Violet

7

AI1

Analog input 1
(or digital input, configuration via software)

IN

analog ±10 V (digital 24 V)

pink

8

AO1

Analog output 1
Factory setting: Actual pressure value, normalized

OUT

analog ±10 V
or 0 ... 20 mA

red

9

DI

Digital input (use freely configurable)

IN

logic 24 V

brown

10

Actual pressure value H

Actual pressure value input (analog input 8): Signal level depends on parameter setting. Factory setting dependent on pos. 13 of the ordering code: 0 … 10 V (V) or deactivated (F)

IN

analog 0 ... 10 V, 0 ... 20 mA (freely configurable)

black

11

Actual pressure value L

analog

blue

n.c.

gray

X7E1 and X7E2, Connector pin assignment for Ethernet interface (coding D), M12, 4-pole, socket

Pin

Assignment

1

TxD +

2

RxD +

3

TxD –

4

RxD –

5

Not assigned

X2M1 and X2M2, Analog configurable sensor interface (coding A), M12, 5-pole, socket

Pin

Assignment

1

+ 24 V voltage output (sensor supply)

1)​

2

Sensor signal input current (4 … 20 mA)

2)​

3

GND

4

Sensor signal input voltage (0 … 10 V)

2)​

5

Negative differential amplifier input to pin 4 (optional)

1)Maximum load capacity 50 mA, voltage output same as voltage supply connected to input XH4.
2)Only one signal input configurable per interface.

Notices:

  • X2N, reserved (not used)
  • X8A, actual swivel angle value input (coding A), M12, 5-pole, socket M12
  • Mating connectors, separate order, see "Accessories"

LED displays

LED

Interface

Sercos

EtherNet/IP

EtherCAT

PROFINET

POWERLINK

VARAN

1

X7E1

Activity

Activity

not used

Activity

not used

Activity

2

Link

Link

Link/Activity

Link

Link/Data Activity

Link

3

Electronic module

S

Network Status

Network Status

Network Status

Status/Error

Network Status

4

Module Status

Module Status

Module Status

Module Status

Module Status

Module Status

5

X7E2

Activity

Activity

not used

Activity

not used

not used

6

Link

Link

Link/Activity

Link

Link/Data Activity

not used

Displays of the Status LEDs

Module status

(LED 4)

Display status

Off

No voltage supply

Green-red, flashing

Self-test

Green, flashing

Drive ready for operation

Green

in control

Orange, flashing

Warning

Red, flashing

Error

Network Status

(LED 3)

Display status

See firmware and software description 30338-FK

Notices:

  • For the connection to the M12 sockets, we recommend using self-locking mating connectors.
  • LEDs 1, 2, 5 and 6 relate to interfaces "X7E1" and "X7E2"
    • Link: Cable plugged in, connection established (permanently lit)
    • Activity: Data sent/received (flashing)
  • The network status LED 3 (NS) indicates the status of the control communication, see firmware and software description 30338-FK.
  • Module status LED 4 relates to the electronics module.
  • For a detailed description of the diagnosis LEDs, please refer to the functional description "Rexroth HydraulicDrive HDx".

Dimensions

Installation orientation "0"

NG45 … 180

(Shaft design "S" or "R"; with universal through-drive "U.."; representation NG100)
Dimensions in mm

1

Preload valve (optional)

2

Pilot control valve attachment with clockwise direction of rotation

3

Space required to remove the mating connector

6

Space required for the connection line

Size

Version "0479" and "0487"

A1

A3 1)

A4

A5

A6

A6 I

A6 II

A8 I

A8 II

A8 III

A9

A10

A11

Z

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

45114249166432069111528414512526660100G1/4
711262571664325410415029215915030160100G1/4
1001312681664324710014730316415036060100G1/4
1401422921664325711014732718215037760100G1/4
1801422921664325711014732718215038760100G1/4
1)Version "0000" and "0541"

Notice:

Dimensions base pump (axial piston variable displacement pump A10VSO.../32) see data sheet 92714.

