Description

  • With axial piston variable displacement pump A10VSO.../31
  • Size 18 … 100
  • Component series 2X
  • Maximum operating pressure 280 bar
  • Function: Swivel angle control, Pressure control,Torque limitation, Speed control function, Master-Slave
  • Communication: Sercos, PROFINET, EtherNET/IP, POWERLINK, VARAN, CAN over EtherCAT, ServoDrive over EtherCAT, analog

Features

  • The control system is used for the electro-hydraulic control of swivel angle, pressure and power (partially optional) of an axial piston variable displacement pump.
    It consists of the following components:
  • Axial piston variable displacement pump A10VSO.../31
  • Proportional directional valve type VT-DFP. with integrated electronics and inductive position transducer as pilot control valve.
  • Position transducer for sensing the swivel angle
  • Pressure transducer with suitable signal level and dynamics (optional)
  • Preload valve with integrated pressure relief function SYDZ (optional)

Product description

1

Swash plate

2

Pilot valve

3

Counter piston

4

Actuating piston

5

Spring

6

Inductive position transducer for valve position

7

Swivel angle position sensor

8

Proportional solenoid

11

Integrated electronics

12

Connector X1

13

Connector X2 for connection of the HM 20 pressure transducer cable version (only with actual pressure value input "F")

15

Drive shaft

16

Connection flange

17

Subplate, optionally with through-drive

Type code

01

02

03

04

05

06

07

08

09

10

11

12

13

14

15

16

17

18

SYDFEE

2X

/

P

12

*

Pump of the control system

Series

01

Control system with internal analog electronics

SYDFEE

Pump combinations (see below)

SY2DFEE
SY3DFEE

02

Component series 20 … 29 (20 … 29: unchanged installation and connection dimensions)

2X

Size

018

028

045

071

100

03

Displacement cm³

18

28

45

71

100

Direction of rotation looking at the drive shaft

04

Right

R

Left

L

Hydraulic fluid

05

Mineral oil according to DIN 51524 (HL/HLP)

P

Drive shaft variant

06

Cylindrical with fitting key DIN 6885 (not in connection with through-drive)

Ø18

Ø22

Ø25

Ø32

Ø40

P

Splined shaft profile SAE J 744

1)​

3/4"

1 1/2"

S

Splined shaft profile SAE J 744 (higher through-drive torque)

7/8"

1"

1 1/4"

R

Connection flange (Ø centering in mm)

07

ISO 2-hole

80

100

100

125

125

A

SAE 2-hole

82,55

101,6

101,6

127

127

C

Port for working lines pressure port B and suction port S

08

SAE, laterally opposite, mounting thread metric

12

Through-drive (All through-drives with single pumps come without a hub and are operationally safe, provided with an end cover)

09

Without through-drive

N00

Centering

Attachment pump (examples)

2)​

ISO Ø100 mm

A10VSO..31 NG28/45

KD3

ISO Ø125 mm

A10VSO..31 NG71/100

KD5

SAE Ø82.55 mm

A10VSO..31 NG18, PGF2, PGH2, PGH3, AZPF

KC1

SAE Ø101.6 mm

PGH4, 1PF2G3, PGF3

KC3

SAE Ø127 mm

PGH5

KC5

Base pump variant

10

Standard (internal pilot oil)

0000

External supply

0479

External supply + regenerative operation

0487

1)ANSI B92.1a-1976, 30° pressure angle, flat root, side fit, tolerance class 5.
2)Observe the conditions for the attachment pumps.

Pilot control and preload valve

Control spool design

11

Standard (NG28 … NG100)

A

4-groove spool (NG18)

C

Installation orientation of the integrated electronics (see below and "Dimensions")

12

Radially to the pump axis

0

folded 90° in the direction of the subplate

2

Additional functions: Closed-loop control

13

Switchable pressure controller (high signal)

A

Power limitation adjustable at the OBE valve

B

Power limitation adjustable via analog input

C

Pressure controller that can be switched off (high signal)

D

Electronics assembly

14

Standard electronics with leakage oil compensation

0

Standard electronics without leakage oil compensation

1

Actual pressure value input (see "Electrical connections")

15

Current input 4 … 20 mA

Port X1

C

Voltage input 0 … 10 V

Port X1

V

Voltage input 1 … 10 V

Port X1

E

Voltage input 0.5 … 5 V

Connection X2

F

Pressure transducer

16

HM 20-2X/315-F-C13-0.5, measurement range 315 bar (0.5 ... 5 V) with connection cable 0.5 m for direct connection to X2 (only version "F"); NG18 only version "1", "2" or "3" with position 17)

L

Without pressure transducer

X

Preload valve with integrated pressure limitation

17

Pressure limitation 200 bar (tolerance ± 8 bar)

1)​

1

Pressure limitation 250 bar (tolerance ± 10 bar)

1)​

2

Pressure limitation 300 bar (tolerance ± 12 bar)

1; 2)​

3

Without preload valve

X

18

Further details in the plain text

*

1)The pressure limiting function is not suitable for continuous operation.
2)Observe nominal pressure of pump system.

Installation orientation of the valve electronics

Clockwise direction of rotation

Counterclockwise direction of rotation

Installation orientation "0"

Installation orientation "2"

Installation orientation "0"

Installation orientation "2"

Pump combinations

(Material numbers or type designations are to be connected by means of "+")

01

02

03

04

05

06

SY2DFEE

2X

/

/

+

01

Two-way pump

SY2DFEE

02

Component series 20 … 29 (20 … 29: unchanged installation and connection dimensions)

2X

03

Size of the main pump

04

Size of the attachment pump or pump abbreviation if the attachment pump is not SYDFE (e.g. PGF)

05

Material number without "R9" for the main pump or type designation if material number is not known

06

Material number without "R9" for the attachment pump or type designation if material number is not known

01

02

03

04

05

SY3DFEE

2X

/

+

+

01

Three-way pump

SY3DFEE

02

Component series 20 … 29 (20 … 29: unchanged installation and connection dimensions)

2X

03

Material number without "R9" for the main pump or type designation if material number is not known

04

Material number without "R9" for the attachment pump or type designation if material number is not known

05

Material number without "R9" for the attachment pump or type designation if material number is not known

Example of name plate (single pump)

1

Material short text

2

Production order number

3

Designation of origin

4

Fabrication number

5

Word mark

6

Material number, serial number underneath

7

Date of production

8

Plant

9

Indication of direction of rotation

10

Production location

Notice:

Für Rückfragen zum Regelsystem sind Material-Nummer, Fertigungsauftragsnummer, Seriennummer und Fertigungsdatum notwendig.

Technical data

mechanic and hydraulic

Size

18284571100

Displacement

cm³

18284571100

Maximum speed 1)

Vg max

rpm

33003000260022002000

maximum at Vg < Vg max

rpm

39003600310026002400

Minimum speed

rpm

250

Maximum flow (displacement)

nnom and Vg max

l/min

59.484117156200

nE = 1500 rpm and Vg max

l/min

274268107150

Maximum power (Δp = 280 bar)

nnom and Vg max

kW

27.739557393

nE = 1500 rpm and Vg max

kW

12.620325070

Maximum torque (Δp = 280 bar)

Nm

80.1125200316445

Maximum drive torque

Fitting key

Nm

88137200439857

Splined shaft "S" overall torque

Nm

124-1104

Maximum through-drive torque

Nm

108-778

Splined shaft "R" overall torque

Nm

-225400644-

Maximum through-drive torque

Nm

-176365548-

Drive shaft load

Maximum axial force

N

7001000150024004000

Maximum radial force

N 2)

3501200150019002300

Weight

Pump without through-drive (incl. pilot control valve)

kg

15.520.52637.552

Pump with through-drive (incl. pilot control valve)

kg

16.52227.540.558

Additional preload valve

kg

3.36.3

In addition, in case of external supply

kg

2

Moment of inertia around drive axis

kg·m²

0.00090.00170.00330.00830.0167

Filling quantity of the housing

l

0.40.711.62.2

Maximum operating pressure 3)

bar

280

Operating pressure, min. (without load)

With preload valve

bar

≥ 1

Without preload valve

bar

≥ 20

External supply (20 bar) 4)

bar

> 10

Admissible inlet pressure

bar

0.8 ... 10

Hydraulic fluid

Mineral oil (HL, HLP) to DIN 51524

Hydraulic fluid temperature range

°C

-20 … +70

Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c)

Class 18/16/13 (for particle size ≤ 4/6/14 μm)
1)The values apply:
– to a perfect viscosity range from 36 … 16 mm2/s
– with hydraulic fluids on the basis of mineral oils
– with an absolute pressure of 1 bar at the suction opening S.
With a reduction of the displacement or an increase in the inlet pressure, the speed can be increased according to the following characteristic curve.
With a reduced inlet pressure, the speed is to be reduced.
2)In case of higher radial forces, please consult us
3)In case of higher pressures, please consult us
4)In continuous operation; in case of operation below 10 bar see "Important notes on external supply".

elektrisch

Operating voltage

VDC

24; –5 % +40 %

Operating range (short-time operation)