Installation orientation "2"

NG45 … 180

(Shaft design "S" or "R"; with universal through-drive "U.."; representation NG100)
Dimensions in mm

1

Preload valve (optional)

2

Pilot control valve attachment with clockwise direction of rotation

3

Space required to remove the mating connector

6

Space required for the connection line

Size

Version "0479" and "0487"

A1

A3 1)

A4

A5

A6

A6 I

A6 II

A8 I

A8 II

A8 III

A9

A10

A11

Z

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

45114137166432069111517214512532060100G1/4
711261451664325410415018015915034960100G1/4
1001311561664324710014719116415040560100G1/4
1401421801664325711014721518215041560100G1/4
1801421801664325711014721518215042560100G1/4
1)Version "0000" and "0541"

Combination pumps

Dimensions in mm

1

Main pump

2

Attachment pump

Main pump

Attachment pump

A10VSO 45

A10VSO 71

A10VSO 100

A10VSO 140

A10VSO 180

A1

mm

A2

mm

A3

mm

A4

mm

A1

mm

A2

mm

A3

mm

A4

mm

A1

mm

A2

mm

A3

mm

A4

mm

A1

mm

A2

mm

A3

mm

A4

mm

A1

mm

A2

mm

A3

mm

A4

mm

A10VSO 18

BR31

184

264

409

459

217

299

444

494

275

360

505

555

275

377

522

572

285

387

532

582

A10VSO 28

BR31

184

264

428

470

217

299

463

505

275

360

524

566

275

377

541

583

285

387

551

593

A10VSO 45

BR31

217

299

483

523

275

360

544

584

275

377

561

601

285

387

571

611

A10VSO 45

BR32

184

264

448

530

217

299

483

565

275

360

544

626

275

377

561

643

285

387

571

653

A10VSO 71

BR32

217

299

516

600

275

360

577

661

275

377

594

678

285

387

604

688

A10VSO 100

BR32

275

360

635

720

275

377

652

737

285

387

662

747

A10VSO 140

BR32

275

377

652

754

285

387

662

764

A10VSO 180

BR32

285

387

672

774

Ports

Size

45

71

100

140

180

B

Working line (SAE J518)

1)

Size

1″

1″

1 1/4″

1 1/4″

1 1/4″

Mounting thread (DIN 13)

M10 x 1.5; 17 deep

M14 x 2; 19 deep

Peak pressure

2)

bar

350

S

Suction line (SAE J518)

1)

Size

1 1/2″

2″

2 1/2″

2 1/2″

2 1/2″

Mounting thread (DIN 13)

M12 x 1.75; 20 deep

M12 x 1.75; 17 deep

Peak pressure

2)

bar

10

1)Dimensions according to SAE J518 only, metric mounting thread deviating from the standard.
2)Application-specific short-time pressure peaks may occur. Please observe when selecting measuring devices and fittings. Specified pressures are in bar absolute.

Dimensions in mm

Notes regarding size 71:

  • With pressure connection B, two SAE mounting connections rotated by 90° are available. SAE 1 1/4" standard pressure series, 3000 psi, for pressures up to 250 bar or SAE 1" standard pressure series, 5000 psi, for pressures up to 350 bar.
  • For operating pressures exceeding 250 bar, the pressure flange SAE 1" must be used.

Through-drives

"U52"

Flange ISO 3019-1 82-2

Hub for splined shaft acc. to ANSI B92.1a-1996 – 3/4" 11T 16/32DP 1) (SAE J744 - 19-4 (A-B))

Dimensions in mm

1)30° pressure angle, flat root, side fit, tolerance class 5

Size

A1

A2

A3

mm

mm

mm

4526438.718.5
712993817.5
1003603817.5
1403773817.5
1803873817.5

1

NG100 … 180

2

NG45, 71

3

Up to pump mounting face

Notice:

Before determining the design, please request a binding installation drawing.