Upper limit value

V

35

Lower limit value

V

21

Current consumption (in static control operation)

Rated current

A

0.6

Maximum current

A

1.25

Inputs

Actual pressure value input X1;
pin 10 and 11

Determination by means of ordering code

Analog, current, load

Ω

100

Analog, voltage

≥50

Digital

Logic 0

V

≤0,6

Logic 1

V

≥21

Outputs

pActual

V

0 ... 10

mA

1,5

αActual

V

±10

mA

1,5

Digital

Logic 0

Ua < 1 V

Logic 1

Ua ≥ UB – 5 V; 10 mA (short-circuit-proof)

Ambient temperature range at the pump

°C

​0 … +60

Storage temperature range (pump + electronics)

°C

​0 … +70

Electronics design

Integrated at pilot control valve (OBE)

Protection class according to EN 60529

Pump incl. pilot control valve

IP65 (with correctly installed electrical connection)

Notices:

  • For information on the environment simulation testing for the areas EMC (electromagnetic compatibility), climate and mechanical load see data sheet 29016 (declarations on environmental compatibility).
  • With system versions with attached hoses ("0479" and "0487") please observe the information in the operating instructions, chapter "Maintenance".

Control loop quality

Swivel angle control

Pressure control

1)

Linearity tolerance

≤1.0 %

≤1.5 % (≤1.0 %)

Temperature error

≤0.5 % / 10 K

≤0.5 % / 10 K

Hysteresis

≤0.2 %

≤0.2 %

Repetition accuracy

≤0.2 %

≤0.2 %

1)Without considering the pump pulsation.

Notices:

  • ●The specified values are only valid when using the system-related components (see "Accessories").
  • At pressures <20 bar, higher tolerances have to be anticipated due to lower actuating forces.

(For applications outside these values, please consult us!)

Diagrams/characteristic curves

Vg-n characteristic curves

Transition function for pressure command value step (control spool version "A")

T95% in ms with a connected hydraulic fluid volume (lines and actuators)

Hydraulic fluid volume in l

T95% in ms

<​5

150

5 … 10

200

15 … 25

250

Notices:

  • For pressures up to 40 bar, the values of the response times are greater.
  • The specified curve shapes and control times refer to a drive speed of 1500 rpm and are only reached with an optimization of the pressure controller.

Transition function with swivel angle command value step (control spool version "A")

Size 18 … 71 (p = 20 bar)

Size 18 … 71 (p = 50 bar)

Size 100 (p = 50 bar)

Symbols/Circuit diagrams

Schematic diagram : Actuating system supplied internally

1)– Using the pressure transducer HM 20 cable version:
Installation in P (pump) or MP1 (preload valve) in connection with actual pressure value input "F".
– Using an external pressure transducer:
Installation in the P1 line (preferably close to the actuator) and electrical connection via the central connector.
Using a preload valve:
Connection of the pressure transducer to P1 or MP1.

Notice:

The actual pressure value at port B must not be less than 10 bar for more than 10 minutes (lubrication).

Schematic diagram : Actuating system supplied externally

1)The use of an anti-cavitation valve (check valve with 0.2 bar spring) is essential in order to prevent dry-running in the error case.
2)Pressure transducer (see table)
3)Maximum pressure limitation must be provided by the customer.
4)Observe upper limit for external pilot oil pressure (see operating instructions); recommendation 20 bar absolute.

Pressure transducer

Mounting options

Comment

HM 20-2X/315-F-C13-0.5 (cable version)

P

Only in connection with actual pressure value input "F"

HM 20-2X/...-.-K35 (connector version)

P1

Preferably close to the actuator

Notes on external supply:

  • In the case of an actuating system with external supply, the pump adjustment will - in case of voltage failure - not switch to zero stroke but to the negative stop (displacement of 100 % flow from the system to the tank).
  • With an active fault message, it is imperative that the machine control reacts (e. g. switching off the drive motor of the pump, interrupting the external supply of the actuating system).
  • The command values for pressure and flow must always be greater than zero (pcommand ≥ 3 bar, αcommand ≥ 5 %) as due to drift or tolerances, there is no exact "zero" pressure or "zero" swivel angle. Under unfavorable conditions, smaller command value presettings can lead to cavitation.
  • The actual pressure value must not be less than 10 bar for more than 10 minutes (lubrication).

Electrical connection

X1, central connection

Assignment of connector or mating connector and cable set

Pin

Signal

Description

Signal direction

Type of signal

Allocation in the cable set (accessories)

1

+ UB

Voltage supply

IN

24 VDC

1

Supply line 3 x 1.0 mm2

2

0 V = L0

Reference potential for the voltage supply

2

PE

Earth

Earthing connection for the electronics

green/yellow

3

Fault

Signals faults, e.g. cable break command / actual values, controller monitoring (logic 0 = error)

OUT

logic 24 V

white

Supply line 10 x 0.14 mm2 shielded (one end of the shield must be connected to the control)

4

M0

Reference potential for analog signals

yellow

5

αCommand

Swivel angle command value

IN

analog ±10 V

green

6

αActual

Actual swivel angle value, normalized

OUT

analog ±10 V

Violet

7

pCommand

Pressure command value

IN

analog 0 … 10 V

pink

8

pActual

Actual pressure value, normalized

OUT

analog 0 … 10 V

1)​

red

9

Function dependent on electronic type and additional function, see below

brown

10

Actual pressure value H

Actual pressure value input: Signal level depends on pos. 15 in the ordering code. With version "F" (0.5 … 5 V) reserved

IN

analog

black

11

Actual pressure value L

analog

blue

n.c.

gray

Functions at pin 9

Pin

Additional function

Function dependent on pos. 7 of the ordering code (order, see ordering code)

Signal direction

Type of signal

9

"A"

Selecting a different oil volume adjustment (switch TD)

IN

logic 24 V

"B"

Power limitation active

OUT

logic 24 V

"C"

Command value of power limitation

IN

analog 0 … 10 V

"D"

Switch off pressure controller

IN

logic 24 V

1)When using a pressure transducer with raised zero point (e. g. 4 ... 20 mA), a voltage of –1 ... –2.5 V will be output in case of a cable break.

X2, connection of pressure transducer HM 20

Pin

Signal HM 20

1

OUT, +UB

2

n.c.

3

Reference L0

4

IN, analog, 0.5 … 5 VDC

5

n.c.

Notice:

Mating connectors, separate order, see "Accessories"

Dimensions

Installation orientation "0"

Size 18 … 100

(Shaft design "S”; without through-drive “N00”; representation Size 100)
Dimensions in mm

Size

Version "0479" and "0487"

A1

A3 1)

A4

A5

A6

A6 I

A6 II

A8 I

A8 II

A8 III

A9

A10

A11

Z

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

1812019815863178631152331251001708100G1/4
2812820815863195801152431351151948100G1/4
4513421815863205901152531451252198100G1/4
71146232158632541041502671591502578100G1/4
100151237158632471001472721641503178100G1/4
1)Version "0000"

1

Preload valve (optional)

2

Pilot control valve attachment with clockwise direction of rotation

3

Pilot control valve attachment with counterclockwise direction of rotation

4

Space required to remove the mating connector

5

Port X2 (pressure transducer HM 20) with actual pressure value input "F"

Notice:

Dimensions base pump (axial piston variable displacement pump A10VSO.../31) see data sheet 92711.

Installation orientation "2"

Size 18 … 100

(Shaft design "S”; without through-drive “N00”; representation Size 100)
Dimensions in mm

Size

Version "0479" and "0487"

A1

A3

A4

A5

A6

A6 I

A6 II

A8 I

A8 II

A8 III

A9

A10

A11

Z

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

181001161586317863115151125100253860G1/4
281081271586319580115162135115263860G1/4
451141371586320590115172145125278860G1/4
7112615115863254104150186159150306860G1/4
10013115615863247100147191164150373860G1/4

1

Preload valve (optional)

2

Pilot control valve attachment with clockwise direction of rotation

3

Pilot control valve attachment with counterclockwise direction of rotation

4

Space required to remove the mating connector

5

Port X2 (pressure transducer HM 20) with actual pressure value input "F"

Notice:

Dimensions base pump (axial piston variable displacement pump A10VSO.../31) see data sheet 92711.

Combination pumps

1

Main pump

2

Attachment pump

Attachment pump

Main pump

A10VSO 18

A10VSO 28

A10VSO 45

A10VSO 71

A10VSO 100

A1

A2

A3

A4

A1

A2

A3

A4

A1

A2

A3

A4

A1

A2

A3

A4

A1

A2

A3

A4

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

A10VSO 18

145

182

349

399

164

204

349

399

184

229

374

424

217

267

412

462

275

338

483

533

A10VSO 28

164

204

368.5

410

184

229

393.5

435

217

267

431.5

473

275

338

502.5

544

A10VSO 45

184

229

413

453

217

267

451

491

275

338

522

562

A10VSO 71

217

267

484

524

275

338

555

595

A10VSO 100

275

338

613

664

Ports

Size

18

28

45

71

100

B

Working line (SAE J518)