"UB3"

Flange ISO 3019-2 - 100B2HW

Hub for splined shaft acc. to ANSI B92.1a-1996 – 7/8" 13T 16/32DP 1) (SAE J744 - 22-4 (B))

Dimensions in mm

1)30° pressure angle, flat root, side fit, tolerance class 5

Size

A1

A2

A3

mm

mm

mm

4526441.718
712994116.5
1003604116.5
1403774116.5
1803874116.5

1

NG100 … 180

2

NG45, 71

3

Up to pump mounting face

Notice:

Before determining the design, please request a binding installation drawing.

"UB4"

Flange ISO 3019-2 - 100B2HW

Hub for splined shaft acc. to ANSI B92.1a-1996 – 1" 15T 16/32DP 1) (SAE J744 - 25-4 (B-B))

Dimensions in mm

1)30° pressure angle, flat root, side fit, tolerance class 5

Size

A1

A2

A3

mm

mm

mm

45264
7129945.916.9
10036045.916.9
14037745.916.9
18038745.916.9

3

Up to pump mounting face

Notices:

  • Before determining the design, please request a binding installation drawing.
  • Missing dimensions on request.

"UE1"

Flange ISO 3019-2 125, 4-hole

Hub for splined shaft acc. to ANSI B92.1a-1996 – 1" 15T 16/32DP 1) (SAE J744 - 25-4 (B-B))

Dimensions in mm

1)30° pressure angle, flat root, side fit, tolerance class 5

Size

A1

A2

A3

mm

mm

mm

45264
7129945.916.9
10036045.916.9
14037745.916.9
18038745.916.9

1

NG100 … 180

2

NG45, 71

3

Up to pump mounting face

Notices:

  • Before determining the design, please request a binding installation drawing.
  • Missing dimensions on request.

"UB8"

Flange ISO 3019-2 - 160B4HW

Hub for splined shaft acc. to ANSI B92.1a-1996 – 1 1/4" 14T 12/24DP 1) (SAE J744 - 32-4 (C))

Dimensions in mm

1)30° pressure angle, flat root, side fit, tolerance class 5

Size

A1

A2

A3

mm

mm

mm

7129955.417.9
10036055.417.9
14037755.417.9
18038755.417.9

1

NG100 … 180

2

NG45, 71

3

Up to pump mounting face

Notice:

Before determining the design, please request a binding installation drawing.

"UB9"

Flange ISO 3019-2 - 180B4HW

Hub for splined shaft acc. to ANSI B92.1a-1996 – 1 1/2" 17T 12/24DP 1) (SAE J744 - 38-4 (C-C))

Dimensions in mm

1)30° pressure angle, flat root, side fit, tolerance class 5

Size

A1

A2

A3

mm

mm

mm

10036061.920.4
14037761.920.4
18038761.920.4

3

Up to pump mounting face

Notice:

Before determining the design, please request a binding installation drawing.

"UB7"

Flange ISO 3019-2 - 180B4HW

Hub for splined shaft acc. to ANSI B92.1a-1996 – 1 3/4" 13T 8/16DP 1) (SAE J744 - 44-4 (D))

Dimensions in mm

1)30° pressure angle, flat root, side fit, tolerance class 5

NG

A1

A2

A3

mm

mm

14037775
18038775

3

Up to pump mounting face

Notices:

  • Before determining the design, please request a binding installation drawing.
  • Missing dimensions on request.

"U01"

Flange ISO 3019-1 82-2

Hub for splined shaft acc. to ANSI B92.1a-1996 – 5/8" 9T 16/32DP 1) (SAE J744 - 16-4 (A))

Dimensions in mm

1)30° pressure angle, flat root, side fit, tolerance class 5

Size

A1

A2

A3

mm

mm

mm

45264
7129931.819.3
10036031.8
14037731.8
18038731.8

1

NG100 … 180

2

NG45, 71

3

Up to pump mounting face

Notices:

  • Before determining the design, please request a binding installation drawing.
  • Missing dimensions on request.