1)

Size

3/4"

3/4"

1"

1"

1 1/4"

Mounting thread (DIN 13)

M10 x 1.5; 17 deep

M14 x 2; 19 deep

Maximum pressure

2)

bar

350

S

Suction line (SAE J518)

1)

Size

1"

1 1/4"

1 1/2"

2"

2 1/2"

Mounting thread (DIN 13)

M10 x 1.5; 17 deep

M12 x 1.75; 20 deep

M12 x 1.75; 17 deep

Maximum pressure

2)

bar

10

1)Dimensions according to SAE J518 only, metric mounting thread deviating from the standard.
2)Application-specific short-time pressure peaks may occur. Please observe when selecting measuring devices and fittings. Specified pressures are in bar absolute.

Dimensions in mm

Notes regarding size 71:

  • With pressure connection B, two SAE mounting connections rotated by 90° are available. SAE 1 1/4" standard pressure series, 3000 psi, for pressures up to 250 bar or SAE 1" standard pressure series, 5000 psi, for pressures up to 350 bar.
  • For operating pressures exceeding 250 bar, the pressure flange SAE 1" must be used.

Through-drives

"KD3"

Flange ISO 100, 2-hole for the attachment of

  • SYDFE.-2X (NG28 and 45, flange "A")
  • A10VSO..31 (NG28 and 45, flange "A", see data sheet 92711)

Dimensions in mm

1

Hub 7/8"

2

Hub 1"

3

Up to pump mounting face

Size

A1

A2

A3

A4

A5

A6

mm

mm

mm

mm

mm

2820417.841.7--M12 x 1.75; 14 right through
4522917.941.718.446.7M12 x 1.75; 14 right through
7126720.344.120.849.1M12 x 1.75; 20 deep
1003381841.918.245.9M12 x 1.75; 20 deep

Notice:

Sectional presentation with examples for hubs (order number for hubs see "hubs for through-drives")

"KD5"

Flange ISO 125, 2-hole for the attachment of

  • SYDFE.-2X (NG71 and 100, flange "A")
  • A10VSO..31 (NG71 and 100, flange "A", see data sheet 92711)

Dimensions in mm

1

Hub 1 1/4"

2

Hub 1 1/2"

3

Up to pump mounting face

4

Not NG71

Size

A1

A2

A3

A4

A5

A6

mm

mm

mm

mm

mm

7126721.858.6--M16 x 2; right through
10033819.556.410.565M16 x 2; right through

Notice:

Sectional presentation with examples for hubs (order number for hubs see "hubs for through-drives")

"KC1"

Flange SAE 82-2 (SAE A, 2-hole) for the attachment of

  • SYDFE.-2X (NG18, flange "C")
  • A10VSO..31 (NG18, flange "C", see data sheet 92711)
  • PGF2 (shaft "J", flange "U2", see data sheet 10213)
  • PGH2 and PGH3 (shaft "R", flange "U2", see data sheet 10223)
  • AZPF (shaft "R", front cover "R", see data sheet 10089)

Dimensions in mm

1

Hub 5/8"

2

Hub 3/4"

3

Up to pump mounting face

Size

A1

A2

A3

A4

mm

mm

mm

181824043M10; 14.5 deep
282043947M10; 16 deep
4522940.553M10; 16 deep
712674061M10; 20 deep
1003384065M10; 20 deep

Notice:

Sectional presentation with examples for hubs (order number for hubs see "hubs for through-drives")

"KC3"

Flange SAE 101-2 (SAE B, 2-hole) for the attachment of

  • SYDFE.-2X (NG28 and 45, flange "C")
  • A10VO..31 (NG28 and 45, flange "C", see data sheet 92701)
  • PGF3 (shaft "J", flange "U2", see data sheet 10213)
  • PGH4 (shaft "R", flange "U2", see data sheet 10223)

Dimensions in mm

1

Hub 7/8"

2

Hub 1"

3

Up to pump mounting face

4

Not NG28

Size

A1

A2

A3

A4

A5

A6

A7

mm

mm

mm

mm

mm

mm

2820441.717.847--M12; right through
4522941.717.95318.446.7M12; 18 deep
7126741.720.36120.849.1M12; 20 deep
10033841.9186518.246.6M12; 20 deep

Notice:

Sectional presentation with examples for hubs (order number for hubs see "hubs for through-drives")

"KC5"

Flange SAE 127-2 (SAE C, 2-hole) for the attachment of

  • SYDFE.-2X (NG71 and 100, flange "C")
  • A10VO..31 (NG71 and 100, flange "C", see data sheet 92701)
  • PGH5 (shaft "R", flange "U2", see data sheet 10223)

Dimensions in mm

1

Hub 1 1/4"

2

Hub 1 1/2"

3

Up to pump mounting face

4

Not NG71

Size

A1

A2

A3

A4

A5

A6

A7

mm

mm

mm

mm

mm

mm

7126755.517.961--M16; 18 deep
1003385717.965865M16; 25 deep

Notice:

Sectional presentation with examples for hubs (order number for hubs see "hubs for through-drives")

Project planning information

  • Always shield command and actual value cables.
  • The distance to aerial lines or radios must be at least 1 m.
  • Do not lay signal lines close to power lines.
  • For amending notes on the SY(H)DFE control system, see the operating instructions.

Accessories

Hubs for through-drives

Hubs for the combination of single pumps or the combination of SYDFE with other pumps. Observe that the attachment pump has a splined shaft SAE J744 with the specified diameter.

The following conditions apply to the attachment pumps listed in the table:

  • SYDFE and A10VSO with shaft "S" or "R"
  • Internal gear pump PGH with shaft "R", flange "U2", see data sheet 10223
  • Internal gear pump PGF3 with shaft "J", flange "U2", see data sheet 10213
  • External gear pump AZPF with shaft "R", front cover "R", see data sheet 10089

Observe that the through-drive of the main pump and the flange of the attachment pump (see type key pump) are identical. Check in the current data sheet of the gear pump whether the shaft ends have the specified dimensions.

Main pump SYDFE or A10VSO...

Attachment pump

Size 18

Size 28

Size 45

Size 71

Size 100

Ø shaft

Pump type (examples)

R902436099

R902436199

R902436100

R902436200

R902436201

3/4" 19-4

(SAE A-B)

SYDFE-2X, A10VSO..31
Size 018 shaft "S"

R902436098

R902436084

R902436083

R902436101

7/8" 22-4

(SAE B)

SYDFE-2X, A10VSO..31
Size 028 shaft "R"; PGF3

R902436103

R902436104

R902436105

1" 25-4

(SAE B-B)

SYDFE-2X, A10VSO..31
Size 045 shaft "R"; PGH4

R902436085

R902436086

1 1/4" 32-4

(SAE C)

SYDFE-2X, A10VSO..31
Size 071 shaft "R"

R910943565

1 1/2" 38-4

(SAE C-C)

SYDFE-2X, A10VSO..31
Size 100 shaft "S"; PGH5

R910943528

R910986299

R910943529

R91094345

R910943560

5/8" 16-4

(SAE A)

1PF2G2, PGF2,

PGH2, PGH3, AZPF

Torsionally flexible couplings for attachment to a standard electric motor

Motor

SYDFE.-2X

Frame size/characteristic

Shaft diameter

NG18

Shaft "S", 3/4”

NG28

Shaft "S" or "R", 7/8″

NG45

Shaft "S" or "R", 1″

100/0

112/0

28

R901038012

R901038017

132/0

38

R900704699

R901012344

R900772898

160/0

42

R900726977

R900991864

R900994283

180/0

48

R900032918

R900062159

200/0

55

R901038026

R901038025

225/0

60

R900750847

R901066409

250/0

65

R900988348

Motor

SYDFE.-2X

Frame size/characteristic

Shaft diameter

NG71

Shaft "S" or "R", 1 1/4"

NG100

Shaft "S", 1 1/2"

160/0

42

R900228413

180/0

48

R900240468

R900242567

200/0

55

R901038021

R901104689

225/0

60

R900228375

R901050508

250/0

65

R900986404

R901046864

280/0

75

R900218487

R901055216

315/0

80

R901046894 1)

1)Up to 40 °C

Mating connectors for valves with round connector, 11-pole + PE, shielded, with assembled connection line

12P N11 +

Mating connectors for valves with round connector, 11-pole + PE, shielded, with assembled connection line

12P N11 +

  • For valves with round connector according to EN 175201-804, 11-pole + PE

Pressure transducer for hydraulic applications

HM20-2X

Pressure transducer for hydraulic applications

HM20-2X

  • Component series 2X
  • Maximum operating pressure 630bar
  • Pressure ratings 10, 50, 100, 160, 250, 315, 400 and 630 bar
  • cULus-listed

Compact power supply units

VT‑NE30‑2X, VT‑NE31‑1X

Compact power supply units

VT‑NE30‑2X, VT‑NE31‑1X

  • Component series 1X and 2X

Accessories

Material number

Data sheet

Mating connector 12-pole for central connection X1 without cable (assembly kit)