"U68"

Flange ISO 3019-1 101-2

Hub for splined shaft acc. to ANSI B92.1a-1996 – 7/8" 13T 16/32DP 1) (SAE J744 - 22-4 (B))

Dimensions in mm

1)30° pressure angle, flat root, side fit, tolerance class 5

Size

A1

A2

A3

mm

mm

mm

4526441.518.2
712994116.5
1003604116.5
1403774116.5
1803874116.5

1

NG100 … 180

2

NG45, 71

3

Up to pump mounting face

Notice:

Before determining the design, please request a binding installation drawing.

"U04"

Flange ISO 3019-1 101-2

Hub for splined shaft acc. to ANSI B92.1a-1996 – 1" 15T 16/32DP 1) (SAE J744 - 25-4 (B-B))

Dimensions in mm

1)30° pressure angle, flat root, side fit, tolerance class 5

Size

A1

A2

A3

mm

mm

mm

45264
7129945.916.9
10036045.916.9
14037745.916.9
18038745.916.9

1

NG100 … 180

2

NG45, 71

3

Up to pump mounting face

Notices:

  • Before determining the design, please request a binding installation drawing.
  • Missing dimensions on request.

"U24"

Flange ISO 3019-1 127-2

Hub for splined shaft acc. to ANSI B92.1a-1996 – 1 1/2" 17T 12/24DP 1) (SAE J744 - 38-4 (C-C))

Dimensions in mm

1)30° pressure angle, flat root, side fit, tolerance class 5

Size

A1

A2

A3

mm

mm

mm

10036061.920.4
14037770.510.5
18038770.510.5

3

Up to pump mounting face

Notice:

Before determining the design, please request a binding installation drawing.

Project planning information

  • Always shield command and actual value cables.
  • The distance to aerial lines or radios must be at least 1 m.
  • Do not lay signal lines close to power lines.
  • For amending notes on the SY(H)DFE control system, see the operating instructions.

Accessories

Through-drives

With the introduction of A10VSO, series 32, a so-called universal through-drive for combining several pump stages is used. The required components can be seen from the following table and are to be ordered separately. The pumps with universal through-drive are closed at the factory with an end cover to ensure reliable operation.

The following conditions apply to the attachment pumps listed in the table:

  • SYDFE and A10VSO with shaft "S" or "R"
  • Internal gear pump PGH with shaft "R", flange "U2", see data sheet 10223
  • Internal gear pump PGF3 with shaft "J", flange "U2", see data sheet 10213
  • External gear pump AZPF with shaft "R", front cover "R", see data sheet 10089

Flange and through-drive (see type key pump) must be the same. Check in the current data sheet of the gear pump whether the shaft ends have the same specified dimensions.

Mounting kits for universal through-drive

Main pump

SYDFE..-3X/..U..

Attachment pump

NG45
"U00"

NG71
"U99"

NG100
"U99"

NG140
"U99"

NG180
"U99"

Size and type

Through-drive

Centering

Hub

Flange designation

R902496472

R902447036

R902447038

R902447039

R902447039

NG18

SYDFE..-2X/
A10VSO / BR31

"U52"
82,55 mm
3/4″

ISO 3019-1-82-2

R902492531

R902446997

R902446999

R902447000

R902447000

NG28

"UB3"
100 mm
7/8″

ISO 3019-2
100B2HW

R902447002

R902447004

R902447005

R902447005

NG45

"UB4"
100 mm
1″

ISO 3019-2
100B2HW

R902510125

R902492823

R902488254

R902491915

R902491915

NG45

SYDFE..-3X/..U..
A10VSO / BR32

"UE1"
125 mm
1″

ISO 3019-2
125B4HW

R902447015

R902447017

R902447018

R902447018

NG71

"UB8"
160 mm
1 1/4″

ISO 3019-2
160B4HW

R902447023

R902447024

R902570425

NG100

"UB9"
180 mm
1 1/2″

ISO 3019-2
180B4HW

R902447027

R902570426

NG140

"UB7"
180 mm
1 3/4″

ISO 3019-2
180B4HW

R902570426

NG180

R902496467

R902447031

R902447033

R902447034

R902473591

PGF2, PGH2, PGH3, AZPF

"U01"
82,55 mm
5/8″

ISO 3019-1-82-2

R902496477

R902447041

R902447043

R902447044

R902447044

PGF3

"U68
101,6 mm
1″

ISO 3019-1-101-2

R902496482

R902447046

R902447048

R902447049

R902447049

PGH4

"U04"
101,6 mm
1″

ISO 3019-1-101-2

R902479709

R902463283

R902570424

PGH5

"U24"
127 mm
1 1/2″

ISO 3019-1-127-2

1)ANSI B92.1a-1976, 30° pressure angle, flat root, side fit, tolerance class 5. A mounting kit includes the flange kit and hub; a flange kit includes the flange, seals and mounting materials.

Torsionally flexible couplings for attachment to a standard electric motor

Motor

SYDFE.-3X

Frame size/characteristic

Shaft diameter in mm

NG45

Shaft R, 1"

NG71

Shaft "S" or "R", 1 1/4"

NG100

Shaft "S", 1 1/2"

NG140/180

Shaft "S", 1 3/4"

100/0
112/0

28

R901038017

132/0

38

R900772898

160/0

42

R900994283

R900228413

180/0

48

R900062159

R900240468

R900242567

200/0

55

R901038025

R901038021

R901104689

R901038048

225/0

60

R901066409

R900228375

R901050508

R900988121

250/0

65

R900988348

R900986404

R901046864

R900708084

280/0

75

R900218487

R901055216

R901052451

315/0

80

R901046894 1)

R901041730 1)

315/1

80

R901046885

1)Up to 40 °C

Accessories

Material number

Data sheet

Mating connector 12-pole for central connection XH4 without cable (assembly kit)

R900884671

08006

Mating connector 12-pole for central connection XH4 with cable set 2 x5 m

R900032356

Mating connector 12-pole for central connection XH4 with cable set 2 x20 m

R900860399

Pressure transducer HM 20-2X, measurement range 315 bar (4 ... 20 mA)

R901342029

30272

Pressure transducer HM 20-2X, measurement range 315 bar (0.1 ... 10 V)

R901342030

30272

Test device VT-PDFE-1-1X/V0/0

R900757051

29689-B

Compact power supply unit VT-NE32-1X

R90080049

29929

Ethernet connection cable M12 to RJ45 (connection X7E1 & X7E2), additional information type designation RKB0044/xxx.x (xxx.x: length in meters)

R911172135

Mating connectors for valves with round connector, 11-pole + PE

12P N11

Mating connectors for valves with round connector, 11-pole + PE

12P N11

  • For valves with round connector according to EN 175201-804, 11-pole + PE

Mating connectors for valves with round connector, 11-pole + PE, shielded, with assembled connection line

12P N11 +

Mating connectors for valves with round connector, 11-pole + PE, shielded, with assembled connection line

12P N11 +

  • For valves with round connector according to EN 175201-804, 11-pole + PE

Ordering codes

Downloads

Druck- und Förderstrom-Regelsystem
Manual | RD30017-B | 2021-11-09 | German | PDF | 3.9MB

Product Groups: Pump systems
SY(H)DFED
Pressure and flow control system
Manual | RE30017-B | 2021-11-09 | English | PDF | 3.9MB

Product Groups: Pump systems
SY(H)DFED
Rexroth HydraulicDrive, HDx-20 pump control
Manual | RE30237-Z | 2020-10-07 | English | PDF | 6.5MB

Product Groups: Axis control
Rexroth HydraulicDrive HDS-16, HDx-17 to HDx-20 Parameters
Reference Book | RE30330-PA | 2020-04-01 | English | PDF | 12.6MB

Product Groups: Axis control
Reference Book
Rexroth HydraulicDrive HDS-16, HDx-17 bis HDx-20 Parameter
Reference Book | RD30330-PA | 2020-04-01 | German | PDF | 12.7MB

Product Groups: Axis control
Referenz
Rexroth HydraulicDrive HDx-20VRS Firmware for drive controllers
Release Note | RE30330-RN | 2019-06-06 | English | PDF | 2.9MB