R900884671

08006

Mating connector 12-pole for central connection X1 with cable set 2 x 5 m

R900032356

Mating connector 12-pole for central connection X1 with cable set 2 x 20 m

R900860399

Pressure transducer HM 20-2X, measurement range 315 bar (4 ... 20 mA)

R901342029

30272

Pressure transducer HM 20-2X, measurement range 315 bar (0.1 ... 10 V)

R901342030

30272

Pressure transducer HM 20-2X, measurement range 315 bar (0.5 ... 5 V) with 0,5 m cable

R901342038

30272

Test device VT-PDFE-1-1X/V0/0

R900757051

29689-B

Compact power supply unit VT-NE32-1X

R90080049

29929

Downloads

Proportional-Wegeventile direktgesteuert, mit elektrischer Wegrückführung als Vorsteuerventil für Regelsysteme SY(H)DFE.
Data Sheet | RD29016 | 2021-03-01 | German | PDF | 944k

Product Groups: Electro-hydraulic control systems
Typ VT-DFP.
Proportional directional valves, direct operated, with electrical position feedback as pilot control valve for control systems SY(H)DFE.
Data Sheet | RE29016 | 2021-03-01 | English, United States | PDF | 949k

Product Groups: Electro-hydraulic control systems
Type VT-DFP.
Pressure and flow control system, Operating instructions
Manual | RE30012-B | 2010-09-13 | English | PDF | 2.3MB

Product Groups: Electro-hydraulic control systems
SYDFEE...2X, ...3X, SYHDFEE...1X
Druck- und Förderstrom-Regelsystem, Betriebsanleitung
Manual | RD30012-B | 2010-09-13 | German | PDF | 2.3MB

Product Groups: Electro-hydraulic control systems
SYDFEE...2X, ...3X, SYHDFEE...1X
Druck- und Förderstrom-Regelsystem
Data Sheet | RD30030 | 2021-09-01 | German | PDF | 1.6MB

Product Groups: Electro-hydraulic control systems
Typ SYDFE1, SYDFEE, SYDFED, SYDFEF
Система регулирования давления и расхода
Data Sheet | R-RS30030 | 2022-02-28 | Russian | PDF | 1.5MB

Product Groups: Electro-hydraulic control systems
Тип SYDFE1, SYDFEE, SYDFED, SYDFEF
Pressure and flow control system
Data Sheet | RE30030 | 2021-09-01 | English, United States | PDF | 1.6MB

Product Groups: Electro-hydraulic control systems
Type SYDFE1, SYDFEE, SYDFED, SYDFEF

Мы предлагаем следующие способы доставки товара:

Самовывоз из пункта выдачи

Самостоятельное получение заказа в пункте выдачи. Дата и время получения заранее согласуется с менеджером магазина.
Отгрузка товара юридическим лицам осуществляется только при наличии печати или правильно оформленной и заполненной доверенности, наличии паспорта получателя.


Курьерская доставка по Москве

Доставка по адресу покупателя или до пункта приема транспортной компании в г. Москве. Дата и время доставки заранее согласуется с менеджером магазина.

Доставка транспортной компанией по России

Доставка транспортной компанией по России до пункта выдачи транспортной компании или до конечного адреса покупателя. 
 

Для расчета коммерческого предложения или получения счета на поставку оборудования и программного обеспечения Bosch Rexroth оставьте заявку в форме ниже или свяжитесь с отделом продаж по телефону +7 495 137-07-02 или электронной почте sale@boschrexroth-russia.ru. Мы гарантируем оперативный ответ на ваш запрос и предоставление наилучших условий от официального поставщика Bosch Rexroth. 

Специалист по решениям Bosch Rexroth:

  • Окажет профессиональную консультацию.
  • Сообщит вашу цену на продукцию.
  • Сообщит информацию об актуальных акциях и скидках.
  • Подскажет ближайшее к вам отделение с наличием нужной продукции.
  • Согласует с вами возможную дату и время доставки.

Запрос цены или КП

Запрос цен, наличия или консультация
Пришлем актуальную информацию по ценам, скидкам, наличию товара на складе и срокам поставки
НовостиВсе новости
Bosch Rexroth открывает новые возможности в управлении машинами и подключении к IoT

Bosch Rexroth предлагает одну из самых производительных систем ЧПУ на рынке. Компания является лидером в области автоматизации и устанавливают стандарты в этой области. От датчиков и сервоприводов до революционной новой платформы, Bosch Rexroth предлагает широкий спектр решений для автоматизации. ..