Product Groups: Axis control
Firmware Release Notes
Rexroth HydraulicDrive HDx-20VRS Firmware für Antriebsregelgeräte
Release Note | RD30330-RN | 2019-06-06 | German | PDF | 3MB

Product Groups: Axis control
Firmware Release Notes
Rexroth HydraulicDrive HDS-16, HDx-17 to HDx-20, Diagnostic Messages
Manual | RE30330-WA | 2020-04-01 | English | PDF | 4.9MB

Product Groups: Axis control
Reference
Rexroth HydraulicDrive HDS-16, HDx-17 bis HDx-20, Diagnosen
Manual | RD30330-WA | 2020-04-01 | German | PDF | 5MB

Product Groups: Axis control
Referenz
Rexroth HydraulicDrive HDx-20 Functions
Manual | RE30338-FK | 2020-04-01 | English | PDF | 59.1MB

Product Groups: Axis control
Rexroth HydraulicDrive HDx-20 Funktionen
Manual | RD30338-FK | 2020-04-01 | German | PDF | 59.8MB

Product Groups: Axis control
Druck- und Förderstrom-Regelsystem
Data Sheet | RD30630 | 2021-09-01 | German | PDF | 1.9MB

Product Groups: Electro-hydraulic control systems
Typ SYDFE1, SYDFEE, SYDFED, SYDFEF
Pressure and flow control system
Data Sheet | RE30630 | 2021-09-01 | English, United States | PDF | 1.9MB

Product Groups: Electro-hydraulic control systems
Type SYDFE1, SYDFEE, SYDFED, SYDFEF

Мы предлагаем следующие способы доставки товара:

Самовывоз из пункта выдачи

Самостоятельное получение заказа в пункте выдачи. Дата и время получения заранее согласуется с менеджером магазина.
Отгрузка товара юридическим лицам осуществляется только при наличии печати или правильно оформленной и заполненной доверенности, наличии паспорта получателя.


Курьерская доставка по Москве

Доставка по адресу покупателя или до пункта приема транспортной компании в г. Москве. Дата и время доставки заранее согласуется с менеджером магазина.

Доставка транспортной компанией по России

Доставка транспортной компанией по России до пункта выдачи транспортной компании или до конечного адреса покупателя. 
 

Для расчета коммерческого предложения или получения счета на поставку оборудования и программного обеспечения Bosch Rexroth оставьте заявку в форме ниже или свяжитесь с отделом продаж по телефону +7 495 137-07-02 или электронной почте sale@boschrexroth-russia.ru. Мы гарантируем оперативный ответ на ваш запрос и предоставление наилучших условий от официального поставщика Bosch Rexroth. 

Специалист по решениям Bosch Rexroth:

  • Окажет профессиональную консультацию.
  • Сообщит вашу цену на продукцию.
  • Сообщит информацию об актуальных акциях и скидках.
  • Подскажет ближайшее к вам отделение с наличием нужной продукции.
  • Согласует с вами возможную дату и время доставки.

Запрос цены или КП

Запрос цен, наличия или консультация
Пришлем актуальную информацию по ценам, скидкам, наличию товара на складе и срокам поставки
НовостиВсе новости
Bosch Rexroth открывает новые возможности в управлении машинами и подключении к IoT

Bosch Rexroth предлагает одну из самых производительных систем ЧПУ на рынке. Компания является лидером в области автоматизации и устанавливают стандарты в этой области. От датчиков и сервоприводов до революционной новой платформы, Bosch Rexroth предлагает широкий спектр решений для автоматизации. ..

16 Февраля, 2024
Bosch Rexroth и TotalEnergies объединяют свои усилия для продвижения альтернативных и экологичных гидравлических жидкостей

Bosch Rexroth и TotalEnergies (французская нефтегазовая компания) 18 декабря 2023 года подписали соглашение сотрудничестве, направленном на разработку, внедрение и маркетинг гидравлических жидкостей на водной основе, с акцентом на экологичность, огнестойкость и производительность. Данный союз отр..

11 Января, 2024
Bosch Rexroth представляет Интеллектуальный функциональный набор для обработки данных Smart Function Kit for Handling

Компания Bosch Rexroth является одним из ведущих мировых производителей и поставщиков технологий и услуг в области промышленной автоматизации. Это производитель рад представить вам свой интеллектуальный функциональный набор для обработки данных. Это инновационное оборудование, с помощью которого п..

4 Декабря, 2023
Бренд Bosch Rexroth представил миру свою разработку - оборудование IndraDrive CDB02 - BASIC для двухосевого блока управления

Bosch Rexroth, являясь ведущим производителем промышленного оборудования, не стоит на месте и разрабатывает новое оборудование. Одним из изобретений этой компании является IndraDrive CDB02 - BASIC. Это двухосевой блок управления, который предназначен для использования в различных промышленных сект..

1 Декабря, 2023
Bosch Rexroth: высокоскоростной асинхронный двигатель 1MB140 

Производитель Bosch Rexroth представил свою разработку - высокоскоростной асинхронный двигатель 1MB140. Этот продукт обладает рядом уникальных характеристик и предназначен для различных применений в промышленности. Основным назначением двигателя 1MB140 является обеспечение высокой скорости вращ..

30 Ноября, 2023
Bosch Rexroth рассказывает о характеристиках электрогидравлических насосов

Bosch Rexroth представляет электрогидравлические насосы, которые объединяют в себе преимущества электрической и гидравлической технологий. Данные насосы могут использоваться в различных отраслях промышленности, включая машиностроении, автомобильной промышленности, энергетике и других. Основная ..

29 Ноября, 2023
Bosch Rexroth представил серию высокоэффективных синхронных моментных двигателей МВТ130 

Синхронные моментные двигатели МВТ130 применяются в различных отраслях промышленности: машиностроение, автомобильной и энергетической промышленности. Это оборудование используют как дополнение к насосам, компрессорам, приводам конвейеров и другим механизмам, требующим точного управления и высокой ..

28 Ноября, 2023
Bosch Rexroth: надежные и эффективные героторные насосы подходят для решения для множества задач

Героторные насосы Bosch Rexroth — это инновационное оборудование, которое обеспечивает эффективную работу в различных областях промышленности. Они являются незаменимым компонентом в системах гидравлического привода и обеспечивают надежную и плавную работу механизмов. Принцип работы герото..

27 Ноября, 2023
Для эффективной работы гидравлических систем Bosch Rexroth представляет баллонный аккумулятор HAB2 

Баллонный аккумулятор HAB2 производства компании Bosch Rexroth — это инновационное оборудование, предназначенное для оптимизации работы гидравлических систем и обеспечения более эффективного использования энергии. Баллонный аккумулятор HAB2 выполняет несколько важных функций. Во-первых, с..

24 Ноября, 2023
Bosch Rexroth: инновационное решение для удобства и эффективности работы - выдвижная клавиатура VAK40 

Торговая марка Bosch Rexroth, является одним из мировых лидеров в области промышленной автоматизации, и представляет свою разработку - выдвижную клавиатуру VAK40. Это инновационное устройство, которое обеспечивает удобную и эффективную работу операторов в промышленных условиях. Установить выдви..

23 Ноября, 2023
Bosch Rexroth: инновационные функции и простая установка дисплея 19" VDP60

Бренд Bosch Rexroth рад представить свою разработку - дисплей 19" VDP60, который обещает стать настоящим прорывом в мире технологий. Этот дисплей не только показывает изображения высокого качества, но и предлагает ряд функций, которые помогут решить множество задач. Одним из главных свойст..

22 Ноября, 2023
Rexroth: Шестеренные насосы с внешним зацеплением – надежное решение для эффективной работы в различных отраслях

Компания Rexroth представляет шестеренные насосы с внешним зацеплением, которые являются необходимым прибором в области гидравлики. Они выполняют важную задачу – обеспечивают надежную и эффективную работу гидравлических систем в различных отраслях промышленности. Эти насосы нашли применен..

21 Ноября, 2023

Нет отзывов об этом товаре.

Написать отзыв

Рейтинг