16 Февраля, 2024
Bosch Rexroth и TotalEnergies объединяют свои усилия для продвижения альтернативных и экологичных гидравлических жидкостей

Bosch Rexroth и TotalEnergies (французская нефтегазовая компания) 18 декабря 2023 года подписали соглашение сотрудничестве, направленном на разработку, внедрение и маркетинг гидравлических жидкостей на водной основе, с акцентом на экологичность, огнестойкость и производительность. Данный союз отр..

11 Января, 2024
Bosch Rexroth представляет Интеллектуальный функциональный набор для обработки данных Smart Function Kit for Handling

Компания Bosch Rexroth является одним из ведущих мировых производителей и поставщиков технологий и услуг в области промышленной автоматизации. Это производитель рад представить вам свой интеллектуальный функциональный набор для обработки данных. Это инновационное оборудование, с помощью которого п..

4 Декабря, 2023
Бренд Bosch Rexroth представил миру свою разработку - оборудование IndraDrive CDB02 - BASIC для двухосевого блока управления

Bosch Rexroth, являясь ведущим производителем промышленного оборудования, не стоит на месте и разрабатывает новое оборудование. Одним из изобретений этой компании является IndraDrive CDB02 - BASIC. Это двухосевой блок управления, который предназначен для использования в различных промышленных сект..

1 Декабря, 2023
Bosch Rexroth: высокоскоростной асинхронный двигатель 1MB140 

Производитель Bosch Rexroth представил свою разработку - высокоскоростной асинхронный двигатель 1MB140. Этот продукт обладает рядом уникальных характеристик и предназначен для различных применений в промышленности. Основным назначением двигателя 1MB140 является обеспечение высокой скорости вращ..

30 Ноября, 2023
Bosch Rexroth рассказывает о характеристиках электрогидравлических насосов

Bosch Rexroth представляет электрогидравлические насосы, которые объединяют в себе преимущества электрической и гидравлической технологий. Данные насосы могут использоваться в различных отраслях промышленности, включая машиностроении, автомобильной промышленности, энергетике и других. Основная ..

29 Ноября, 2023
Bosch Rexroth представил серию высокоэффективных синхронных моментных двигателей МВТ130 

Синхронные моментные двигатели МВТ130 применяются в различных отраслях промышленности: машиностроение, автомобильной и энергетической промышленности. Это оборудование используют как дополнение к насосам, компрессорам, приводам конвейеров и другим механизмам, требующим точного управления и высокой ..

28 Ноября, 2023
Bosch Rexroth: надежные и эффективные героторные насосы подходят для решения для множества задач

Героторные насосы Bosch Rexroth — это инновационное оборудование, которое обеспечивает эффективную работу в различных областях промышленности. Они являются незаменимым компонентом в системах гидравлического привода и обеспечивают надежную и плавную работу механизмов. Принцип работы герото..

27 Ноября, 2023
Для эффективной работы гидравлических систем Bosch Rexroth представляет баллонный аккумулятор HAB2 

Баллонный аккумулятор HAB2 производства компании Bosch Rexroth — это инновационное оборудование, предназначенное для оптимизации работы гидравлических систем и обеспечения более эффективного использования энергии. Баллонный аккумулятор HAB2 выполняет несколько важных функций. Во-первых, с..

24 Ноября, 2023
Bosch Rexroth: инновационное решение для удобства и эффективности работы - выдвижная клавиатура VAK40 

Торговая марка Bosch Rexroth, является одним из мировых лидеров в области промышленной автоматизации, и представляет свою разработку - выдвижную клавиатуру VAK40. Это инновационное устройство, которое обеспечивает удобную и эффективную работу операторов в промышленных условиях. Установить выдви..

23 Ноября, 2023
Bosch Rexroth: инновационные функции и простая установка дисплея 19" VDP60

Бренд Bosch Rexroth рад представить свою разработку - дисплей 19" VDP60, который обещает стать настоящим прорывом в мире технологий. Этот дисплей не только показывает изображения высокого качества, но и предлагает ряд функций, которые помогут решить множество задач. Одним из главных свойст..

22 Ноября, 2023
Rexroth: Шестеренные насосы с внешним зацеплением – надежное решение для эффективной работы в различных отраслях

Компания Rexroth представляет шестеренные насосы с внешним зацеплением, которые являются необходимым прибором в области гидравлики. Они выполняют важную задачу – обеспечивают надежную и эффективную работу гидравлических систем в различных отраслях промышленности. Эти насосы нашли применен..

21 Ноября, 2023

Нет отзывов об этом товаре.

Написать отзыв

Рейтинг